Search NASA⌕ Search

Engineering topics

Ahmed, S.

Publications and source records attributed to Ahmed, S..

At least 19 records

Calibration and Measurement techniques in the LLRF systems of the Fermilab PIP-II Linac

he PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems are a based on two different hardware platforms controlling a variety of cavity types and resonance control systems including temperature, pneumatic and piezzo tuners. The various calibrations required prior to beam operation include, signal power, gradient, amplifier characterization, cavity Q measurement and detune constants. Measurements such as piezzo capacitance, cavity piezo transfer function help in determining tuner health and in devising microphonics control strategies. These measurement and calibration methods of the PIP-II LLRF system are discussed here.

Varghese, P.↗

DIII-D research to provide solutions for ITER and fusion energy

The DIII-D tokamak has elucidated crucial physics and developed projectable solutions for ITER and fusion power plants in the key areas of core performance, boundary heat and particle transport, and integrated scenario operation, with closing the core-edge integration knowledge gap being the overarching mission. New experimental validation of high-fidelity, multi-channel, non-linear gyrokinetic turbulent transport models for ITER provides strong confidence it will achieve Q ≥ 10 operation. Experiments identify options for easing H-mode access in hydrogen, and give new insight into the isotopic dependence of transport and confinement. Analysis of 2,1 islands in unoptimized low-torque IBS demonstration discharges suggests their onset time occurs randomly in the constant β phase, most often triggered by non-linear 3-wave coupling, thus identifying an NTM seeding mechanism to avoid. Pure deuterium SPI for disruption mitigation is shown to provide favorable slow cooling, but poor core assimilation, suggesting paths for improved SPI on ITER. At the boundary, measured neutral density and ionization source fluxes are strongly poloidally asymmetric, implying a 2D treatment is needed to model pedestal fuelling. Detailed measurements of pedestal and SOL quantities and impurity charge state radiation in detached divertors has validated edge fluid modelling and new self-consistent 'pedestal-to-divertor' integrated modeling that can be used to optimize reactors. New feedback adaptive ELM control minimizes confinement reduction, and RMP ELM suppression with sustained high core performance was obtained for the first time with the outer strike point in a W-coated, compact and unpumped small-angle slot divertor. Advances have been made in integrated operational scenarios for ITER and power plants. Wide pedestal intrinsically ELM-free QH-modes are produced with more reactor-relevant conditions, Low torque IBS with W-equivalent radiators can exhibit predator-prey oscillations in Te and radiation which need control. High-β P scenarios with q min > 2, q 95 –7.9, β N > 4, β T –3.3% and H 98y2 > 1.5 are sustained with high density ($\overline{n}$ = 7E19 m -3 , f G –1) for 6 τ E , improving confidence in steady-state tokamak reactors. Diverted NT plasmas achieve high core performance with a non-ELMing edge, offering a possible highly attractive core-edge integration solution for reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Continuous Electron Beam Accelerator Facility at 12 GeV

This review paper describes the energy-upgraded Continuous Electron Beam Accelerator Facility (CEBAF) accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing 88 superconducting cavities that have operated cw at an average accelerating gradient of 20 MV / m . After reviewing the attributes and performance of the previous 6 GeV CEBAF accelerator, we discuss the upgraded CEBAF accelerator system in detail with particular attention paid to the new beam acceleration systems. In addition to doubling the acceleration in each linac, the upgrade included improving the beam recirculation magnets, adding more helium cooling capacity to allow the newly installed modules to run cold, adding a new experimental hall, and improving numerous other accelerator components. We review several of the techniques deployed to operate and analyze the accelerator performance and document system operating experience and performance. In the final portion of the document, we present much of the current planning regarding projects to improve accelerator performance and enhance operating margins, and our plans for ensuring CEBAF operates reliably into the future. For the benefit of potential users of CEBAF, the performance and quality measures for the beam delivered to each of the experimental halls are summarized in the Appendix. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Observation of J / ψ decays to e + e − e + e − and e + e − μ + μ −

Using a data sample of 4.481 × 10 8 ψ ( 3686 ) events collected with the BESIII detector, we report the first observation of the four-lepton-decays J / ψ → e + e − e + e − and J / ψ → e + e − μ + μ − utilizing the process ψ ( 3686 ) → π + π − J / ψ . The branching fractions are determined to be [ 5.48 ± 0.31 ( stat ) ± 0.45 ( syst ) ] × 10 − 5 and [ 3.53 ± 0.22 ( stat ) ± 0.13 ( syst ) ] × 10 − 5 , respectively. The results are consistent with theoretical predictions. No significant signal is observed for J / ψ → μ + μ − μ + μ − , and an upper limit on the branching fraction is set at 1.6 × 10 − 6 at the 90% confidence level. A C P asymmetry observable is constructed for the first two channels, which is measured to be ( − 0.012 ± 0.054 ± 0.010 ) and ( 0.062 ± 0.059 ± 0.006 ) , respectively. No evidence for C P violation is observed in this process. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

