Search NASA⌕ Search

Engineering topics

Abbot, R. I.

Publications and source records attributed to Abbot, R. I..

Centimeter-level relative positioning with GPS

Although the Global Positioning System (GPS) was designed primarily for real-time navigation and positioning applications at the decameter level of accuracy, the GPS has been used to determine all three relative position coordinates of fixed points with centimeter-level accuracy, when the distance between the points has been of the order of 10 km. For intersite distances less than 1 km the uncertainty is about 3 mm, and for distances greater than 10 km the uncertainty in each coordinate is about 1-2 ppm of the distance. These results have been obtained with commercially available production equipment (Macrometer model V-1000 interferometric surveyors) operated by regular surveying personnel under real field conditions, not just by university scientists under ideal laboratory conditions. Techniques that promise to reduce the uncertainty to 0.1 ppm for distances greater than 10 km are being developed.

Counselman, C. C., III↗

Astrometric observations of Saturn's satellites from McDonald Observatory, 1972

Observations of Saturn's satellites have been reduced by means of secondary reference stars obtained by reduction of Palomar Sky Survey plates. This involved the use of 29 SAO stars and plate overlap technique to determine the coordinates of 59 fainter stars in the satellite field. Fourteen plate constants were determined for each of the two PSS plates. Comparison of two plate measurement and reduction techniques on the satellite measures appears to demonstrate the existence of a serious background gradient effect and the utility of microdensitometry to eliminate this error source in positional determinations of close satellites.

Abbot, R. I.↗

Astrometric observations of Saturn's satellites from McDonald Observatory, 1972

Observations of Saturn's satellites were reduced by means of secondary reference stars obtained by reduction of Palomar Sky Survey (PSS) plates. This involved the use of 39 SAO stars and plate overlap technique to determine the coordinates of 59 fainter stars in the satellite field. Fourteen plate constants were determined for each of the two PSS plates. Comparison of two plate measurement and reduction techniques on the satellite measurements demonstrate the existence of a serious background gradient effect and the utility of microdensitometry to eliminate this error source in positional determinations of close satellites.

Abbot, R. I.↗