Search NASA⌕ Search

Engineering topics

Akkurt, Hatice

Publications and source records attributed to Akkurt, Hatice.

Accelerated Corrosion Tests to Evaluate Long-Term Performance of BORAL{sup R} in Spent Fuel Pools

Neutron absorber materials are used to increase storage capacity in spent fuel pools (SFPs) while maintaining criticality safety margins. BORAL{sup R} - a neutron absorber material commonly used in SFPs - is a metal matrix composite containing boron carbide (B{sub 4}C) and Al-1100 mixture. The aluminum (Al) cladding, which is on both sides of the core, serves as a protective barrier. Al cladding is susceptible to corrosion, which can lead to blisters between the core material and the cladding over time. Based on operational experience to date, pits also have been observed via visual examination and microscopy. EPRI has maintained a database containing coupon data spanning more than 25 years, and to date no loss of BORAL{sup R} efficacy has been observed. In the United States, about 50% of the plants use BORAL{sup R} as neutron absorber material in SFPs. BORAL{sup R} is also used in nuclear plants in Mexico, Korea, Taiwan, and other countries. Given that the plant lifetime is increasing-and, hence, the SFP lifetime-EPRI initiated a five-year accelerated corrosion test in 2013 to evaluate and determine the long-term performance of BORAL{sup R} in SFPs. This paper presents an overview of the accelerated corrosion test project. Results from the Year 1 and Year 2 test results are also presented. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Neutron Absorber Panels from Zion Spent Fuel Pool

In spent fuel pools (SFPs), fixed neutron absorber materials are used to increase storage capacity while maintaining criticality safety margins. BORAL{sup R} is a commonly used neutron absorber material for both wet (SFPs) and dry storage (casks). The specific questions surrounding fixed neutron absorber materials include the following: 1. What are the conditions of the neutron absorber panels in SFPs? Is there any gross degradation that could cause potential concern for criticality safety of the pools? 2. Is the coupon monitoring approach adequate for monitoring the conditions of the panels as part of an aging management program? 3. For plants that do not have coupons, do current in situ measurement approaches provide accurate results? Could such in situ approaches be used as an alternative monitoring approach? In order to shed light on these technical questions using actual plant data, EPRI initiated the Zion comparative analysis project at the decommissioning Zion Nuclear Power Plant in late 2014. An overview of the Zion plant, SFP, and project was described in a previous publication. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overview of zion comparative analysis project for assessment of Boral{sup R} neutron absorber material performance and monitoring in spent fuel pools - 14618

Neutron absorber materials are used in spent fuel pool (SFP) storage racks to control reactivity. In the United States, about half of the operating plants currently use BORAL{sup R} neutron absorber material in SFP racks. Although operational experience spanning more than 25 years has not shown any loss of the BORAL{sup R} core material, corrosion effects, including blisters and pits, have been observed and reported. To improve understanding for the behavior of BORAL{sup R} in SFPs and evaluate the performance of monitoring approaches, EPRI initiated the Zion comparative analysis project in 2014. The Zion project involves three phases. During the first phase of the project, in situ measurements were performed on selected SFP rack panels in December 2014. Panels for in situ measurements were selected after an extensive analysis of each panel in the pool to ensure that the selected panels represented the pool in terms of variation in neutron and gamma dose values. As part of the second phase of the project, the remaining 10 coupons from the Zion SFP were shipped to a Penn State University (PSU) laboratory for analysis in January 2015. During the final phase of the project, a subset of the panels for which in situ measurements were performed will be harvested from the Zion SFP, cut into samples, and analyzed at PSU. The overall scope of this project will allow comparison of in situ measurements to real panel data as well as data obtained from coupon analysis. In this paper, an overview of the Zion comparative analysis project, the criteria and procedure for panel selection for in situ measurements and harvesting, preliminary coupon analysis results and in situ measurement results are presented. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Overview of neutron absorber materials used in spent fuel pools - 14622

Spent fuel pools (SFPs) were originally designed with low density storage racks that maintained subcriticality based on geometric separation. With the increasing need for storage, due to elimination of reprocessing as a viable alternative, SFPs with high-density racks required neutron absorber materials to control reactivity and maintain criticality safety margins. The Nuclear Energy Institute (NEI) conducted an industry wide survey in 2013 and the survey was updated recently based on additional utility data provided by Electric Power Research Institute (EPRI). The survey results show that about one-quarter of the pools in the United States either do not have neutron absorber material in the SFP or do not credit it even when it is present. Also, about half of the plants in the U.S. use BORAL{sup R} as the neutron absorber material followed by Metamic, Carborundum, Alcan, and borated stainless steel. For neutron absorber monitoring, the majority of the plants rely on a coupon testing program. However, for those plants that never installed coupons or have exhausted their supply of coupons from coupon sampling, in situ measurements at periodic intervals can be performed to determine the status of the neutron absorber. In this paper, an overview of the types of neutron absorber materials used in SFPs, the distribution of absorber material use by material type, types of monitoring programs as part of aging management programs, operational experience to date with different absorber materials based on monitoring programs, and industry initiatives toward addressing long-term performance issues related to neutron absorber material degradation and monitoring are presented. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Characterization of Scintillator Performance at Temperatures up to 400 Degrees Centigrade

