Search NASA⌕ Search

Engineering topics

Akar, Sertac

Publications and source records attributed to Akar, Sertac.

At least 19 records

SolarAPP+ Performance Review: Final Technical Report

The National Renewable Energy Laboratory (NREL) and its project partners have developed the novel Solar Automated Permit Processing plus (SolarAPP+) software platform that provides a flexible, web-based PV-permitting tool for residential systems that can be integrated with existing and complementary software platforms. The main objective of this research is to analyze the implementation of SolarAPP+. Analysis was conducted by identifying the benefits, tradeoffs, and overall performance of SolarAPP+, including achieving its goals of delivering automated, code compliant systems, influencing permitting cycle times, and improving application submittals and/or inspection performance. The NREL team published the results of this analysis in annual SolarAPP+ Performance Review technical reports.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

RePED 250: A Revolutionary, High Drilling Rate, High-T Geothermal Drilling System and Companion Power Electronics (Final Report)

Geothermal drilling in the United States is drastically slower and more costly than Oil and Gas drilling, primarily due to the additional challenges in geothermal wells: hard rock types and high temperatures. The Repetitive Pulsed Electric Drill (250 degrees C) (RePED-250), developed by Tetra Corporation has the potential to change this with a novel electro-crushing technology. RePED-250 releases pulses of electricity through the rock, which causes it to break in tension, instead of compression like conventional rotary drilling. The tensile strength of hard rocks like granite is only ~5% of their compressive strength, requiring less energy, time, and wear on the bit than conventional drilling. The RePED drill bit has no moving parts, uses drilling mud to remove rock fragments, and standard drill pipe, enabling a direct transition from conventional drilling systems. The objective of this project is to move RePED technology towards commercial readiness for high-temperature geothermal applications. This involves: 1) Creating high-temperature, high power electronic components for the RePED drill capable of operating at the high temperatures of a geothermal well. The target is a 250 degrees C ambient environment. Specifically, capacitors, high voltage switches, and a downhole generator capable of generating the necessary power. 2) Demonstrating RePED's effectiveness drilling through hard rock (granite) and examining its pathway to commercialization and effect on the US geothermal market. Work on this project has led to significant improvement over the state-of-the-art for all the examined electronics, through design, modeling, and testing of these novel components, though some additional development is still needed to deploy these high-temperature parts in a geothermal well. Besides their use in RePED-250, each component has applications in other industries where the stability of electronics at high-temperature is needed. To address the second barrier to commercialization, a 9" hole was drilled through a sample block of granite, demonstrating the tool's effectiveness in hard rock. The team investigated RePED-250's effect on well cost, and the geothermal industry, through various models described in the report.

15 GEOTHERMAL ENERGY↗

SolarAPP+ Performance Review (2023 Data)

The Solar Automated Permit Processing Plus (SolarAPP+) platform is an online portal to facilitate and expedite rooftop solar photovoltaic (PV) and battery storage permitting processes. SolarAPP+ allows PV contractors to upload system specifications, have that information automatically reviewed for code compliance, and receive instant approval for code-compliant systems, reducing authority having jurisdiction (AHJ) staff time needed for review. SolarAPP+ also provides inspection checklists to verify installation practices and adherence to approved designs. SolarAPP+ is available to AHJs at no cost. This report is part of an ongoing series of reviews of SolarAPP+ performance. Consistent with previous performance reviews, we summarize SolarAPP+ adoption trends to date and compare various metrics for PV systems permitted through SolarAPP+ versus systems permitted through traditional AHJ permitting processes. As of the end of 2023, the National Renewable Energy Laboratory (NREL) had contacted over 1,700 AHJs with significant solar permitting volume regarding SolarAPP+. Of those, 793 AHJs had expressed interest in the platform as of the end of 2023. 161 AHJs had begun piloting the platform and 97 of these had publicly launched the platform by the end of 2023. In 2023, 668 installers submitted 18,906 permits through the SolarAPP+ platform, including 4,834 permits submitted as part of a solar plus storage program. SolarAPP+ permits accounted for around 43% of all permits issued in participating AHJs. We compare permitting timelines through SolarAPP+ to traditional AHJ permitting processes to assess the platform's performance. Consistent with previous SolarAPP+ performance reviews, we find that permitting timelines are significantly shorter for SolarAPP+ projects. Based on median timelines, a typical SolarAPP+ project is permitted and inspected 14.5 business days sooner than traditional projects. We estimate that automatic SolarAPP+ permitting saved around 7,200 hours of AHJ staff time in 2023. Finally, we estimate that SolarAPP+ eliminated over 150,000 business days in permitting-related delays in 2023.