LLRF System for the Fermilab PIP-II Superconducting LINAC

PIP-II is an 800 MEV superconducting linac that is in the initial acceleration chain for the Fermilab accelerator complex. The RF system consists of a warm front-end with an ion source, RFQ and buncher cavities along with 25 superconducting cryo-modules comprised of five different acceleration \(\beta\). The LLRF system for the LINAC has to provide field and resonance control for a total of 125 RF cavities.The LLRF system design is in the final design review phase and will enter the production phase next year. The PIP-II project is an international collaboration with various partner labs contributing subsystems. The LLRF system design for the PIP-II Linac is presented and the specification requirements and system performance in various stages of testing are described in this paper.

43 PARTICLE ACCELERATORS↗

Closed Loop Testing of Microphonics Algorithms Using a Cavity Emulator

An analog crystal filter based cavity emulator is modified with reverse biased varactor diodes to provide a tuning range of around 160 Hz. The piezo drive voltage of the resonance controller is used to detune the cavity through the bias voltage. A signal conditioning and summing circuit allows the introduction of microphonics disturbance from a signal source or using real microphonics data from cavity testing. This setup is used in closed loop with a cavity controller and resonance controller to study the effectiveness of resonance control algorithms suitable for superconducting cavities.

43 PARTICLE ACCELERATORS↗

Measurement of e + e − → ωπ+π− cross section at $\sqrt{s}$ = 2.000 to 3.080 GeV

A partial wave analysis on the process e⁺e⁻ → ωπ⁺π⁻ is performed using 647 pb -1 of data sample collected by using the BESIII detector operating at the BEPCII storage ring at center-of-mass (c.m.) energies from 2.000 GeV to 3.080 GeV. The Born cross section of the e⁺e⁻ → ωπ⁺π⁻ process is measured, with precision improved by a factor of 3 compared to that of previous studies. A structure near 2.25 GeV is observed in the energy-dependent cross sections of e⁺e⁻ → ωπ⁺π⁻ and ωπ 0 π 0 with a statistical significance of 7.6σ, and its determined mass and width are 2232 ± 19 ± 27 MeV/c 2 and 93 ± 53 ± 20 MeV, respectively, where the first and second uncertainties are statistical and systematic, respectively. By analyzing the cross sections of subprocesses e⁺e⁻ → ωf 0 (500), ωf 0 (980), ωf 0 (1370), ωf 2 (1270), and b1(1235)π, a structure, with mass M = 2200 ± 11 ± 17 MeV/c 2 and width Γ = 74 ± 20 ± 24 MeV, is observed with a combined statistical significance of 7.9σ. The measured resonance parameters will help to reveal the nature of vector states around 2.25 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of integrated luminosities at BESIII for data samples at center-of-mass energies between 4.0 and 4.6 GeV*

Abstract The integrated luminosities of data samples collected in the BESIII experiment in 2016–2017 at center-of-mass energies between 4.19 and 4.28 GeV are measured with a precision better than 1% by analyzing large-angle Bhabha scattering events. The integrated luminosities of old datasets collected in 2010–2014 are updated by considering corrections related to detector performance, offsetting the effect of newly discovered readout errors in the electromagnetic calorimeter, which can haphazardly occur.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of the doubly Cabibbo-suppressed decays $D^+ → K^+π^0π^0$ and $D^+ → K^+π^0η$

By analyzing e + e - annihilation data corresponding to an integrated luminosity of 2.93 fb -1 collected at the center-of-mass energy of 3.773 GeV with the BESIII detector, we report the first observations of the doubly Cabibbo-suppressed decays D + → K + π 0 π 0 and D + → K + π 0 η. The branching fractions of D + → K + π 0 π 0 and D + → K + π 0 η are measured to be (2.1 ± 0.4 stat ± 0.1 syst ) x 10 -4 and (2.1 ± 0.5 stat ± 0.1 syst ) x 10 -4 with statistical significances of 8.8σ and 5.5σ, respectively. In addition, we search for the subprocesses D + → K * (892) + π 0 and D + → K * (892)+η with K * (892) + → K + π 0 . The branching fraction of D + → K * (892) + η is determined to be (4.4$^{+1.8}_{-1.5stat}$ ± 0.2 syst ) x 10 -4 , with a statistical significance of 3.2σ. No significant signal for D + → K * (892) + π 0 is found and we set an upper limit on the branching fraction of this decay at the 90% confidence level to be 5.4 x 10 -4 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