Ship Effect Neutron Measurements And Impacts On Low-Background Experiments

The primary particles entering the upper atmosphere as cosmic rays create showers in the atmosphere that include a broad spectrum of secondary neutrons, muons and protons. These cosmic-ray secondaries interact with materials at the surface of the Earth, yielding prompt backgrounds in radiation detection systems, as well as inducing long-lived activities through spallation events, dominated by the higher-energy neutron secondaries. For historical reasons, the multiple neutrons produced in spallation cascade events are referred to as “ship effect” neutrons. Quantifying the background from cosmic ray induced activities is important to low-background experiments, such as neutrino-less double beta decay. Since direct measurements of the effects of shielding on the cosmic-ray neutron spectrum are not available, Monte Carlo modeling is used to compute such effects. However, there are large uncertainties (orders of magnitude) in the possible cross-section libraries and the cosmic-ray neutron spectrum for the energy range needed in such calculations. The measurements reported here were initiated to validate results from Monte Carlo models through experimental measurements in order to provide some confidence in the model results. The results indicate that the models provide the correct trends of neutron production with increasing density, but there is substantial disagreement between the model and experimental results for the lower-density materials of Al, Fe and Cu.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Simulation Tool Installation and Operation Guide

This document provides information on software and procedures for Monte Carlo simulations based on the Geant4 toolkit, the ROOT data analysis software and the CRY cosmic ray library. These tools have been chosen for its application to shield design and activation studies as part of the simulation task for the Majorana Collaboration. This document includes instructions for installation, operation and modification of the simulation code in a high cyber-security computing environment, such as the Pacific Northwest National Laboratory network. It is intended as a living document, and will be periodically updated. It is a starting point for information collection by an experimenter, and is not the definitive source. Users should consult with one of the authors for guidance on how to find the most current information for their needs.

CRY↗

The Design of an Ultra-Low Background Thermosyphon for the Majorana Demonstrator

The MAJORANA DEMONSTRATOR (MJD) is an ultra-low background neutrinoless double-beta decay (0νββ) experiment that will deploy up to 40 kg of high purity germanium detectors (HPGe). The goal of this experiment is to demonstrate the feasibility of building a detector array with less than 1 event/ton-year in a 4 keV region of interest around the 0νββ signal. HPGe diodes, when used as ionizing radiation detectors, need to be maintained at a temperature close to that of liquid nitrogen (77 K). This work describes the R&D results of a cryogenic system capable of meeting the requirements of low background and the cooling capacity required to successfully operate such a detector system. The MJD germanium detector modules will operate at liquid nitrogen temperature to provide adequate cooling for a full range of HPGe impurity concentrations. This paper shows the experimental results obtained using a two-phase horizontal thermosyphon using liquid nitrogen as the MJD’s cooling system. The cold test shows that the proposed thermosyphon has sufficient cooling power to handle the heat load of an MJD module. Results for the temperature gradient across the thermosyphon, cooling capacity, and design considerations demonstrate that the thermosyphon can effectively remove the calculated heat load of each module of the experiment. The thermosyphon will be bolted to a cold plate from which detector strings will hang. The thermal conductivity of a mockup of the MJD bolted thermal joint is experimentally determined to be below 0.1 K/W.

Detector arrays↗

The MAJORANA experiment: an ultra-low background search for neutrinoless double-beta decay

The observation of neutrinoless double-beta decay would resolve the Majorana nature of the neutrino and could provide information on the absolute scale of the neutrino mass. The initial phase of the Majorana Experiment, known as the Demonstrator, will house 40 kg of Ge in an ultra-low background shielded environment at the 4850' level of the Sanford Underground Laboratory in Lead, SD. The objective of the Demonstrator is to validate whether a future 1-tonne experiment can achieve a background goal of one count per tonne-year in a narrow region of interest around the 76Ge neutrinoless double-beta decay peak.

