Analytical calculation for the solid angle subtended at an arbitrarily positioned point source by an ellipse - Paper 38

The geometrical solid angle can be used to calibrate radiation detectors or to determine the activity of radioactive sources. In the present work, we introduce a direct analytical method for calculating the solid angle subtended at an arbitrarily positioned point source by a closed contour (ellipse). The validity of the derived analytical expressions was successfully confirmed by the comparison with some published data (Numerical Method). Direct mathematical expressions to calculate the geometrical solid angle subtended by an elliptical disk detector with respect to arbitrarily positioned radiating point sources have been derived. The agreement between the calculated and the published solid angle values is excellent; the discrepancies were (0.0%). This means that the present approach is efficient and sufficiently powerful to evaluate the geometrical efficiency of the elliptical disk detectors. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Efficiency Calibration of 4{pi} NaI(Tl) Gamma-ray Detectors for Plane Sources - Paper 130

4{pi} NaI(Tl) detectors are useful for low level gamma activity measurements due to the near 4{pi} solid angle that can be obtained with them. An analytical theoretical approach is presented here to calculate the absolute efficiencies for this type of detectors. The approach depends on the accurate calculation of two important factors; the path length, d, the photon traverses within the active volume of a gamma detector, and the geometrical solid angle,{Omega}, subtended by the source to the detector at the point of entrance. These two factors are theoretically derived through a straightforward analytical approach. In this work, this model is extended to an isotropic radiating point source, and a thin circular disk source. The results of the present absolute efficiency values were compared with the experimental and M.C. method works reported in the literature. The present theoretical and the experimental efficiency values are in good agreement. The present approach offers a good method to calibrate 4{pi} NaI(Tl) detectors over a large energy range without the need for standard sources, as is the case for experimental methods, nor optimization of detector parameters as for Monte Carlo simulations. Discrepancies with experimental results are reduced to lower than 4%. (author)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