Search NASA⌕ Search

Engineering topics

Ahmed, Irfan

Publications and source records attributed to Ahmed, Irfan.

Beyond Binary: Automated PLC Memory Forensics through RGB Image Analysis and Deep Learning

The introduction of Industry 4.0 and the evolution of industrial control systems (ICS) to adopt Internet-based technologies enhanced productivity, but have inadvertently increased their vulnerability to cyber-based malicious attacks. When an ICS system is compromised, security analysts need to identify the root cause quickly to start the recovery process and develop mitigation strategies to safeguard against future instances. Memory forensics is critical in the analysis process to ascertain what occurred. To date, approaches to analyze the persistent memory in ICS devices are limited, and almost nonexistent for volatile memory. This paper proposes an automated methodology, COMA, for PLC memory dump analysis using computer vision and deep learning techniques. Specifically, COMA converts the sequences of bytes in a PLC memory dump to RGB pixels and creates a deep learning model that learns the underlying patterns and features of pre-labeled forensic artifacts in images and segments them into distinct regions. COMA then uses the trained model to automatically segment new memory images and extract forensic artifacts. We evaluate COMA on a Schneider Electric Modicon M221 PLC involving two cyber-based attack scenarios: (i) code injection and (ii) code modification. The empirical results show that COMA can successfully detect attack artifacts in memory dumps in both scenarios.

Asmar Awad, Rima↗

Memory forensic analysis of a programmable logic controller in industrial control systems

In industrial control systems (ICS), programmable logic controllers (PLCs) are used to automate physical processes such as nuclear plants and power grid stations, and are often subject to cyber attacks. As in conventional IT domain, the memory analysis of the PLCs can help answer important forensic questions about the attack, such as the presence of malicious firmware, injection of modified control logic (the program running on the PLC), and manipulation of I/O devices (e.g., sensors and actuators). Unlike conventional IT domain, PLCs have heterogeneous hardware architecture, proprietary firmware and control software, making it challenging to employ a unified framework for their memory forensics. For merely extracting artifacts of forensic importance, reverse-engineering the firmware is a tedious task, and the effort needs to be repeated for every PLC model. As a community, a step-wise approach to tackle this challenge is to analyze the memory of specific PLCs, and subsequently find a generic framework applicable to all PLCs. Our work is a step forward in this direction. By following a methodology that focuses on the functional layer of PLCs instead of reverse engineering the firmware, we analyze the digital forensic artifacts available in a common PLC, Allen-Bradley ControlLogix 1756-L61. Before diving into the memory dump, we analyze the PLC control software to create a list of important artifacts that are sure to exist in the PLC memory dump. The approach employs a setup where PLC control software RSLogix-5000 is connected to the PLC, and the memory dump can be obtained as and when needed. We create test cases that sequentially highlight each category of artifacts, followed by an examination of the resultant impact on memory. After attaining the listed artifacts, we employ conventional string and known data searches to extract interesting information present in this PLC's memory. The memory analysis profile, presented as a Python library and shared with the community, can help a forensic investigator to readily extract forensic artifacts from the same model's controller. The adopted approach may help researchers in creating memory profile of other PLCs, and ultimately formulating a generic PLC memory analysis framework.

Rais, Muhammad Haris↗

JTAG-based PLC memory acquisition framework for industrial control systems

In industrial control systems (ICS), programmable logic controllers (PLC) are the embedded devices that directly control and monitor critical industrial infrastructure processes such as nuclear plants and power grid stations. Cyberattacks often target PLCs to sabotage a physical process. A memory forensic analysis of a suspect PLC can answer questions about an attack, including compromised firmware and manipulation of PLC control logic code and I/O devices. Given physical access to a PLC, collecting forensic information from the PLC memory at the hardware-level is risky and challenging. It may cause the PLC to crash or hang since PLCs have proprietary, legacy hardware with heterogeneous architecture. This paper addresses this research problem and proposes a novel JTAG (Joint Test Action Group)-based framework, Kyros, for reliable PLC memory acquisition. Kyros systematically creates a JTAG profile of a PLC through hardware assessment, JTAG pins identification, memory map creation, and optimizing acquisition parameters. It also facilitates the community of interest (such as ICS owners, operators, and vendors) to develop the JTAG profiles of PLCs. Further, we present a case study of Kyros implementation over Allen-Bradley 1756-A10/B to help understand the framework's application on a real-world PLC used in industry settings. The sample PLC memory dumps are shared with the research community to facilitate further research.