14 SOLAR ENERGY↗

Techno-economic feasibility of geothermal energy production using inactive oil and gas wells for district heating and cooling systems in Tuttle, Oklahoma

Oil and gas wells have been drilled in the United States and often encounter hot co-produced water possibly suitable for geothermal direct-use applications. Here this study evaluated geothermal resources, heating and cooling demand, and techno-economic potential of four oil and gas wells repurposed for geothermal energy production to serve two public schools and 250 nearby houses in Tuttle, Oklahoma, USA. Subsurface geology in the study area primarily consists of Permian to Mississippian sandstone and limestone formations approximately from 2 km to 3.5 km depth. With a geothermal gradient of 25.3 °C/km, the temperature of geothermal energy production was estimated as 68.2 °C at 2.1 km. The potential of calcite scaling within boreholes and pipes was minimal. Using the characterized reservoir properties, techno-economic analyses were conducted for evaluating levelized costs of geothermal energy production for direct-use heating and cooling and district heating systems with five different production scenarios. Heating and cooling demand in two schools and 250 houses and additional 0.3 MW and 0.6 MW base heating loads for potential geothermal direct-use applications in the study area were also incorporated in the modeling. Results indicated that the levelized cost of heating of geothermal district heating systems utilizing existing wells were significantly lower than those of conventional geothermal energy systems that include well drillings. The geothermal energy production with doublet and quartet configurations was generally sufficient to supply total annual heating demand in the district, while a peaking boiler was used to supply peak loads. Doublet configurations showed higher production temperature with a lower thermal drawdown than the quartet configurations. The doublet system at 2.1 km production depth with 9.3 kg/s flow rate represented the optimal levelized cost of $71/MWh and 91.2% utilization factor. These results imply that the Tuttle geothermal district heating system is techno-economically feasible and comparable to geothermal district heating systems in the United States and the regional natural gas rate for residentials by recycling inactive oil and gas wells with no drillings.

15 GEOTHERMAL ENERGY↗

Analysis of Brackish Water Desalination for Municipal Uses: Case Studies on Challenges and Opportunities

Brackish water is a widely available, nontraditional water resource that can augment limited freshwater supplies. Although brackish water desalination has been continuously implemented in the United States and worldwide, it is necessary to reduce further its energy consumption, costs, and environmental impacts. This study conducted technoeconomic analyses to evaluate the current desalination and brine management technologies, focusing on the key factors and opportunities for sustainable brackish water desalination for municipal uses. Three case studies were selected as baseline representative of different geographic and operational conditions, including water quality, plant size, pretreatment, desalination, and concentrate management. Here, the technoeconomic analyses and model simulations identified challenges, opportunities, and research priorities to achieve specific pathways for enhanced brackish water desalination regarding levelized costs of water, electricity intensity, water recovery, zero liquid discharge, and brine valorization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WaterTAP3 Model Results for NAWI's Baseline Analyses

Description: This folder contains the results for the WaterTAP3 model that was used for the eight NAWI (National Alliance for Water Innovation) baseline studies published in the Environmental Science and Technology special issue: Technology Baselines and Innovation Priorities for Water Treatment and Supply. The data structure and content are described in a README.txt file. For more details on how to use the data and interpret the results please refer to the model documentation and GitHub site linked in the submission.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WaterTAP3 Model Input Data for NAWI's Eight Source Water Baseline Analyses

This folder contains the input data for the WaterTAP3 model that was used for the eight NAWI (National Alliance for Water Innovation) source water baselines studies published in the Environmental Science and Technology special issue: Technology Baselines and Innovation Priorities for Water Treatment and Supply. There are also eight other separate DAMS submissions, one per source water, that include the model results for the published studies. In this data submission, all model inputs across the eight baselines are included. The data structure and content are described in a README.txt file. For more details on how to use the data in WaterTAP3 please refer to the model documentation and GitHub site found at "WaterTAP3 Github" linked in the submission resources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pipe Parity Analysis of Seawater Desalination in the United States: Exploring Costs, Energy, and Reliability via Case Studies and Scenarios of Emerging Technology

