Search NASA⌕ Search

Engineering topics

Albertini, Francesca

Publications and source records attributed to Albertini, Francesca.

Robustness of the Voluntary Breath-Hold Approach for the Treatment of Peripheral Lung Tumors Using Hypofractionated Pencil Beam Scanning Proton Therapy

Purpose: The safe clinical implementation of pencil beam scanning (PBS) proton therapy for lung tumors is complicated by the delivery uncertainties caused by breathing motion. The purpose of this feasibility study was to investigate whether a voluntary breath-hold technique could limit the delivery uncertainties resulting from interfractional motion. Methods and Materials: Data from 15 patients with peripheral lung tumors previously treated with stereotactic radiation therapy were included in this study. The patients had 1 computed tomographic (CT) scan in voluntary breath-hold acquired before treatment and 3 scans during the treatment course. PBS proton treatment plans with 2 fields (2F) and 3 fields (3F), respectively, were calculated based on the planning CT scan and subsequently recalculated on the 3 repeated CT scans. Recalculated plans were considered robust if the V{sub 95%} (volume receiving ≥95% of the prescribed dose) of the gross target volume (GTV) was within 5% of what was expected from the planning CT data throughout the simulated treatment. Results: A total of 14/15 simulated treatments for both 2F and 3F met the robustness criteria. Reduced V{sub 95%} was associated with baseline shifts (2F, P=.056; 3F, P=.008) and tumor size (2F, P=.025; 3F, P=.025). Smaller tumors with large baseline shifts were also at risk for reduced V{sub 95%} (interaction term baseline/size: 2F, P=.005; 3F, P=.002). Conclusions: The breath-hold approach is a realistic clinical option for treating lung tumors with PBS proton therapy. Potential risk factors for reduced V{sub 95%} are small targets in combination with large baseline shifts. On the basis of these results, the baseline shift of the tumor should be monitored (eg, through image guided therapy), and appropriate measures should be taken accordingly. The intrafractional motion needs to be investigated to confirm that the breath-hold approach is robust.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Robustness to Setup and Range Uncertainties for Head and Neck Patients Treated With Pencil Beam Scanning Proton Therapy

Purpose: To evaluate the robustness of head and neck plans for treatment with intensity modulated proton therapy to range and setup errors, and to establish robustness parameters for the planning of future head and neck treatments. Methods and Materials: Ten patients previously treated were evaluated in terms of robustness to range and setup errors. Error bar dose distributions were generated for each plan, from which several metrics were extracted and used to define a robustness database of acceptable parameters over all analyzed plans. The patients were treated in sequentially delivered series, and plans were evaluated for both the first series and for the combined error over the whole treatment. To demonstrate the application of such a database in the head and neck, for 1 patient, an alternative treatment plan was generated using a simultaneous integrated boost (SIB) approach and plans of differing numbers of fields. Results: The robustness database for the treatment of head and neck patients is presented. In an example case, comparison of single and multiple field plans against the database show clear improvements in robustness by using multiple fields. A comparison of sequentially delivered series and an SIB approach for this patient show both to be of comparable robustness, although the SIB approach shows a slightly greater sensitivity to uncertainties. Conclusions: A robustness database was created for the treatment of head and neck patients with intensity modulated proton therapy based on previous clinical experience. This will allow the identification of future plans that may benefit from alternative planning approaches to improve robustness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimum time optimal synthesis for two level quantum systems

For the time optimal problem of an invariant system on SU(2), with two independent controls and a bound on the norm of the control, the extremals of the Pontryagin maximum principle are explicit functions of time. We use this fact here to perform the optimal synthesis for these systems, i.e., to find all time optimal trajectories. Although the Lie group SU(2) is three dimensional, time optimal trajectories can be described in the unit disk of the complex plane. We find that a circular trajectory separates optimal trajectories that reach the boundary of the unit disk from the others. Inside this separatrix circle, another trajectory (the critical trajectory) plays an important role in that all optimal trajectories end at an intersection with this curve. The results allow us to find the minimum time needed to achieve a given evolution of a two level quantum system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spot-Scanning Proton Radiation Therapy for Pediatric Chordoma and Chondrosarcoma: Clinical Outcome of 26 Patients Treated at Paul Scherrer Institute

