Shot 3 Post-Shot Report: Fault Analysis of MK-X Data [Slides]

This presentation constitutes a post-shot report for the MK-X performance on Shot 3 (13 July 2022). It focuses primarily on the analysis of electrical faults which have been a persistent issue in MK-X performance and were a significant focus of the test. The MK-X is a helical flux compression generator (HFCG) that has been manufactured in a novel and very cost-effective way. Shot 3 was the fourth test in a series which began with a low initial-current-level HFCG test coupled to a dummy load (Shot 0) and then a high stress test (Shot 1) coupled to a primitive pulse forming network (PFN). Shot 0 performed close to expectation but Shot 1 had early time losses that could not be explained. As a result, Shots 2 and 3 had dual goals. Each shot looked at MK-X performance relative to the early time losses, and since the amount of current generated on the first two tests was a useful amount, we coupled to a fast R43S Ranchero flux compression generator for Shot 2 to ascertain Ranchero’s performance with higher-than-ever initial current and another PFN load. Then Shot 3 implemented a specific change to the MK-X and coupled to only a low inductance PFN load. The report shows that Shots 1-3 all have qualitatively similar losses and the change made for Shot 3 to explore losses led to even further losses. However, the PFN on shot 3 was low inductance and in spite of the losses, 32 MA was generated. This report discusses the losses seen specifically on Shot 3 and compares the electrical and camera data along with a careful comparison to 3 D MHD modeling.

42 ENGINEERING↗

Tank Side Cesium Removal IXC-150 Cask Detonation Report

A set of experiments were conducted at Los Alamos National Laboratory’s firing point 88 to determine the blast pressure and effects of a stoichiometric gas mixture of Hydrogen (H 2 ) and Nitrous Oxide (N 2 O) on the IXC-150 Storage Pad Vent Stack assemblies. The Lab was asked to design, build, and test the vent stack assemblies using a reaction gas volume of 340 in 3 that mimics the Tank Side Cesium Removal (TSCR) Ion Exchange Column (IXC) assembly. The experimental system with vent stack assembly was designed with input from the Washington River Protection Services (WRPS) to ensure an accurate test setup. The tests were conducted at LANL on the newly built filter/gas assembly at the end of April 2021 timeframe, using WRPS supplied vent stack assemblies and internal HEPA filters. The objective of these tests was to observe that the structural integrity of the vent stack assemblies was maintained and determine the resulting blast overpressures at a distance of 16 and 32 inches from the assembly. All work was performed under the LANL Quality Assurance Program (SD330), using a graded application of ASME NQA-1- 2008/NQA-1a-2009. To ensure that all client quality assurance (QA) expectations were addressed, evaluation of the end data needs was performed and the appropriate controls applied for this work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