Validation of On-Orbit Methodology for the Assessment of Cardiac Function and Changes in the Circulating Volume Using "Braslet-M" Occlusion Cuffs

BACKGROUND: The transition to microgravity eliminates the hydrostatic gradients in the vascular system. The resulting fluid redistribution commonly manifests as facial edema, engorgement of the external neck veins, nasal congestion, and headache. This experiment examined the responses to modified Valsalva and Mueller maneuvers as measured by cardiac and vascular ultrasound in a baseline microgravity steady state, and under the influence of thigh occlusion cuffs (Braslet cuffs). METHODS: Nine International Space Station crewmember subjects (Expeditions 16 - 20) were examined in 15 experiment sessions 101 46 days after launch (mean SD; 33 - 185). 27 cardiac and vascular parameters were obtained under three respiratory conditions (baseline, Valsalva, and Mueller) before and after tightening of the Braslet cuffs for a total of 162 data points per session. The quality of cardiac and vascular ultrasound examinations was assured through remote monitoring and guidance by Investigators from the NASA Telescience Center in Houston, TX, USA. RESULTS: Fourteen of the 81 measured conditions were significantly different with Braslet application and were apparently related to cardiac preload reduction or increase in the venous volume sequestered in the lower extremity. These changes represented 10 of the 27 parameters measured. In secondary analysis, 7 of the 27 parameters were found to respond differently to respiratory maneuvers depending on the presence or absence of thigh compression, with a total of 11 differences. CONCLUSIONS: Acute application of Braslet occlusion cuffs causes lower extremity fluid sequestration and exerts proportionate measurable effects on cardiac performance in microgravity. Ultrasound techniques measuring the hemodynamic effects of thigh cuffs in combination with respiratory maneuvers may serve as an effective tool in determining the volume status of a cardiac or hemodynamically compromised patient in microgravity.

Hamilton, D. R.↗

Acute Modifications of Circulating Volume and Respiratory Maneuvers in the Cardiovascular Assessment of Long-Duration Crewmembers

This U.S. - Russian project is aimed at improved assessment of cardiac and vascular parameters associated with circulating volume and its distribution in long-duration space flight. Objective responses to modified Valsalva and Mueller maneuvers were measured by cardiac and vascular ultrasound before, during, and after temporary volume redistribution by means of Braslet-M thigh occlusion cuffs (Russia). Braslet-M cuffs are custom fitted to each crewmember prior to launch on the Soyuz as a Russian countermeasure for space adaptation fluid shifts

Bogomolov, V. V.↗

Right Ventricular Tissue Doppler Assessment in Space During Circulating Volume Modification using the Braslet-M Device

This joint U.S. - Russian work aims to establish a methodology for assessing cardiac function in microgravity in association with manipulation of central circulating volume. Russian Braslet-M occlusion cuffs were used to temporarily increase the volume of blood in the lower extremities, which effectively reduces the volume returning to the heart in the central circulation. A novel methodology was tested on the International Space Station (ISS) to assess the volume status of crewmembers by evaluating the responses to application and release of the Braslet-on-occlusion cuffs, as well as to modified Valsalva and Mueller maneuvers. Baseline echocardiographic tissue Doppler imaging (TDI) of the right ventricular free wall with no Braslet applied shows early diastolic E' (16 cm/sec), late diastolic A' (14 cm/sec), and systolic (12 cm/sec) velocities compatible with normal subjects on Earth. TDI of the RV free wall with Braslet applied shows that early diastolic E' decreased by 50% (8 cm/sec), late diastolic A' increased by 45%, and systolic S' remains unchanged. TDI of the RV free wall approximately 8 beats after the Braslet was released shows early diastolic E' (8 cm/sec), late diastolic A' (12 cm/sec), and systolic S' (13 cm/sec) velocities. During this portion of the release, early diastolic E' did not recover to baseline values but late diastolic A' and systolic S' recovered to pre-Braslet values. The pre-systolic cross-sectional area of the internal jugular vein with Braslet off was 1.07 cm(sup 2) and 1.13 cm(sup 2) 10 min after the Braslet was applied. The presystolic cross-sectional area of the common femoral vein with Braslet off was 0.50 cm(sup 2), and was 0.54 cm(sup 2) 10 min after the Braslet was applied. The right ventricular myocardial performance Tei index also was calculated for comparison with typical values found in healthy subjects on Earth. Baseline and Braslet-on values for Tei index were 0.25 and 0.22 respectively. Braslet Tei indices are within normal ranges found in healthy subjects and temporarily become greater than 0.4 during the dynamic Braslet release portion of this study. Tissue Doppler imaging of the right ventricle revealed that the Braslet influenced cardiac preload and that fluid was sequestered in the lower-extremity interstitial and vascular space after only 10 minutes of application. This report demonstrates that Braslet application affects right ventricular physiology in long-duration space flight based on TDI and that this effect is in part due to venous hemodynamics.

Hamilton, D. R.↗

Validation of On-Orbit Methodology for the Assessment of Cardiac Function and Changes in the Circulating Volume Using Ultrasound and "Braslet-M" Occlusion Cuffs

Recent advances in remotely guided imaging techniques on ISS allow the acquisition of high quality ultrasound data using crewmember operators with no medical background and minimal training. However, ongoing efforts are required to develop and validate methodology for complex imaging protocols to ensure their repeatability, efficiency, and suitability for use aboard the ISS. This Station Developmental Test Objective (SDTO) tests a cardiovascular evaluation methodology that takes advantage of the ISS Ultrasound capability, the Braslet-M device, and modified respiratory maneuvers (Valsalva and Mueller), to broaden the spectrum of anatomical and functional information on human cardiovascular system during long-duration space missions. The proposed methodology optimizes and combines new and previously demonstrated methods, and is expected to benefit medically indicated assessments, operational research protocols, and data collections for science. Braslet-M is a current Russian operational countermeasure that compresses the upper thigh to impede the venous return from lower extremities. The goal of the SDTO is to establish and validate a repeatable ultrasound-based methodology for the assessment of a number of cardiovascular criteria in microgravity. Braslet-M device is used as a means to acutely alter volume distribution while focused ultrasound measurements are performed. Modified respiratory maneuvers are done upon volume manipulations to record commensurate changes in anatomical and functional parameters. The overall cardiovascular effects of the Braslet-M device are not completely understood, and although not a primary objective of this SDTO, this effort will provide pilot data regarding the suitability of Braslet-M for its intended purpose, effects, and the indications for its use.

Bogomolov, V. V.↗