As climate change-induced variables exacerbate water scarcities, the use of seawater reverse osmosis (SWRO) membrane desalination technology for treating seawater could potentially provide a long-term drought-proof source of drinking water. This study carried out a technoeconomic assessment (TEA) for three SWRO desalination plants in the U.S. and one in Israel to set baselines for the cost and energy consumption for seawater desalination. In addition, a breakeven curve for implementing SWRO desalination was estimated in relation to the cost of water conservation measures to meet drought-induced reduction of the traditional water supply. The results show that the cost of SWRO water production scales with the plant capacity while energy intensity is not dramatically different across the plants. The higher cost in some U.S. plants is due to high capital investment, including land acquisition and permitting. Variations in plant capacity utilization have the greatest impact on the levelized cost of water (LCOW) over the plant service life, suggesting the importance of reducing fouling and maintenance-related downtime. Scenario analysis of fixed labor cost reduction through process automation indicates investments in automation and sensing technology could result in long-term savings. Breakeven analysis shows the decision to adopt SWRO is highly dependent on the local cost associated with water conservation to meet water supply reduction. Moreover, a small reduction in SWRO cost can influence a shift toward the adoption of SWRO over water conservation measures. Incorporation of future water demand, water conservation potential, and water stress data around the nation indicates SWRO desalination could be an important contributor to the future municipal drinking water portfolio in the U.S.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost and Energy Metrics for Municipal Water Reuse

Municipal water reuse can contribute to a circular water economy in different contexts and with various treatment trains. This study synthesized information regarding the current technological and regulatory statuses of municipal reuse. It provides process-level information on cost and energy metrics for three potable reuse and one nonpotable reuse case studies using the new Water Techno-economic Assessment Pipe-Parity Platform (WaterTAP3). WaterTAP3 enabled comparisons of cost and energy metrics for different treatment trains and for different alternative water sources consistently with a common platform. A carbon-based treatment train has both a lower calculated levelized cost of water (LCOW) ($0.40/m3) and electricity intensity (0.30 kWh/m3) than a reverse osmosis (RO)-based treatment train ($0.54/m3 and 0.84 kWh/m3). In comparing LCOW and energy intensity for water production from municipal reuse, brackish water, and seawater based on the largest facilities of each type in the United States, municipal reuse had a lower LCOW and electricity than seawater but higher values than for production from brackish water. For a small (2.0 million gallon per day) inland RO-based municipal reuse facility, WaterTAP3 evaluated different deep well injection and zero liquid discharge (ZLD) scenarios for management of RO concentrate. Adding ZLD to a facility that currently allows surface discharge of concentrate would approximately double the LCOW. For all four case studies, LCOW is most sensitive to changes in weighted average cost of capital, on-stream capacity, and plant life. Baseline assessments, pipe parity metrics, and scenario analyses can inform greater observability and understanding of reuse adoption and the potential for cost-effective and energy-efficient reuse.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Annual Technology Baseline: The 2021 Electricity Update [Slides]

Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), the National Renewable Energy Laboratory annually provides an organized and centralized set of such cost and performance data. The ATB uses the best information from the Department of Energy national laboratories' renewable energy analysts. The ATB has been reviewed by experts and it includes the following electricity generation technologies: land-based wind, offshore wind, utility-scale solar photovoltaics (PV), commercial-scale solar PV, PV plus storage, residential-scale solar PV, concentrating solar power, geothermal power, hydropower, utility-scale battery storage, coal, and natural gas. EIA data for nuclear and conventional biopower are included for reference. This webinar presentation introduces the 2021 update to the ATB Electricity data and documentation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2021 Annual Technology Baseline (ATB) Cost and Performance Data for Electricity Generation Technologies

Starting in 2015 NREL has presented the Annual Technology Baseline (ATB) in an Excel workbook that contains detailed cost and performance data, both current and projected, for renewable and conventional technologies. The workbook includes a spreadsheet for each technology. This version of the workbook provides the final updates to data for the 2021 ATB. In 2019 and 2020, NREL has also provided selected data in Tableau workbooks and structured summary csv files. The data for 2015 - 2020 is located on https://data.nrel.gov. In 2021 and going forward, the data is cloud optimized and provided in the OEDI data lake. A website documents this and future data at https://atb.nrel.gov.

Array↗

WaterTAP3 (The Water Technoeconomic Assessment Pipe-Parity Platform)

