Search NASA⌕ Search

Engineering topics

Abbott, J. M.

Publications and source records attributed to Abbott, J. M..

24 records · Page 2

Aeroacoustic performance of scale model sonic inlets

A low speed wind tunnel was used to evaluate the inflight aeroacoustic performance of several single- and multiple-passage sonic inlets. Takeoff and approach geometries were tested, and the effects of inlet lip and diffuser design were determined. Results indicate that the single passage geometries, in particular a cylindrical centerbody takeoff geometry and a bulb shaped centerbody approach geometry, provide the highest level of aeroacoustic performance. Increasing inlet lip contraction ratio extends the maximum incidence angle for attached lip flow, while increasing inlet diffuser length results in higher total pressure recovery for a given amount of noise suppression.

Abbott, J. M.↗

Aeroacoustic performance of scale model sonic inlets

Various means can be used to vary engine inlet throat areas in order to reduce noise generated at takeoff and approach. Low-speed wind-tunnel tests were performed to evaluate the aeroacoustic performance of two takeoff geometries (cylindrical centerbody and bulb-shaped centerbody) and four approach geometries (bulb-shaped centerbody, annular ring, radial vanes, and step diffuser). The effects of inlet internal lip shape and diffuser length on sonic inlet performance were also investigated. It was found that the single-passage geometries, in particular a cylindrical centerbody takeoff geometry and a bulb-shaped centerbody approach geometry, provide the highest level of aeroacoustic performance. Increasing the inlet lip contraction ratio extends the maximum incidence angle for attached lip flow, while increasing the inlet diffuser length increases total pressure recovery for a given amount of noise suppression.

Abbott, J. M.↗

Low-speed wind tunnel tests of a 50.8-centimeter (20-in.) 1.15-pressure-ratio fan engine model

At a typical STOL aircraft takeoff and landing velocity, wind tunnel aerodynamic and acoustic measurements demonstrated that an inlet lip-area contraction ratio of 1.35 was superior to a ratio of 1.26 at high incidence angles. A 17 percent reduction in net thrust and an increase of 9 decibels in sound pressure level at the blade passing frequency resulted from inlet flow separation at an incidence angle of 50 deg with the 1.26-contraction-ratio inlet. Reverse-thrust forces obtained with blade rotation through the feathered angle were 1.8 times larger than with blade rotation through the flat angle. Reverse-thrust force was reduced from 30 to 50 percent and sound pressure level increased from 3 to 7 decibels at the blade passing frequency between the wind-tunnel-off condition and a typical STOL aircraft landing velocity.

Wesoky, H. L.↗

Low-speed wind-tunnel investigation of the aerodynamic and acoustic performance of a translating grid choked flow inlet

The aerodynamic and acoustic performance of a translating grid choked-flow inlet was determined in a low-speed wind tunnel at free-stream velocities of 24, 32, and 45 m/sec and incidence angles of 0, 10, 20, 30, 35, 40, 45, and 50 deg. The inlet was sized to fit a 13.97- centimeter-diameter fan with a design weight flow of 2.49 kg/sec. Measurements were made to determine inlet total pressure recovery, flow distortion, and sound pressure level for both choked and unchoked geometries over a range of inlet weight flows. For the unchoked geometry, inlet total pressure recovery ranged from 0.983 to 0.989 at incidence angles less than 40 deg. At 40 deg incidence angle, inlet cowl separation was encountered which resulted in lower values of pressure recovery and higher levels of fan broadband noise. For the choked geometry, increasing total pressure losses occurred with increasing inlet weight flow that prevented the inlet from reaching full choked conditions with the particular fan used. These losses were attributed to the high Mach number drag rise characteristics of airfoil grid. At maximum attainable inlet weight flow, the total pressure recovery at static conditions was 0.935. The fan blade passing frequency and other fan generated pure tones were eliminated from the noise spectrum, but the broadband level was increased.

Abbott, J. M.↗

Low-speed wind tunnel investigation of the aerodynamic and acoustic performance of a translating-centerbody choked-flow inlet

Low-speed wind-tunnel tests were conducted to determine the effects of free-stream velocity and incidence angle on the aerodynamic and acoustic performance of a translating centerbody choked-flow inlet. The inlet was sized to fit a 13.97 cm diameter fan with a design weight flow of 2.49 kg/sec. Performance was determined at free-stream velocities to 45 meters per second and incidence angles of 0 deg to 50 deg. The inlet was operated in both the choked and unchoked modes over a range of weight flows. Measurements were made of inlet total pressure recovery, flow distortion, surface static pressure distribution, and fan noise suppression. In the choked mode, increasing incidence angle tended to reduce the amount of inlet noise suppression for a given amount of inlet suction. This tendency was overcome by applying sufficient inlet suction to increase the flow Mach number. At 45 meters per second free-stream velocity, at least 22 decibels of suppression were measured at 35 deg incidence angle with a total pressure recovery of 0.985.

Miller, B. A.↗

Aerodynamic and Acoustic Performance of Two Choked-Flow Inlets Under Static Conditions

Tests were conducted to determine the aerodynamic and acoustic performance of two choking flow inlets under static conditions. One inlet choked the flow in the cowl throat by an axial translation of the inlet centerbody. The other inlet employed a translating grid of airfoils to choke the flow. Both inlets were sized to fit a 13.97 cm diameter fan with a design weight flow of 2.49 kg/sec. The inlets were operated in both the choked and unchoked modes over a range of weight flows. Measurements were made of inlet pressure recovery, flow distortion, surface static pressure distribution, and fan noise suppression. Choking of the translating centerbody inlet reduced blade passing frequency noise by 29 db while yielding a total pressure recovery of 0.985. Noise reductions were also measured at 1/3-octave band center frequencies of 2500, 5000, and 20,000 cycles. The translating grid inlet gave a total pressure recovery of 0.968 when operating close to the choking weight flow. However, an intermittent high intensity noise source was encountered with this inlet that precluded an accurate measurement of inlet noise suppression.

Miller, B. A.↗