double-beta decay↗

DESIGN OF A THERMOSIPHON FOR COOLING LOW-BACKGROUND HPGE ARRAYS

ABSTRACT A two-phase nitrogen thermosiphon was developed for the new generation of low-background high-purity germanium (HPGe) arrays. The cooling system for these arrays has to be able to handle the heat load (>20 W) presented by a large detector mass while meeting stringent requirements necessary for low-background systems. The HPGe detector modules should operate as close to liquid nitrogen temperature (<80K) as possible to provide adequate operating conditions for a full range of HPGe impurity concentrations. In addition, exceptional temperature stability (<1 K) is needed to reduce electronic gain shifts due to changes in the front-end electronics operating temperature. In order to meet the background requirements of state-of-the-art systems these arrays are enclosed in passive lead and copper shielding up to 1 m thick. In this paper we present a cooling system for low-background experiments that complies with these stringent geometrical restrictions. Active cooling was integrated via a horizontal thermosiphon that can be fabricated using ultra-pure electroformed copper. It was charged with nitrogen to 434 kPa (63 PSIA) at 292 K, which provided a fill ratio of 10%. The results showed that the thermosiphon can effectively remove in excess of 25 W of heat load.

low-background, thermal conductivity, radiation de↗

Majorana Demonstrator Bolted Joint Mechanical and Thermal Analysis

The MAJORANA DEMONSTRATOR is designed to probe for neutrinoless double-beta decay, an extremely rare process with a half-life in the order of 10 26 years. The experiment uses an ultra-low background, high-purity germanium detector array. The germanium crystals are both the source and the detector in this experiment. Operating these crystals as ionizing radiation detectors requires having them under cryogenic conditions (below 90 K). A liquid nitrogen thermosyphon is used to extract the heat from the detectors. The detector channels are arranged in strings and thermally coupled to the thermosyphon through a cold plate. The cold plate is joined to the thermosyphon by a bolted joint. This circular plate is housed inside the cryostat can. This document provides a detailed study of the bolted joint that connects the cold plate and the thermosyphon. An analysis of the mechanical and thermal properties of this bolted joint is presented. The force applied to the joint is derived from the torque applied to each one of the six bolts that form the joint. The thermal conductivity of the joint is measured as a function of applied force. The required heat conductivity for a successful experiment is the combination of the thermal conductivity of the detector string and this joint. The thermal behavior of the joint is experimentally implemented and analyzed in this study.

Aguayo Navarrete, Estanislao↗

Optimization of the Transport Shield for Neutrinoless Double-beta Decay Enriched Germanium

This document presents results of an investigation of the material and geometry choice for the transport shield of germanium, the active detector material used in 76Ge neutrinoless double beta decay searches. The objective of this work is to select the optimal material and geometry to minimize cosmogenic production of radioactive isotopes in the germanium material. The design of such a shield is based on the calculation of the cosmogenic production rate of isotopes that are known to cause interfering backgrounds in 76Ge neutrinoless double beta decay searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Majorana Experiment

The Majorana collaboration is actively pursuing research and development aimed at a tonne-scale {sup 76}Ge neutrinoless double-beta decay ({beta}{beta}(0{nu})-decay) experiment. The current, primary focus is the construction of the Majorana Demonstrator experiment, an R and D effort that will field approximately 40 kg of germanium detectors with mixed enrichment levels. This article provides a status update on the construction of the Demonstrator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmic Ray Interactions in Shielding Materials

This document provides a detailed study of materials used to shield against the hadronic particles from cosmic ray showers at Earth’s surface. This work was motivated by the need for a shield that minimizes activation of the enriched germanium during transport for the MAJORANA collaboration. The materials suitable for cosmic-ray shield design are materials such as lead and iron that will stop the primary protons, and materials like polyethylene, borated polyethylene, concrete and water that will stop the induced neutrons. The interaction of the different cosmic-ray components at ground level (protons, neutrons, muons) with their wide energy range (from kilo-electron volts to giga-electron volts) is a complex calculation. Monte Carlo calculations have proven to be a suitable tool for the simulation of nucleon transport, including hadron interactions and radioactive isotope production. The industry standard Monte Carlo simulation tool, Geant4, was used for this study. The result of this study is the assertion that activation at Earth’s surface is a result of the neutronic and protonic components of the cosmic-ray shower. The best material to shield against these cosmic-ray components is iron, which has the best combination of primary shielding and minimal secondary neutron production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design Considerations for Large Mass Ultra-Low Background Experiments

