Search NASA⌕ Search

Engineering topics

Afanaciev, K.

Publications and source records attributed to Afanaciev, K..

A search for $$\upmu ^+ \rightarrow \textrm{e}^+ \upgamma $$ with the first dataset of the MEG II experiment

Abstract The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay$$\upmu ^+ \rightarrow {\textrm{e}}^+ \upgamma $$ μ + → e + γ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of$${\mathcal {B}} (\upmu ^+ \rightarrow {\textrm{e}}^+ \upgamma ) < 7.5 \times 10^{-13}$$ B ( μ + → e + γ ) < 7.5 × 10 - 13 (90% CL). The combination of this result and the limit obtained by MEG gives$${\mathcal {B}} (\upmu ^+ \rightarrow {\textrm{e}}^+ \upgamma ) < 3.1 \times 10^{-13}$$ B ( μ + → e + γ ) < 3.1 × 10 - 13 (90% CL), which is the most stringent limit to date. A ten-fold larger sample of data is being collected during the years 2022–2023, and data-taking will continue in the coming years.

Physics↗

Operation and performance of the MEG II detector

Abstract The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the$$\upmu ^+ \rightarrow {\textrm{e}}^+ \upgamma $$ μ + → e + γ decay down to$$\sim 6 \times 10^{-14}$$ ∼ 6 × 10 - 14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.

Physics↗

Performance and Molière radius measurements using a compact prototype of LumiCal in an electron test beam

A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear e \(^{+}\) e \(^{-}\) collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1–5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Molière radius at 5 GeV was determined to be (8.1 ± 0.1 (stat) ± 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 ± 0.1) mm. The dependence of the effective Molière radius on the electron energy in the range 1–5 GeV was also studied. Good agreement was obtained between data and MC simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