Report of the Third Biomedical Confidence Building Exercise
Abstract not provided
Engineering topics
Publications and source records attributed to Alcaraz, A.
Abstract not provided
We participated in the first exercise to build confidence in the analysis of biomedical samples for trace levels of CW agents and/or their degradation, reaction or metabolites.
Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limit of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.
The sample received from Picatinny Arsenal was analyzed for trace amounts of high explosives (HE). A complete wash of the surface was performed, concentrated, and analyzed using two sensitive analysis techniques that are capable of detecting numerous types of explosives. No explosives were detected with either test.