The Water Technoeconomic Assessment Pipe-Parity Platform (WaterTAP3) was developed under the National Alliance for Water Innovation (NAWI) to facilitate consistent technoeconomic assessments of desalination treatment trains. The WaterTAP3 is an analytically robust modeling tool that can be used to evaluate water technology cost, energy, environmental, and resiliency tradeoffs across different water sources, sectors, and scales. The model simulates steady-state water treatment train performance and costs including flow and constituent mass balance across unit processes, based on source water conditions, configurations of treatment technologies, and system-level techno-economic assumptions. Users can build a new treatment train by connecting any number of unit processes, specific for their context and system, or selecting a train from the treatment train library. The model contains various technical and cost parameter options for a range of treatment processes and a library of influent water quality characteristics for a variety of source waters and case studies. Users can customize water quality parameters to evaluate the technology performance in their context. The model can be set up for different assessment needs including simulation, optimization, and uncertainty and sensitivity analyses. The results from WaterTAP3 can help identify trade-offs among the different system performance metrics, with insight on how particular technologies or systems promote pipe-parity. The flexibility and comprehensive scope of the tool makes it a promising solution to industry-wide water technoeconomic evaluations, leading to more informed water investment decisions and technologies. As a user-friendly, open-source platform, WaterTAP3 can be used by industry, academia, policymakers, planners, and those with or without extensive analytical experience.

Miara, Ariel↗

Water Technoeconomic Assessment Pipe-Parity Platform (WaterTAP3)

The Water Technoeconomic Assessment Pipe-Parity Platform (WaterTAP3) was developed under the National Alliance for Water Innovation (NAWI) to facilitate consistent technoeconomic assessments of desalination treatment trains. The WaterTAP3 is an analytically robust modeling tool that can be used to evaluate water technology cost, energy, environmental, and resiliency tradeoffs across different water sources, sectors, and scales. The model simulates steady-state water treatment train performance and costs including flow and constituent mass balance across unit processes, based on source water conditions, configurations of treatment technologies, and system-level techno-economic assumptions. Users can build a new treatment train by connecting any number of unit processes, specific for their context and system, or selecting a train from the treatment train library. The model contains various technical and cost parameter options for a range of treatment processes and a library of influent water quality characteristics for a variety of source waters and case studies. Users can customize water quality parameters to evaluate the technology performance in their context. The model can be set up for different assessment needs including simulation, optimization, and uncertainty and sensitivity analyses. The results from WaterTAP3 can help identify trade-offs among the different system performance metrics, with insight on how particular technologies or systems promote pipe-parity. The flexibility and comprehensive scope of the tool makes it a promising solution to industry-wide water technoeconomic evaluations, leading to more informed water investment decisions and technologies. As a user-friendly, open-source platform, WaterTAP3 can be used by industry, academia, policymakers, planners, and those with or without extensive analytical experience. A publicly available graphical user interface is currently under development.

Miara, Ariel↗

Preparing Distribution Utilities for Utility-Scale Storage and Electric Vehicles: A Novel Analytical Framework

Emerging distributed energy resources (DERs)—such as solar photovoltaics (PV), battery energy storage systems (BESS), and electric vehicles (EVs)—are expected to increase substantially in India in the coming years following policy-driven targets of the Government of India to modernize its electricity system, reduce greenhouse gas emissions (GHGs), and improve air quality. These emerging technologies can pose challenges to distribution utilities, forcing overhauls in planning and operational practices. They can also create challenges in power system infrastructure planning and cause more frequent system operational violations (e.g., network voltage bounds and loading thresholds) if not properly integrated. The impacts on the localized power distribution grid from these emerging technologies manifest in increased infrastructure investments and erratic shifts in demand patterns. These impacts are not yet well understood, and analytic solutions are not readily available. To address these challenges, the National Renewable Energy Laboratory (NREL), in collaboration with BSES Rajdhani Power Ltd. (BRPL), developed an advanced power distribution system impact analysis framework of BRPL’s distribution system. This framework helps analyze the readiness of the power distribution network to accommodate emerging technologies and the potential opportunities they might introduce. The framework has been predominantly set up to evaluate distributed PV, BESS, and EVs. In this collaboration between NREL and BRPL, we developed and evaluated the framework on two distribution feeders in the BRPL territory for various scenarios of BESS and EVs. BESS are evaluated for their effectiveness on the grid to mitigate present and future feeder overloading scenarios, and they are subsequently analyzed for their costs compared to the costs of traditional upgradation measures. Scenarios include assessing the effects of EV density on grid infrastructure upgrades and interlinking EV management with BESS integration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geothermal Deep Direct Use for Turbine Inlet Cooling in East Texas