The logging and characterization of geothermal wells requires improved scintillator systems that are capable of operation at temperatures significantly above those commonly encountered in the logging of most conventional oil and gas wells (e.g., temperatures nominally in the range of up to 150oC.) Unfortunately, most of the existing data on the performance of scintillators for radiation detection at elevated temperatures is fragmentary, uncorrelated, and generally limited to relatively low temperatures in most cases to temperatures well below 200oC. We have designed a system for characterizing scintillator performance at temperatures extending up to 400oC under inert atmospheric conditions, and this system is applied here to the determination of scintillator performance at elevated temperatures for a wide range of scintillators including, among others: bismuth germanate, cadmium tungstate, cesium iodide, cesium iodide (Tl), cesium iodide (Na), sodium iodide, sodium iodide (Tl), lutetium oxy-orthosilicate (Ce), zinc tungstate, yttrium aluminum perovskite (Ce), yttrium aluminum garnet (Ce), lutetium aluminum perovskite (Ce), and barium fluoride, strontium iodide(Eu). The results of these high-temperature scintillator performance tests are described in detail here. Comparisons of the relative elevated-temperature properties of the various scintillator materials have resulted in the identification of promising scintillator candidates for high-temperature use in geothermal and fossil-fuel well environments.

gamma ray↗

Recent Updates to Radiation Organ Dose Estimation Tool PIMAL

A computational phantom with moving arms and legs and an accompanying graphical user interface, PIMAL, was previously developed to enable radiation dose estimation for different postures in a user-friendly manner. This initial version of the software was useful in adjusting the posture, generating the corresponding MCNP input file, and performing the radiation transport simulations for dose calculations using MCNP5 or MCNPX. However, it only included one mathematical phantom model (hermaphrodite) and allowed only isotropic point sources. Recently, the software was enhanced by adding two more mathematical phantom models, a male and female, and the source features were enhanced significantly by adding internal and external source options in a pull-down menu. Although the initial version of the software included only a mathematical hermaphrodite phantom, the features and models in the software are constantly being enhanced by adding more phantoms as well as other options to enable dose assessment for different configurations/cases in a user-friendly manner. In this latest version of the software, ICRP's recently released reference male and female voxel phantoms are included in a pull-down menu. The male and female models are described using 7 and 14 million voxels, respectively. Currently, the software is being modified further to include the International Commission on Radiation Protection's (ICRP) reference male and female voxel phantoms. Additionally, some case studies are being implemented and included in a library of input files. This paper describes recent updates to the software.

59 BASIC BIOLOGICAL SCIENCES↗

Radiation Dose Estimation Using Realistic Postures with PIMAL

For correct radiation dose assessment, it is important to take the posture into account. A computational phantom with moving arms and legs was previously developed to address this need. Further, an accompanying graphical user interface (GUI), called PIMAL, was developed to enable dose estimation using realistic postures in a user-friendly manner such that the analyst's time could be substantially reduced. The importance of the posture for correct dose estimation has been demonstrated with a few case studies in earlier analyses. The previous version of PIMAL was somewhat limited in its features (i.e., it contained only a hermaphrodite phantom model and allowed only isotropic source definition). Currently GUI is being further enhanced by incorporating additional phantom models, improving the features, and increasing the user friendliness in general. This paper describes recent updates to the PIMAL software. In this summary recent updates to the PIMAL software, which aims to perform radiation transport simulations for phantom models in realistic postures in a user-friendly manner, are described. In future work additional phantom models, including hybrid phantom models, will be incorporated. In addition to further enhancements, a library of input files for the case studies that have been analyzed to date will be included in the PIMAL.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of Neutron Detector Response to Varying Temperature and Water Content for Geothermal Applications

Nuclear logging techniques have been used for oil well logging applications for decades. The basic principle is to use a neutron and/or photon source and neutron and photon detectors for characterization purposes. Although the technology has matured, it is not directly applicable to geothermal logging due to even more challenging environmental conditions, both in terms of temperature and pressure. For geothermal logging, the operating temperature can go up to 376 C for depths up to 10,000 km. In this paper, the preliminary computational results for thermal neutron detector response for varying temperature and water content for geothermal applications are presented. In this summary, preliminary results for neutron detector response for varying formation temperature and water content are presented. The analysis is performed for a steady state source (AmBe) and time dependent source (PNG) in pulsed mode. The computational results show significant sensitivity to water content as well as temperature changes for both steady state and time dependent measurements. As expected, the most significant change is due to the temperature change for S({alpha}, {beta}) nuclear data instead of individual isotope cross sections for the formation. Clearly, this is partially because of the fact that strong absorbers (i.e., chlorine) are not taken into account for the analysis at this time. The computational analysis was performed using the temperature dependent data in the ENDF/B-VII libraries, supplied with MCNP. Currently, the data for intermediate temperatures are being generated using NJOY and validated. A series of measurements are planned to validate the computational results. Further measurements are planned to determine the neutron and photon detector response as a function of temperature. The tests will be performed for temperatures up to 400 C.

02 PETROLEUM↗

Personnel Dose Assessment during Active Interrogation

A leading candidate in the detection of special nuclear material (SNM) is active interrogation (AI). Unlike passive interrogation, AI uses a source to enhance or create a detectable signal from SNM (usually fission), particularly in shielded scenarios or scenarios where the SNM has a low activity. The use of AI thus makes the detection of SNM easier or, in some scenarios, even enables previously impossible detection. During the development of AI sources, significant effort is put into determining the source strength required to detect SNM in specific scenarios. Usually during this process, but not always, an evaluation of personnel dose is also completed. In this instance personnel dose could involve any of the following: (1) personnel performing the AI; (2) unknown stowaways who are inside the object being interrogated; or (3) in clandestine interrogations, personnel who are known to be inside the object being interrogated but are unaware of the interrogation. In most instances, dose to anyone found smuggling SNM will be a secondary issue. However, for the organizations performing the AI, legal if not moral considerations should make dose to the personnel performing the AI, unknown stowaways, or innocent bystanders in clandestine interrogations a serious concern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