Rais, Muhammad Haris↗

Attacking the IEC-61131 Logic Engine in Programmable Logic Controllers in Industrial Control Systems

In industrial control systems (ICS), programmable logic controllers (PLCs) directly monitor and control a physical process such as nuclear power plants, gas pipelines, and water treatment. They are equipped with a control logic written in IEC-61131 languages (e.g., ladder logic and structured text) that defines how a PLC should control a physical process. A PLC's control logic is a usual target of a cyberattack to sabotage a physical process. For instance, Stuxnet targets a control logic of a Siemens S7-300 PLC to damage a nuclear facility's centrifuges. The existing attacks in the literature generally focus only on injecting malicious control logic into a PLC. This paper presents a new dimension of control logic attacks that target the control logic engine (responsible for running a control logic) of a PLC. It demonstrates that a cyberattack can disable the control logic engine successfully by exploiting inherent PLC features such as program mode and starting/stopping engine. We develop two novel case studies on control logic engine attacks by employing the MITRE ATT\&CK knowledge base on the real-world PLCs used in industry settings, i.e., 1) Schweitzer Engineering Laboratory (SEL)'s Real-Time Automation Controller (SEL-3505 RTAC) equipped with security features such as encrypted traffic and device-level access control, and 2) traditional PLCs, i.e., Schneider Electric's Modicon M221, Allen-Bradley's MicroLogix 1400 and 1100 that do not have security features. The case studies present the internals of the logic engine attacks and facilitate the ICS research community and industry to understand the attack vectors on the control logic engine. We evaluate the effectiveness of the control engine attacks on a power substation, a 4-floor elevator, and a conveyor belt to demonstrate their real-world impact of halting a physical process.

Ali qasim, Syed↗

Automated Reconstruction of Control Logic for Programmable Logic Controller Forensics

This paper presents Similo, an automated scalable framework for control logic forensics in industrial control systems. Similo is designed to investigate denial of engineering operations (DEO) attacks, recently demonstrated to hide malicious control logic in a programmable logic controller (PLC) at field sites from an engineering software (at control center). The network traffic (if captured) contains substantial evidence to investigate DEO attacks including manipulation of control logic. Laddis, a state-of-the-art forensic approach for DEO attacks, is a binary-logic decompiler for the Allen-Bradley’s RSLogix engineering software and MicroLogix 1400 PLC. It is developed with extensive manual reverse engineering effort of the underlying proprietary network protocol and the binary control logic. Unfortunately, Laddis is not scalable and requires similar efforts to extend on other engineering software/PLCs. The proposed solution, Similo, is based on the observation that engineering software of different vendors are equipped with decompilers. Similo is a virtual-PLC framework that integrates the decompilers with their respective (previously-captured) ICS network traffic of control logic. It recovers the binary logic into a high-level source code (of the programming languages defined by IEC 61131-3 standard) automatically. Similo can work with both proprietary/open protocols without requiring protocol specifications and the binary formats of control logic. Thus, it is scalable to different ICS vendors. We evaluate Similo on three PLCs of two ICS vendors, i.e. MicroLogix 1400, MicroLogix 1100, and Modicon M221. These PLCs support proprietary protocols and the control logics written in two programming languages: Ladder Logic and Instruction List. The evaluation results show that Similo can accurately reconstruct a control logic from an ICS network traffic and can be used to investigate the DEO attacks effectively.