Summary The objective of this document is to present the designers of the next generation of large-mass, ultra-low background experiments with lessons learned and design strategies from previous experimental work. Design issues divided by topic into mechanical, thermal and electrical requirements are addressed. Large mass low-background experiments have been recognized by the scientific community as appropriate tools to aid in the refinement of the standard model. The design of these experiments is very costly and a rigorous engineering review is required for their success. The extreme conditions that the components of the experiment must withstand (heavy shielding, vacuum/pressure and temperature gradients), in combination with unprecedented noise levels, necessitate engineering guidance to support quality construction and safe operating conditions. Physical properties and analytical results of typical construction materials are presented. Design considerations for achieving ultra-low-noise data acquisition systems are addressed. Five large-mass, low-background conceptual designs for the one-tonne scale germanium experiment are proposed and analyzed. The result is a series of recommendations for future experiments engineering and for the Majorana simulation task group to evaluate the different design approaches.

1TGe One-tonne 76Ge neutrinoless double beta-decay↗

Majorana One-Tonne Cryostat Cooling Conceptual Feasibility Study Rev 1

This report evaluates the conceptual plans for a cryostat cooling design for the MAJORANA DEMONSTRATOR (MJD) one-tonne (S4) experiment. This document is based upon previous design work and experimental results used to evaluate the current MJD thermal design. A feasibility study of a cooling system for S4 based on the MJD thermosiphon experiment is presented. The one-tonne experiment will be a scaled up version of the MJD. There will be many cryostats in the S4 experiment. In this document a cryostat with up to 19 strings of germanium crystals is analyzed. Aside from an extra outer ring of crystals, the geometry of the cryostat for S4 is very similar to that for the MJD thermosiphon experiment. The materials used in the fabrication of both of these ultra-low background experiments will be underground-electroformed copper. The current MJD uses a two-phase liquid-gas cooling system to provide constant operating temperature. This document presents a theoretical investigation of a cooling system for the S4 experiment and evaluates the heat transfer performance requirements for such a system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo Simulations of Cosmic Rays Hadronic Interactions

This document describes the construction and results of the MaCoR software tool, developed to model the hadronic interactions of cosmic rays with different geometries of materials. The ubiquity of cosmic radiation in the environment results in the activation of stable isotopes, referred to as cosmogenic activities. The objective is to use this application in conjunction with a model of the MAJORANA DEMONSTRATOR components, from extraction to deployment, to evaluate cosmogenic activation of such components before and after deployment. The cosmic ray showers include several types of particles with a wide range of energy (MeV to GeV). It is infeasible to compute an exact result with a deterministic algorithm for this problem; Monte Carlo simulations are a more suitable approach to model cosmic ray hadronic interactions. In order to validate the results generated by the application, a test comparing experimental muon flux measurements and those predicted by the application is presented. The experimental and simulated results have a deviation of 3%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Noise Performance Evaluation of the Candidate Digitizers for the MAJORANA DEMONSTRATOR

The noise performance evaluation of the two digitizer cards being considered for the MAJORANA DEMONSTRATOR (MJD) is presented in this document. The procurement of the data acquisition electronics for the MJD is scheduled to happen this year. At the time of writing this document, there are two candidate digitizer electronic boards. One aspect that is being considered by the collaboration is the feasibility of using the MJD for dark matter searches. The feasibility of using the MJD for this application is going to be dictated by the ability of the demonstrator to reach sub-keV energy resolution. One of the potential sources of noise in the MJD is the data acquisition system. This document will is concluded with a recommendation for the final digitizer board by comparing the noise performance of the two electronics systems. Noise parameters such as the effective number of bits, input range linearity and signal to noise ratio are experimentally determined. The two digitizer cards feature different on-board digital signal processing and these features are compared. The experimental set-up was also used to identify sources of noise. This paper describes these sources of noise in the data acquisition system, along with mitigation strategies. Issues such as grounding and wiring scheme have an impact in the overall data acquisition system performance and are discussed in detail. As a conclusion, the suitability of each one of the cards to become the back bone of the data acquisition system of the MJD is discussed.

