Search NASA⌕ Search

Engineering topics

Agustsson, R.

Publications and source records attributed to Agustsson, R..

33 records · Page 2

Thermionic microwave gun for terahertz and synchrotron light sources

Conventional thermionic microwave and radiofrequency (RF) guns can offer high average beam current, which is important for synchrotron light and terahertz (THz) radiation source facilities, as well as for industrial applications. For example, the Advanced Photon Source at Argonne National Laboratory is a national synchrotron radiation light source research facility that utilizes thermionic RF guns. Yet, these existing thermionic guns are bulky, difficult to handle and install, easily detuned, very sensitive to thermal expansion, and are due for a major upgrade and replacement. Here, we present the design of a new, more stable and reliable gun with optimized electromagnetic performance, improved thermal engineering and a more robust cathode mounting technique, which is a critical step to improve the performance of existing and future light sources, industrial accelerators, and electron beam-driven terahertz sources. We will also present a fabricated gun prototype and show results of high-power and beam tests.

47 OTHER INSTRUMENTATION↗

Observation of a THz-sub-THz spontaneous coherent undulator radiation driven by a low energy electron beam from a thermionic RF electron gun

In this work, we report observations of an intense, multi-band, sub-THz and THz radiation extracted from a similar to 2-3 MeV electron beam with a flat transverse profile propagating in an oversized rectangular waveguide placed into a 3.25 mm gap of a planar undulator having 1.3 cm period and similar to 20 cm length. Radiation outcoupling is accomplished using a horn antenna and a miniature permanent in-vacuum magnet separating the mm-sub-mm-waves and electron beam. A table-top experiment utilizes a radio frequency thermionic electron gun delivering a thousand momentum-chirped microbunches per macropulse and an alpha-magnet producing microbunches of a sub-mm length. Total radiated energy of a sub-millijoule per a microsecond radio frequency macropulse is demonstrated with flux more than ten micro-Joules per centimeter squared. With 1 THz filter the energy measured is about 1 microjoule and flux of a few micro-Joules per centimeter squared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Four-harmonic buncher for radioactive and stable beams switching at the ATLAS facility [Four-harmonic buncher for radioactive and stable beams combination at the ATLAS facility]

Here, the Argonne Tandem Linac Accelerator System (ATLAS) is planning an upgrade to a multi-user facility to simultaneously accelerate both stable beams from an ECR ion source and radioactive beams from an Electron Beam Ion Source charge breeder. The ATLAS Multi-User Upgrade will need to provide high transmission of ion beams with a mass-to-charge ratio up to 7 as it enables more options to alternate radioactive and stable beams. Currently, the bunching is provided with a lumped circuit multi-harmonic buncher, which cannot effectively operate at the required amplitude of the saw-tooth voltage for ions with mass-to-charge ratio of 7 due to thermal issues. RadiaBeam Systems in collaboration with Argonne National Laboratory has designed a four-harmonic coaxial resonator buncher with the ATLAS fundamental frequency of 12.125 MHz, and a compact, less than 2-m-long, footprint, capable of providing the required voltage of 6.2 kV. This device allows fast and reliable pre-bunching of DC ion beams with the capability of fast switching of heavy-ion radioactive and stable beams for delivery to multiple users. In this paper, we will discuss the RF and engineering design considerations of this buncher.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A NEW THERMIONIC RF ELECTRON GUN FOR SYNCHROTRON LIGHT SOURCES

A thermionic RF gun is a compact and efficient source of electrons used in many practical applications. RadiaBeam Systems and the Advanced Photon Source at Argonne National Laboratory collaborate in developing of a reliable and robust thermionic RF gun for synchrotron light sources which would offer substantial improvements over existing thermionic RF guns and allow stable operation with up to 1A of beam peak current at a 100 Hz pulse repetition rate and a 1.5 μs RF pulse length. In this paper, we discuss the electromagnetic and engineering design of the cavity and report the progress towards high power tests of the cathode assembly of the new gun.