Purpose: To evaluate the clinical results of fractionated spot-scanning proton radiation therapy (PT) in 26 pediatric patients treated at Paul Scherrer Institute for chordoma (CH) or chondrosarcoma (CS) of the skull base or axial skeleton. Methods and Materials: Between June 2000 and June 2010, 19 CH and 7 CS patients with tumors originating from the skull base (17) and the axial skeleton (9) were treated with PT. Mean age at the time of PT was 13.2 years. The mean prescribed dose was 74 Gy (relative biological effectiveness [RBE]) for CH and 66 Gy (RBE) for CS, at a dose of 1.8-2.0 Gy (RBE) per fraction. Results: Mean follow-up was 46 months. Actuarial 5-year local control (LC) rates were 81% for CH and 80% for CS. Actuarial 5-year overall survival (OS) was 89% for CH and 75% for CS. Two CH patients had local failures: one is alive with evidence of disease, while the other patient succumbed to local recurrence in the surgical pathway. One CS patient died of local progression of the disease. No high-grade late toxicities were observed. Conclusions: Spot-scanning PT for pediatric CH and CS patients resulted in excellent clinical outcomes with acceptable rates of late toxicity. Longer follow-up time and larger cohort are needed to fully assess tumor control and late effects of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose to the Developing Dentition During Therapeutic Irradiation: Organ at Risk Determination and Clinical Implications

Purpose: Irradiation of pediatric facial structures can cause severe impairment of permanent teeth later in life. We therefore focused on primary and permanent teeth as organs at risk, investigating the ability to identify individual teeth in children and infants and to correlate dose distributions with subsequent dental toxicity. Methods and Materials: We retrospectively reviewed 14 pediatric patients who received a maximum dose >20 Gy(relative biological effectiveness, RBE) to 1 or more primary or permanent teeth between 2003 and 2009. The patients (aged 1-16 years) received spot-scanning proton therapy with 46 to 66 Gy(RBE) in 23 to 33 daily fractions for a variety of tumors, including rhabdomyosarcoma (n=10), sarcoma (n=2), teratoma (n=1), and carcinoma (n=1). Individual teeth were contoured on axial slices from planning computed tomography (CT) scans. Dose-volume histogram data were retrospectively obtained from total calculated delivered treatments. Dental follow-up information was obtained from external care providers. Results: All primary teeth and permanent incisors, canines, premolars, and first and second molars were identifiable on CT scans in all patients as early as 1 year of age. Dose-volume histogram analysis showed wide dose variability, with a median 37 Gy(RBE) per tooth dose range across all individuals, and a median 50 Gy(RBE) intraindividual dose range across all teeth. Dental follow-up revealed absence of significant toxicity in 7 of 10 patients but severe localized toxicity in teeth receiving >20 Gy(RBE) among 3 patients who were all treated at <4 years of age. Conclusions: CT-based assessment of dose distribution to individual teeth is feasible, although delayed calcification may complicate tooth identification in the youngest patients. Patterns of dental dose exposure vary markedly within and among patients, corresponding to rapid dose falloff with protons. Severe localized dental toxicity was observed in a few patients receiving the largest doses of radiation at the youngest ages; however, multiple factors including concurrent chemotherapy confounded the dose-effect relationship. Further studies with larger cohorts and appropriate controls will be required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spot-Scanning-Based Proton Therapy for Extracranial Chordoma

Purpose: To evaluate effectiveness and safety of spot-scanning-based proton-radiotherapy (PT) for extracranial chordomas (ECC). Methods and Material: Between 1999-2006, 40 patients with chordoma of C-, T-, and L-spine and sacrum were treated at Paul Scherrer Institute (PSI) with PT using spot-scanning. Median patient age was 58 years (range, 10-81 years); 63% were male, and 36% were female. Nineteen patients (47%) had gross residual disease (mean 69 cc; range, 13-495 cc) before PT, and 21 patients (53%) had undergone prior titanium-based surgical stabilization (SS) and reconstruction of the axial skeleton. Proton doses were expressed as Gy(RBE). A conversion factor of 1.1 was used to account for higher relative biological effectiveness (RBE) of protons compared with photons. Mean total dose was 72.5 Gy(RBE) [range, 59.4-75.2 Gy(RBE)] delivered at 1.8-2.0 Gy(RBE) dose per fraction. Median follow-up time was 43 months. Results: In 19 patients without surgical stabilization, actuarial local control (LC) rate at 5 years was 100%. LC for patients with gross residual disease but without surgical stabilization was also 100% at 5 years. In contrast, 12 failures occurred in 21 patients with SS, yielding a significantly decreased 5-year LC rate of 30% (p = 0.0003). For the entire cohort, 5-year LC rates were 62%, disease-free survival rates were 57%, and overall survival rates were 80%. Rates were 100% for patients without SS. No other factor, including dosimetric parameters (V95, V80) were predictive for tumor control on univariate analysis. Conclusion: Spot-scanning-based PT at PSI delivered subsequently to function-preserving surgery for tumor debulking, decompression of spinal cord, or biopsy only is safe and highly effective in patients with ECC without major surgical instrumentation even in view of large, unresectable disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