99 GENERAL AND MISCELLANEOUS↗

Majorana One-Tonne Cryostat Cooling Conceptual Feasibility Study

This report evaluates the conceptual plans for a one-tonne (S4) cryostat cooling design. This document is based upon previous design work and experimental results used to evaluate the current MAJORANA DEMONSTRATOR (MJD) thermal design. A feasibility study of a cooling system for S4 based on the MJD thermosyphon experiment is presented. The one-tonne experiment will be a scaled up version of the MJD. There will be many cryostats for the S4 experiment. In this document a cryostat with up to 19 strings of Germanium crystals is analyzed. Aside from an extra outer ring of crystals, the geometry of both systems’ cryostats is very similar. The materials used in the fabrication of both ultra-low background experiments will be underground electroformed copper. The current MJD uses a two-phase liquid-gas cooling system to ensure constant operating temperature. This document presents a theoretical investigation of a cooling system for the S4 experiment and evaluates the heat transfer performance requirements for such a system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a Portable Muon Witness System

Since understanding and quantifying cosmic ray induced radioactive backgrounds in copper and germanium are important to the MAJORANA DEMONSTRATOR, methods are needed for monitoring the levels of such backgrounds produced in materials being transported and processed for the experiment. This report focuses on work conducted at Pacific Northwest National Laboratory to develop a muon witness system as a one way of monitoring induced activities. The operational goal of this apparatus is to characterize cosmic ray exposure of materials. The cosmic ray flux at the Earth’s surface is composed of several types of particles, including neutrons, muons, gamma rays and protons. These particles induce nuclear reactions, generating isotopes that contribute to the radiological background. Underground, the main mechanism of activation is by muon produced spallation neutrons since the hadron component of cosmic rays is removed at depths greater than a few tens of meters. This is a sub-dominant contributor above ground, but muons become predominant in underground experiments. For low-background experiments cosmogenic production of certain isotopes, such as 68Ge and 60Co, must be accounted for in the background budgets. Muons act as minimum ionizing particles, depositing a fixed amount of energy per unit length in a material, and have a very high penetrating power. Using muon flux measurements as a “witness” for the hadron flux, the cosmogenic induced activity can be quantified by correlating the measured muon flux and known hadronic production rates. A publicly available coincident muon cosmic ray detector design, the Berkeley Lab Cosmic Ray Detector (BLCRD), assembled by Juniata College, is evaluated in this work. The performance of the prototype is characterized by assessing its muon flux measurements. This evaluation is done by comparing data taken in identical scenarios with other cosmic ray telescopes. The prototype is made of two plastic scintillator paddles with associated electronics to measure energy depositions in coincidence in the two paddles. For this particular application of the prototype, the measurements performed concentrated on a broad investigation of the dependence of the muon flux on depth underground. These tests were conducted inside at Building 3420/1307 and underground at Building 3425 at the Pacific Northwest National Laboratory. The second half of this report analyzes modifications to the electronics of the BLCRD to make this detector portable. Among other modifications, a battery powered version of these electronics is proposed for the final Muon Witness design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Majorana Thermosyphon Prototype Experimental Results

Objective The Majorana demonstrator will operate at liquid Nitrogen temperatures to ensure optimal spectrometric performance of its High Purity Germanium (HPGe) detector modules. In order to transfer the heat load of the detector module, the Majorana demonstrator requires a cooling system that will maintain a stable liquid nitrogen temperature. This cooling system is required to transport the heat from the detector chamber outside the shield. One approach is to use the two phase liquid-gas equilibrium to ensure constant temperature. This cooling technique is used in a thermosyphon. The thermosyphon can be designed so the vaporization/condensing process transfers heat through the shield while maintaining a stable operating temperature. A prototype of such system has been built at PNNL. This document presents the experimental results of the prototype and evaluates the heat transfer performance of the system. The cool down time, temperature gradient in the thermosyphon, and heat transfer analysis are studied in this document with different heat load applied to the prototype.