Search NASA⌕ Search

Engineering topics

Agnes, P.

Publications and source records attributed to Agnes, P..

At least 19 records

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ∼ 50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (∼ 40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of 83m Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

47 OTHER INSTRUMENTATION↗

Search for dark matter annual modulation with DarkSide-50

Dark matter may induce an event in an Earth-based detector, and its event rate is predicted to show an annual modulation as a result of the Earth’s orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above 40 eV ee , the lowest threshold ever achieved in such a search. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches

Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.

Dark Matter detectors (WIMPs, axions, etc.)↗

Constraints on directionality effect of nuclear recoils in a liquid argon time projection chamber

The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils produced in a target material from the WIMP elastic scattering. The experimental identification of the direction of the WIMP-induced nuclear recoils is a crucial asset in this field, as it enables unmistakable modulation signatures for dark matter. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity in argon dual-phase time projection chambers (TPC), that are widely considered for current and future direct dark matter searches. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud. Data were taken with nuclear recoils of known directions and kinetic energy of 72 keV, which is within the range of interest for WIMP-induced signals in argon. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio R of the initial ionization cloud is $R < 1.072$ with 90 % confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of cosmogenic activation above ground for the DarkSide-20k experiment

The activation of materials due to exposure to cosmic rays may become an important background source for experiments investigating rare event phenomena. DarkSide-20k, currently under construction at the Laboratori Nazionali del Gran Sasso, is a direct detection experiment for galactic dark matter particles, using a two-phase liquid-argon Time Projection Chamber (TPC) filled with 49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39 Ar. Despite the outstanding capability of discriminating γ / β background in argon TPCs, this background must be considered because of induced dead time or accidental coincidences mimicking dark-matter signals and it is relevant for low-threshold electron-counting measurements. Here, the cosmogenic activity of relevant long-lived radioisotopes induced in the experiment has been estimated to set requirements and procedures during preparation of the experiment and to check that it is not dominant over primordial radioactivity; particular attention has been paid to the activation of the 120 t of UAr used in DarkSide-20k. Expected exposures above ground and production rates, either measured or calculated, have been considered in detail. From the simulated counting rates in the detector due to cosmogenic isotopes, it is concluded that activation in copper and stainless steel is not problematic. The activity of 39 Ar induced during extraction, purification and transport on surface is evaluated to be 2.8% of the activity measured in UAr by DarkSide-50 experiment, which used the same underground source, and thus considered acceptable. Other isotopes in the UAr such as 37 Ar and 3 H are shown not to be relevant due to short half-life and assumed purification methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel

Dark matter lighter than 10 GeV / c 2 encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These studies show that DarkSide-LowMass can achieve sensitivity to light dark matter down to the solar neutrino fog for GeV-scale masses and significant sensitivity down to 10 MeV / c 2 considering the Migdal effect or interactions with electrons. Requirements for optimizing the detector’s sensitivity are explored, as are potential sensitivity gains from modeling and mitigating spurious electron backgrounds that may dominate the signal at the lowest energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of isotopic separation of argon with the prototype of the cryogenic distillation plant Aria for dark matter searches

The Aria cryogenic distillation plant, located in Sardinia, Italy, is a key component of the DarkSide-20k experimental program for WIMP dark matter searches at the INFN Laboratori Nazionali del Gran Sasso, Italy. Aria is designed to purify the argon, extracted from underground wells in Colorado, USA, and used as the DarkSide-20k target material, to detector-grade quality. In this paper, we report the first measurement of argon isotopic separation by distillation with the 26 m tall Aria prototype. We discuss the measurement of the operating parameters of the column and the observation of the simultaneous separation of the three stable argon isotopes: ${}^{36}\hbox {Ar}$, ${}^{38}\textrm{Ar}$, and ${}^{40}\textrm{Ar}$. We also provide a detailed comparison of the experimental results with commercial process simulation software. This measurement of isotopic separation of argon is a significant achievement for the project, building on the success of the initial demonstration of isotopic separation of nitrogen using the same equipment in 2019.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for low mass dark matter in DarkSide-50: the bayesian network approach

Abstract We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there is no need to morph signal and background spectra as a function of nuisance parameters. By expressing the problem in terms of Bayesian Networks, we have developed an inference algorithm based on a Markov Chain Monte Carlo to calculate the posterior probability. A clever description of the detector response model in terms of parametric matrices allows us to study the impact of systematic variations of any parameter on the final results. Our approach not only provides the desired information on the parameter of interest, but also potential constraints on the response model. Our results are consistent with recent published analyses and further refine the parameters of the detector response model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A study of events with photoelectric emission in the DarkSide-50 liquid argon Time Projection Chamber

