Process modeling guides operational variables that affect CO 2 utilization during the accelerated carbonation of concrete
Abstract Accelerated concrete carbonation is an expanding option for decarbonizing construction. Factors such as concrete mixture design and carbonation environment can influence the maximum CO 2 utilization that can be achieved during such a process. A carbonation process designed to utilize a water‐saturated dilute CO 2 source wherein 2 < CO 2 concentration (v/v%) < 16, was modeled in AspenPlus©. A regression model was developed to correlate CO 2 uptake, relative humidity (11%–100%), CO 2 concentration ([CO 2 ] = 2—16 v/v%), and temperature ( T = 11–74°C) conditions within a carbonation reactor. It was determined that [CO 2 ] was the most significant variable as higher concentrations enhanced CO 2 transport through the concrete. The energy use intensity per mass of CO 2 utilized (kWh/kgCO 2 ) was determined across a range of processing conditions. As a function of the operational conditions, accelerated carbonation provides a net CO 2 reduction of up to 28 kgCO 2 /tonne of concrete; a reduction of up to ~45% compared to typical formulations.