Search NASA⌕ Search

Engineering topics

Allen, Jeffery

Publications and source records attributed to Allen, Jeffery.

Generating multi-scale Li-ion battery cathode particles with radial grain architectures using stereological generative adversarial networks

Abstract Understanding structure-property relationships of Li-ion battery cathodes is crucial for optimizing rate-performance and cycle-life resilience. However, correlating the morphology of cathode particles, such as in LiNi0.8Mn0.1Co0.1O2 (NMC811), and their inner grain architecture with electrode performance is challenging, particularly, due to the significant length-scale difference between grain and particle sizes. Experimentally, it is not feasible to image such a high number of particles with full granular detail. A second challenge is that sufficiently high-resolution 3D imaging techniques remain expensive and are sparsely available at research institutions. Here, we present a stereological generative adversarial network-based model fitting approach to tackle this, that generates representative 3D information from 2D data, enabling characterization of materials in 3D using cost-effective 2D data. Once calibrated, this multi-scale model can rapidly generate virtual cathode particles that are statistically similar to experimental data, and thus is suitable for virtual characterization and materials testing through numerical simulations. A large dataset of simulated particles with inner grain architecture has been made publicly available.

25 ENERGY STORAGE↗

Using Parameter Sweep in WaterTAP to Analyze New Water Treatment Technologies

We describe a powerful and generalized parameter sweep tool in this report that was originally developed to analyze the performance of existing and novel water treatment models being developed in WaterTAP. Since WaterTAP is built upon IDAES and Pyomo, the parameter sweep tool can be used to systematically explore and debug the behavior of most Pyomo and IDAES numerical models. In order to enable meaningful analyses, the parameter sweep tool has been designed with the following features: 1) Model flexibility: The parameter sweep tool does not enforce any restrictions on the types of models that can be used with it. As long as a Pyomo model can be solved and the parameter is active and mutable, the tool only needs functions that describe how to run the model, the sweep parameters, and the output quantities of interest. 2) Flexible sampling: The parameter sweep tool has inbuilt functions to generate samples from a random distribution or a multidimensional Euclidean space. Furthermore, the users have to ability to supply samples generated from a tool of their choice. 3) Multiple sweep types: A user can choose from one of 3 types of parameter sweeps depending on their needs. 4) Detailed outputs: Outputs generated by the parameter sweep tool can be stored in detailed H5 file or user-friendly CSV files for post processing. 5) Parallel computing: The parameter sweep supports shared and distributed memory parallel computing to enable the use of high performance computers (HPC) for large-scale analyses. 6) Modular: The parameter sweep tool is self-contained and can easily be integrated within an outer-loop analysis or as desired by the user. 7) Ease of use: The tool is well documented and a simple sweep can be easily executed by following the online documentation in a few lines of code. We demonstrate the use of the parameter sweep tool on a simple water treatment system from the WaterTAP repository and show its parallel scaling performance on an Apple laptop and NREL's Eagle HPC. The parameter sweep tool is actively being used with models currently being developed within WaterTAP and we expect its use to grow beyond it to other IDAES and Pyomo models.

97 MATHEMATICS AND COMPUTING↗

EchemAMR (electro-chemical microsctructure scale models with adaptive meshing) [SWR-23-111]

A 3D microstructure resolving electrochemical transport and interfacial chemistry solver. Electrode microstructure plays an important role in determining the performance of an electrochemical system, e.g. lithium ion battery. EchemAMR is a microstructure scale model that solves the governing equations for ion transport, electrical current continuity, interfacial chemistry and structural mechanics. Complex microstructure geometries from imaging can be directly imported into EchemAMR. A volume fraction based description of the geometry on Cartesian grid with an immersed interface formulation enables simplified meshing and large-scale simulations with millions of degrees of freedom. EchemAMR has been tested against systems with analytic solutions for numerical convergence and highly resolved lithium ion battery microstructures. EchemAMR demonstrates excellent mass conversation and efficient scaling on heterogenous High-Performance Computing (HPC) with central and graphics processing units.

Sitaraman, Hariswaran↗

On the Representativity of Electrode Microstructure Parameters and Their Electrochemical Response for Lithium Ion Batteries

Lithium-ion battery electrochemical models require an accurate description of the electrodes microstructures to be predictive that can be achieved through nanoscale imaging. Such observations are however limited by their field of view (FOV), as they provide only a subset of the whole electrode volume that does not necessarily represent the whole electrode microstructure heterogeneity, and therefore can bias the microstructure analysis. A microstructure scale electrochemical model was used to investigate lithium plating onset, material non-uniform utilization, and in-plane heterogeneities for an NMC-graphite full cell. To evaluate the representativeness, and thus relevance, of these model predictions, a coupled representativity analysis has been performed on the microstructure parameters and, in a novel way, on the full cell electrochemical response. Electrode microstructure parameters representativeness has been first quantified using the representative volume element (RVE) methodology. The RVE major flaw is that ultimately it can only conclude if a FOV contains representative subvolumes of the FOV, but not if the FOV itself is representative of the electrode volume. Analysis can conclude negatively ('FOV is not representative'), but not positively ('FOV is representative'). One major contribution of this work was to quantify the convergence of the RVE size with the FOV, to actually investigate the FOV representativeness and thus partly remedy this intrinsic limitation. The analysis determined that performing a standard RVE calculation, without exploring its FOV convergence, is likely to strongly underestimate the actual RVE size. The new RVE methodology has been automated in the NREL open-source Microstructure Analysis Toolbox (MATBOX) and is available to the battery community. Representativeness of microstructure parameters is however only an intermediate step, as the end-results of an electrochemical model are performances predictions. Indeed, what is the practical consequence of a given deviation for a microstructure parameter? The microstructure parameter deviation propagations to the 3D microstructure scale electrochemical response have been then quantified for different charge rates. This defines a threshold for the microstructure parameters FOV for a desired maximum deviation of the electrochemical response. Such deviation propagation analysis is analogous to error propagation analysis and is necessary to determine the relevance of microstructure scale model predictions for macroscale predictions. Electrochemical model shows cell representative section areas are increasing with C-rate, due to higher in-plane heterogeneities, indicating larger FOVs are required specifically for fast charge modeling. Therefore, we introduced the novel concept of electrochemical RVE (eRVE) that is a function of the operating conditions (thus defined as a dynamic RVE), with an increasing dependence with the C-rate. Representativity analysis of the investigated cell determined a FOV of 144.4 x 54.4 m2 is large enough to establish a convergence on the representative section areas for low to intermediate C-rate (=2.5C), but not large enough to conclude for higher rates. This work aims to emphasize the importance of representativity analysis for LIB electrode microstructures, as it is required to estimate the error, and thus the relevance, of microstructure parameters intended to be used in macroscale models. The methodology and results can help researchers to select the relevant imaging and associated FOV required to provide accurate enough microstructure parameters.

ADVANCED PROPULSION SYSTEMS↗