Finding unequivocal evidence of dark matter interactions in a particle detector is a major goal of research in physics. Liquid argon time projection chambers offer a path to probe Weakly Interacting Massive Particles scattering cross sections on nuclei down to the so-called neutrino floor, in a mass range from a few GeV to hundreds of TeV. Based on the successful operation of the DarkSide-50 detector at LNGS, a new and more sensitive experiment, DarkSide-20k, has been designed and is now under construction. A thorough understanding of the DarkSide-50 detector response and, therefore, of all types of events observed in the detector, is essential for the optimal design of the new experiment. In this article, we report on a specific set of events, namely, standard two-pulse scintillation–ionization signals with a third small amplitude pulse, occurring within the 440 μ s data acquisition window of standard events. Some of these events are due to the photoionization of the TPC cathode. We compare our results with those published by collaborations using liquid xenon time projection chambers, which observed a similar phenomenon, and, in particular, with a recent paper by the LUX Collaboration (D.S. Akerib et al. Phys.Rev.D 102, 092004 (2020)) From the measured rate of these events, we estimate for the first time the quantum efficiency of the tetraphenyl butadiene deposited on the DarkSide-50 cathode at wavelengths of around 128 nm, in liquid argon. Also, both experiments observe events likely related to the photoionization of impurities in the liquid. The probability of photoelectron emission per unit length turns out to be an order of magnitude lower in DarkSide-50 than in LUX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the scintillation time response of liquid argon detectors for dark matter search

The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. Herein, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.

47 OTHER INSTRUMENTATION↗

Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50

DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV=c 2 mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows us to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionization yield of electronic recoils down to ~180 eV er , exploiting 37 Ar and 39 Ar decays, and extrapolated to a few ionization electrons with the Thomas-Imel box model. Further, we present a model-dependent determination of the ionization response to nuclear recoils down to ~500 eV nr , the lowest ever achieved in liquid argon, using in situ neutron calibration sources and external datasets from neutron beam experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Separating $${^{39}\hbox {Ar}}$$ from $${^{40}\hbox {Ar}}$$ by cryogenic distillation with Aria for dark-matter searches

Abstract Aria is a plant hosting a $${350}\,\hbox {m}$$ 350 m cryogenic isotopic distillation column, the tallest ever built, which is being installed in a mine shaft at Carbosulcis S.p.A., Nuraxi-Figus (SU), Italy. Aria is one of the pillars of the argon dark-matter search experimental program, lead by the Global Argon Dark Matter Collaboration. It was designed to reduce the isotopic abundance of $${^{39}\hbox {Ar}}$$ 39 Ar in argon extracted from underground sources, called Underground Argon (UAr), which is used for dark-matter searches. Indeed, $${^{39}\hbox {Ar}}$$ 39 Ar is a $$\beta $$ β -emitter of cosmogenic origin, whose activity poses background and pile-up concerns in the detectors. In this paper, we discuss the requirements, design, construction, tests, and projected performance of the plant for the isotopic cryogenic distillation of argon. We also present the successful results of the isotopic cryogenic distillation of nitrogen with a prototype plant.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The novel Mechanical Ventilator Milano for the COVID-19 pandemic

This paper presents the Mechanical Ventilator Milano (MVM), a novel intensive therapy mechanical ventilator designed for rapid, large-scale, low-cost production for the COVID-19 pandemic. Free of moving mechanical parts and requiring only a source of compressed oxygen and medical air to operate, the MVM is designed to support the long-term invasive ventilation often required for COVID-19 patients and operates in pressure-regulated ventilation modes, which minimize the risk of furthering lung trauma. The MVM was extensively tested against ISO standards in the laboratory using a breathing simulator, with good agreement between input and measured breathing parameters and performing correctly in response to fault conditions and stability tests. The MVM has obtained Emergency Use Authorization by U.S. Food and Drug Administration (FDA) for use in healthcare settings during the COVID-19 pandemic and Health Canada Medical Device Authorization for Importation or Sale, under Interim Order for Use in Relation to COVID-19. Furthermore, following these certifications, mass production is ongoing and distribution is under way in several countries. The MVM was designed, tested, prepared for certification, and mass produced in the space of a few months by a unique collaboration of respiratory healthcare professionals and experimental physicists, working with industrial partners, and is an excellent ventilator candidate for this pandemic anywhere in the world

60 APPLIED LIFE SCIENCES↗

Sensitivity of future liquid argon dark matter search experiments to core-collapse supernova neutrinos

Future liquid-argon DarkSide-20k and Argo detectors, designed for direct dark matter search, will be sensitive also to core-collapse supernova neutrinos, via coherent elastic neutrino-nucleus scattering. This interaction channel is flavor-insensitive with a high-cross section, enabling for a high-statistics neutrino detection with target masses of ~50 t and ~360 t for DarkSide-20k and Argo respectively. Thanks to the low-energy threshold of ~0.5 keVnr achievable by exploiting the ionization channel, DarkSide-20k and Argo have the potential to discover supernova bursts throughout our galaxy and up to the Small Magellanic Cloud, respectively, assuming a 11-M progenitor star. In this work, we report also on the sensitivity to the neutronization burst, whose electron neutrino flux is suppressed by oscillations when detected via charged current and elastic scattering. Finally, the accuracies in the reconstruction of the average and total neutrino energy in the different phases of the supernova burst, as well as its time profile, are also discussed, taking into account the expected background and the detector response.

79 ASTRONOMY AND ASTROPHYSICS↗

SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The “standard” EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms (“neutral bremsstrahlung”, NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