RF↗

THz and Sub-THz Capabilities of a Table-Top Radiation Source Driven by an RF Thermionic Electron Gun

Design features and experimental results are presented for a sub-mm wave source [1] based on APS RF thermionic electron gun. The setup includes compact alpha-magnet, quadrupoles, sub-mm-wave radiators, and THz optics. The sub-THz radiator is a planar, oversized structure with gratings. Source upgrade for generation frequencies above 1 THz is discussed. The THz radiator will use a short-period undulator having 1 T field amplitude, ~20 cm length, and integrated with a low-loss oversized waveguide. Both radiators are integrated with a miniature horn antenna and a small ~90°-degree in-vacuum bending magnet. The electron beamline is designed to operate different modes including conversion to a flat beam interacting efficiently with the radiator. The source can be used for cancer diagnostics, surface defectoscopy, and non-destructive testing. Sub-THz experiment demonstrated a good potential of a robust, table-top system for generation of a narrow bandwidth THz radiation. This setup can be considered as a prototype of a compact, laser-free, flexible source capable of generation of long trains of Sub-THz and THz pulses with repetition rates not available with laser-driven sources.

Smirnov, Alexei V.↗

High duty cycle inverse Compton scattering X-ray source

Inverse Compton Scattering (ICS) is an emerging compact X-ray source technology, where the small source size and high spectral brightness are of interest for multitude of applications. However, to satisfy the practical flux requirements, a high-repetition-rate ICS system needs to be developed. To this end, this article reports the experimental demonstration of a high peak brightness ICS source operating in a burst mode at 40 MHz. A pulse train interaction has been achieved by recirculating a picosecond CO 2 laser pulse inside an active optical cavity synchronized to the electron beam. The pulse train ICS performance has been characterized at 5- and 15- pulses per train and compared to a single pulse operation under the same operating conditions. Lastly, with the observed near-linear X-ray photon yield gain due to recirculation, as well as noticeably higher operational reliability, the burst-mode ICS offers a great potential for practical scalability towards high duty cycles.

43 PARTICLE ACCELERATORS↗

High Gradient Accelerating Structures for Carbon Therapy Linac

Carbon therapy is the most promising among techniques for cancer treatment, as it has demonstrated significant improvements in clinical efficiency and reduced toxicity profiles in multiple types of cancer through much better localization of dose to the tumor volume. RadiaBeam, in collaboration with Argonne National Laboratory, are developing an ultra-high gradient linear accelerator, Advanced Compact Carbon Ion Linac (ACCIL), for the delivery of ion-beams with end-energies up to 450 MeV/u for 12C6+ ions and 250 MeV for protons. In this paper, we present a thorough comparison of standing and travelling wave designs for high gradient S-Band accelerating structures operating with ions at varying velocities, relative to the speed of light, in the range 0.3-0.7. In this paper we will compare these types of accelerating structures in terms of RF, beam dynamics and thermo-mechanical performance.

Kutsaev, Sergey↗

Measuring single-shot, picosecond optical damage threshold in Ge, Si, and sapphire with a 5.1-μm laser

Optical photonic structures driven by picosecond, GW-class lasers are emerging as promising novel sources of electron beams and high quality X-rays. Due to quadratic dependence on wavelength of the laser ponderomotive potential, the performance of such sources scales very favorably towards longer drive laser wavelengths. However, to take full advantage of photonic structures at mid-IR spectral region, it is important to determine optical breakdown limits of common optical materials. To this end, an experimental study was carried out at a wavelength of 5 µm, using a frequency-doubled CO 2 laser source, with 5 ps pulse length. Single-shot optical breakdowns were detected and characterized at different laser intensities, and damage threshold values of 0.2, 0.3, and 7.0 J/cm 2 , were established for Ge, Si, and sapphire, respectively. As a result, the measured damage threshold values were stable and repeatable within individual data sets, and across varying experimental conditions.

43 PARTICLE ACCELERATORS↗

Laser-free RF-gun as a combined source of THz and ps-sub-ps X-rays

A coherent, mm-sub-mm-wave source driven by a RF electron gun is proposed for wide research applications as well as auxiliary inspection and screening, safe imaging, cancer diagnostics, surface defectoscopy, and enhanced time-domain spectroscopy. It allows generation of high peak and average THz-sub-THz radiation power provided by beam pre-bunching and chirping in the RF gun followed by microbunching in magnetic compressor, and resonant Cherenkov radiation of an essentially flat beam in a robust, ~inch-long, planar, mm-sub-mm gap structure. The proof-of-principle has been successfully demonstrated in Phase I on a 5 MeV beam of L-band thermionic injector of Idaho Accelerator Center. The system can also deliver an intense, ps-sub-ps bursts of low-to-moderate dose of relativistic electrons and X-ray radiation produced by the same beam required for pulsed radiolysis as well as to enhance screening efficiency, throughput and safety.

43 PARTICLE ACCELERATORS↗