The National Renewable Energy Laboratory (NREL), the Southern Methodist University Geothermal Laboratory (SMU), Eastman Chemical (Longview, TX), and TAS (Houston, TX) evaluated the feasibility of using geothermal heat to improve the performance of a natural-gas power plant in East Texas. The area of interest is the Eastman Chemical plant in Longview, Texas, which is on the northwestern margin of a geologic region known as the Sabine Uplift. The feasibility study focused on determining the potential for accessing a subsurface hot-water geothermal resource within a 10-km radius of the site to provide thermal energy for absorption chillers. Wells within a 20-km radius are included for broader geological comparison to determine the heat flow, temperature-at-depth, field porosity and permeability. The lithologies of most interest are the Lower Cretaceous Trinity Group and Upper Jurassic Cotton Valley Group. The deeper Cotton Valley formations are hotter (averaging 117 to 130°C), yet permeability and porosity are low. The shallower Trinity Group contains more variability in permeability and porosity and lower temperatures averaging about 98 to 117°C. The shallower formations are considered despite the lower temperature because of increased ability to produce larger volumes of water and extract enough heat before reinjection. The complete SMU analysis is available in the National Geothermal Data System (NGDS). Tapping such deep geothermal sources for direct heating (as opposed to power generation) is known as geothermal deep direct use (DDU). Geothermal DDU has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for what are typically small-scale, variable-demand projects. This project examines the feasibility of geothermal energy integration in a natural-gas combined cycle power station in East Texas. The DDU resource is tapped to drive absorption chillers (24/7) for production of chilled water at 5-10°C (41-50°F). This chilled water is stored until needed, which allows for continuous operation with a relatively small-capacity geothermal/absorption chiller system. When conditions are favorable, the chilled water is dispatched to cool the air entering the compressor stage of a gas combustion turbine. This process, known as turbine inlet cooling (TIC), boosts power production during periods of high temperature and high-power demand. Such systems can enhance grid reliability and reduce the cost for peak-demand power. A simulation model of the power plant was developed in IPSEpro software and validated against operational data from the plant. This model allowed the team to estimate the additional power that could be produced by applying TIC under different operating and ambient conditions. Absorption chiller performance was estimated from vendor sources to determine the production rate of chilled water from the geothermal resource. Geothermal drilling and development costs were estimated using NREL's GEOPHIRES 2.0. The expected lower drilling costs in this region led to an estimated cost of geothermal heat of about $4/MMBtu (1.4 cents/kWh t ). The estimated cost for the absorption chillers and TIC hardware were obtained from literature sources and project partners. Hourly data were obtained for weather, natural gas and electricity prices, and plant operating state for 2017, which served as a representative year. NREL estimated the capital cost, operating cost, and additional electricity production and revenue for different combinations of geothermal capacity, chiller capacity, and water storage-tank size. The analysis drove toward smaller geothermal and chiller systems to reduce equipment cost. A relatively low-cost water storage tank accumulated the near-continuous chilled water output for later use when TIC was most valued.

15 GEOTHERMAL ENERGY↗

Why Wideband Gap Needs Techno-Economics

The wideband gap community when discussing projects antidotally refers to the cost of the technology, frequently noting the higher wideband gap upfront cost in comparison to the incumbent state of art. Other technologies such as photovoltaics have embraced techno-economics analysis (TEA) as a method of analytically articulating the impacts of research advancements on system performance and lifetime costs. Our TEA shows the potential impact of research advancements on Gallium Oxide (Ga2O3) and Silicon Carbide (SiC) wafer manufacturing cost, the impact on the levelized cost of electricity (LCOE) when using a SiC based solar inverter, and lastly how the high cost of devices (SiC in this case) can be offset by other system cuts, such as the footprint and cooling reductions in a 1MW variable frequency motor drive. The specific goal is to show analytically the lifetime cost and performance benefits of adopting wideband gap technology whether it is at the device level or it is cumulative benefit though a simplified balance of system.

14 SOLAR ENERGY↗

Performance and Techno-Economic Evaluation of a Three-Phase, 50-kW SiC-Based PV Inverter

The technical capabilities and benefits of silicon carbide (SiC) compared to silicon (Si) based power electronics converters as well as the premium associated with using SiC instead of Si are well understood. This work proves that the benefits provided by SiC, such as increased efficiency, would result in a lower levelized cost of energy (LCOE) compared to both commercially available, state-of-the-art inverters and the benchmark commercial system cost calculated for the U.S. Department of Energy Solar Energy Technologies Office's SunShot program. The LCOE is calculated to be same as the commercial benchmark despite the installed system cost being 8% more than the benchmark. The LCOE calculation is based on both experiential values obtained from testing the SiC photovoltaic (PV) inverter and on the bottoms-up modeled volume cost for the same 50-kW SiC-based inverter. The PV system used for the LCOE model is also explained, and the system cost breakout is presented in this paper. Furthermore, multiple scenarios with variations in the PV system are presented to show their effect on the system LCOE.

14 SOLAR ENERGY↗