Design of Sample Holder for Plutonium Coupon Studies

In order to gain better understanding of the plutonium (Pu) corrosion behaviors and reaction kinetics, it is imperative that coupon experiments must be performed on well-defined surfaces. The reactions at the samples’ surfaces have to be properly monitored in terms of reactive gaseous pressures and temperatures. The pressure can be measured by using a pressure gauge, the temperature can be detected with calibrated thermal couples and/or pyrometric camera. These devices do not interfere with the chemistry of the surface reaction. However, to obtain information from the surface reaction, the aggressively machined edge and the back side of the Pu coupons need to be shielded from the applied gases. The coupons are typically made to 5/8 inch in diameter and 0.065 inch in thickness. To this end, a sample holder was designed which can seal the machined edge and the back side of coupons from the exposed gases, thus allowing proper surface reaction. The holder design was fabricated and had been tested with several coupon samples. We have achieved perfect sealing of the machined edge and the back side of the coupons, even when the coupons’ thicknesses are vastly different than the nominal thickness for which the sample holders were fabricated for. This write-up is to document the design of the holder and provide a description of the procedures to properly put the components together.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental comparison of icing cloud instruments

Icing cloud instruments were tested in the spray cloud Icing Research Tunnel (IRT) in order to determine their relative accuracy and their limitations over a broad range of conditions. It was found that the average of the readings from each of the liquid water content (LWC) instruments tested agreed closely with each other and with the IRT calibration; but all have a data scatter (+ or - one standard deviation) of about + or - 20 percent. The effect of this + or - 20 percent uncertainty is probably acceptable in aero-penalty and deicer experiments. Existing laser spectrometers proved to be too inaccurate for LWC measurements. The error due to water runoff was the same for all ice accretion LWC instruments. Any given laser spectrometer proved to be highly repeatable in its indications of volume median drop size (DVM), LWC and drop size distribution. However, there was a significant disagreement between different spectrometers of the same model, even after careful standard calibration and data analysis. The scatter about the mean of the DVM data from five Axial Scattering Spectrometer Probes was + or - 20 percent (+ or - one standard deviation) and the average was 20 percent higher than the old IRT calibration. The + or - 20 percent uncertainty in DVM can cause an unacceptable variation in the drag coefficient of an airfoil with ice; however, the variation in a deicer performance test may be acceptable.

Olsen, W.↗