Ali qasim, Syed↗

Overshadow PLC to Detect Remote Control-Logic Injection Attacks

Programmable logic controllers (PLCs) in industrial control systems (ICS) are vulnerable to remote control logic injection attacks. Attackers target the control logic of a PLC to manipulate the behavior of a physical process such as nuclear plants, power grids, and gas pipelines. Control logic attacks have been studied extensively in the literature, including hiding the transfer of a control logic over the network from both packet header-based signatures, and deep packet inspection. For instance, these attacks transfer a control logic code as data, into small fragments (one-byte per packet), that are further padded with noise data. To detect control logic in ICS network traffic, this paper presents Shade, a novel shadow memory technique that observes the network traffic to maintain a local copy of the current state of a PLC memory. To analyze the memory contents, Shade employs a classification algorithm with 42 unique features categorized into five types at different semantic levels of a control logic code, such as number of rungs, number of consecutive decompiled instructions, and n-grams. We then evaluate Shade against control logic injection attacks on two PLCs, Modicon M221 and MicroLogix 1400 from two ICS vendors, Schneider electric and Allen-Bradley, respectively. The evaluation results show that Shade can detect an attack instance (i.e., identifying at least one attack packet during the transfer of a malicious control logic) accurately without any false alarms.

Yoo, Hyunguk↗

Use of a New Hybrid Heparin-Bonded Nitinol Ring Stent in the Popliteal Artery: Procedural and Mid-term Clinical and Anatomical Outcomes

PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVR > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Charge transport through split photoelectrodes in dye-sensitized solar cells

Charge transport and recombination are relatively ignored parameters while upscaling dye-sensitized solar cells (DSCs). Enhanced photovoltaic parameters are anticipated by merely widening the devices physical dimensions, viz., thickness and area as evident from the device design adopted in reported large area DSCs. These strip designs lead to ≤50% loss in photocurrent compared to the high efficiency lab scale devices. Herein, we report that the key to achieving higher current density (J{sub SC}) is optimized diffusion volume rather than the increased photoelectrode area because kinetics of the devices is strongly influenced by the varied choices of diffusion pathways upon increasing the electrode area. For a given electrode area and thickness, we altered the photoelectrode design by splitting the electrode into multiple fractions to restrict the electron diffusion pathways. We observed a correlation between the device physical dimensions and its charge collection efficiency via current-voltage and impedance spectroscopy measurements. The modified electrode designs showed >50% increased J{sub SC} due to shorter transport time, higher recombination resistance and enhanced charge collection efficiency compared to the conventional ones despite their similar active volume (∼3.36 × 10{sup −4} cm{sup 3}). A detailed charge transport characteristic of the split devices and their comparison with single electrode configuration is described in this article.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Channeling of electron transport to improve collection efficiency in mesoporous titanium dioxide dye sensitized solar cell stacks

Dye-sensitized solar cell (DSC) modules are generally made by interconnecting large photoelectrode strips with optimized thickness (∼14 μm) and show lower current density (J{sub SC}) compared with their single cells. We found out that the key to achieving higher J{sub SC} in large area devices is optimized photoelectrode volume (V{sub D}), viz., thickness and area which facilitate the electron channeling towards working electrode. By imposing constraints on electronic path in a DSC stack, we achieved >50% increased J{sub SC} and ∼60% increment in photoelectric conversion efficiency in photoelectrodes of similar V{sub D} (∼3.36 × 10{sup −4} cm{sup 3}) without using any metallic grid or a special interconnections.

30 DIRECT ENERGY CONVERSION↗

The Use of Biodegradable Stents in Malignant Oesophageal Strictures for the Treatment of Dysphagia Before Neoadjuvant Treatment or Radical Radiotherapy: A Feasibility Study

PurposeTo evaluate the clinical results of the use of biodegradable oesophageal stents in malignant strictures.MethodsEleven patients were included in this prospective analysis in which a woven polydioxanone biodegradable oesophageal stent was used. The inclusion criterion was that the patient underwent neoadjuvant treatment or radical radiotherapy after the stent insertion. Primary end points were dysphagia score at discharge, stent patency, and complication rate. Secondary end points were overall survival and surgical outcome of surgery.ResultsThere was a 100 % procedure technical success rate. Early complications occurred in three patients resulting in failure to restore oral nutrition. In the remaining eight patients, dysphagia was significantly improved at discharge. Mean stent patency rate in this group was 71.5 days. Stent dysfunction occurred in five of eight patients (62.5 %); in two of five patients this was due to local inflammatory reaction, and in three of five patients it was due to tumour growth after a mean time of 97.8 days, and a new metallic stent was consequently placed in four of five patients. One patient was successfully treated with esophagectomy. At the end of follow-up (mean time 102.1 days), three of eight stents were patent. The overall patient survival rate was 81.8 %.ConclusionAlthough short-term dysphagia scores improved, biodegradable stents do not appear to offer a clear beneficial effect in most cases of malignant strictures, particularly due to a local inflammatory reaction that may be induced. Technical improvement of the device and delineation of the patient group that would benefit from its use is necessary if further studies are to be conducted in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Incidental Radiation Dose to Uninvolved Mediastinal/Supraclavicular Lymph Nodes in Patients with Limited-Stage Small Cell Lung Cancer Treated Without Elective Nodal Irradiation

Classic teaching states that treatment of limited-stage small cell lung cancer (L-SCLC) requires large treatment fields covering the entire mediastinum. However, a trend in modern thoracic radiotherapy is toward more conformal fields, employing positron emission tomography/computed tomography (PET/CT) scans to determine the gross tumor volume (GTV). This analysis evaluates the dosimetric results when using selective nodal irradiation (SNI) to treat a patient with L-SCLC, quantitatively comparing the results to standard Intergroup treatment fields. Sixteen consecutive patients with L-SCLC and central mediastinal disease who also underwent pretherapy PET/CT scans were studied in this analysis. For each patient, we created SNI treatment volumes, based on the PET/CT-based criteria for malignancy. We also created 2 ENI plans, the first without heterogeneity corrections, as per the Intergroup 0096 study (ENI{sub off}) and the second with heterogeneity corrections while maintaining constant the number of MUs delivered between these latter 2 plans (ENI{sub on}). Nodal stations were contoured using published guidelines, then placed into 4 'bins' (treated nodes, 1 echelon away, >1 echelon away within the mediastinum, contralateral hilar/supraclavicular). These were aggregated across the patients in the study. Dose to these nodal bins and to tumor/normal structures were compared among these plans using pairwise t-tests. The ENI{sub on} plans demonstrated a statistically significant degradation in dose coverage compared with the ENI{sub off} plans. ENI and SNI both created a dose gradient to the lymph nodes across the mediastinum. Overall, the gradient was larger for the SNI plans, although the maximum dose to the '1 echelon away' nodes was not statistically different. Coverage of the GTV and planning target volume (PTV) were improved with SNI, while simultaneously reducing esophageal and spinal cord dose though at the expense of modestly reduced dose to anatomically distant lymph nodes within the mediastinum. The ENI{sub on} plans demonstrate that intergroup-style treatments, as actually delivered, had statistically reduced coverage to the mediastinum and tumor volumes than was reported. Furthermore, SNI leads to improved tumor coverage and reduced esophageal/spinal cord dose, which suggests the possibility of dose escalation using SNI.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multiple Intrahepatic Artery Aneurysms in a Patient with Behcet's Disease: Use of Transcatheter Embolization for Rupture

Intrahepatic artery aneuryms are a rare and potentially life-threatening condition. We present the first case in the English literature of multiple intrahepatic artery aneuryms in a patient with Behcet's disease who presented acutely with rupture. The ruptured aneurysm was treated successfully with transcatheter arterial coil embolization-CT and clinical follow-up confirming a good result. We discuss the management dilemma with regard to prophylactic embolization of the numerous other small asymptomatic intrahepatic aneurysms in this same patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of a Brachiocephalic Artery Pseudoaneurysm Secondary to Biopsy at Mediastinoscopy

Isolated injury to the brachiocephalic artery is relatively rare. We report the case of a 53-year-old lymphoma patient who had had a biopsy at mediastinoscopy in the past and was found incidentally on routine staging computed tomography to have developed a large pseudoaneurysm of the brachiocephalic artery. We describe the successful percutaneous treatment of this iatrogenic injury using endovascular deployment of covered stent-grafts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