Search NASA⌕ Search

Engineering topics

Ally, Moonis

Publications and source records attributed to Ally, Moonis.

Suitable low Global Warming Potential (GWP) refrigerants for two-speed Heat Pumps for residential applications based on speed Heat Pumps for residential applications based on simulated performance simulated performance

Cold climate Heat Pumps (CCHPs) using single-speed compressors in tandem have been successfully built and tested to reach its performance metrics with outdoor temperatures as low as -25°C. CCHPs must be designed to alleviate the problems of too high discharge temperatures, low suction pressure and high-pressure ratio at low ambient conditions and insufficient heating capacity relative to the heating capacity at 8.3°C. In this paper we recognize those concerns. Low-GWP refrigerants are screened based on the shape of their T-S saturation boundary. Simulations of the performance of low-GWP refrigerants (R32, R454B, R466A, and R452B) relative to R410A is done using the DOE/ORNL Heat Pump Design Model at the component level. Systemic inefficiency, the root cause of lost work, is addressed by component-level exergy analysis to refine design options. CCHPs using low-GWP refrigerants addresses issues of reducing energy consumption, lowering carbon footprint, and enabling environmentally sustainability. The CCHP was designed to meet a HSPF > 11.0 and SEER > 15.0 having adequate heat pump heating capacity down to -25°C. It is estimated that at least 2.6 million U.S homes using electric furnaces and heat pumps in cold or very old climates with an annual energy consumption of 0.17EJ would benefit by CCHPs.

Ally, Moonis↗

Residential Split Heat Pump Using Low GWP Refrigerants

Conventional refrigerants, e.g. R-410A have high global warming potentials (GWP) > 1800. They are being phased out to protect the environment. The candidates to replace R-410A include R-32, R-452B, R-454B and R-466A for heat pump applications. These candidates are intended for drop-in replacement, i.e. having minimum modifications on existing systems. The paper investigates the low GWP refrigerants drop-in application via system simulations using a well-regarded, hardware-based heat pump model. A baseline heat pump having all fin-and-tube heat exchangers and a two-speed compressor was used. Cross-comparisons were made under rated conditions of ambient temperatures, compressor speeds, indoor air flow rates, respectively for cooling and heating operations. The seasonal performance indices, i.e. SEER and HSPF are presented.

Shen, Bo↗

CRADA Number NFE-17-06866 with Active Energy Systems, Inc. (CRADA Final Report)

Cooperative Research and Development Agreement (CRADA) NFE-17-06866 between Oak Ridge National Laboratory (ORNL) and Active Energy Systems Inc. (AES) focused on studying and modeling a low cost, high efficiency energy storage technology. The successful development of low-cost, high-efficiency energy storage is a significant bottleneck in the implementation of intermittent renewable energy sources such as wind and solar. AES is a startup company developing a heat exchange technology to utilize a low-temperature phase change material (PCM). The work done under this CRADA explored this technology’s ability to augment a heat pump/heat engine device to convert electricity into thermal energy and vice versa, operating to complement the needs of the electric grid. Modeling, design and development of a prototype to prove the technology was successful, but current production economics and market demand make further exploration undesirable.

25 ENERGY STORAGE↗

Analysis of the P-T and T-S phase boundary in discriminating suitable low global warming potential and low flammability refrigerants

Although several alternative low GWP refrigerants including natural have been proposed, the HVAC industry consensus on how to deal with the attendant issues is still evolving. This paper provides invaluable qualitative and quantitative insight into the peculiar phase boundary shapes of refrigerants, essential for understanding their application, and in evaluating existing and future refrigerants. The methodology is firmly grounded in the thermodynamics of phase equilibria and the criteria of positive-definiteness, a direct consequence of the Second Law and the existence of intermolecular forces (IMF). The formal methodology is strikingly easy to implement in practice and explains clearly why certain refrigerants display re-entrant behavior while others do not, and how one can choose the proper refrigerant for a given refrigeration or heat pump application. The paper shows how an evidence-based selection can be made among the 40 refrigerants analyzed in this study.

Ally, Moonis↗

Analysis of the P-T and T-S phase boundary in discriminating suitable low global warming potential and low flammability refrigerants

Although several alternative low GWP refrigerants including natural have been proposed, the HVAC industry consensus on how to deal with the attendant issues is still evolving. This paper provides a qualitative and quantitative insight into the peculiar phase boundary shapes of refrigerants, essential for understanding their application, and in evaluating existing and future refrigerants. The methodology is firmly grounded in the thermodynamics of phase equilibria and the criteria of positive-definiteness, a direct consequence of the Second Law and the existence of intermolecular forces (IMF). The formal methodology is strikingly easy to implement in practice and explains clearly why certain refrigerants display “re-entrant” behavior while others do not. The paper shows how an evidence-based selection can be made among the 40 refrigerants analyzed in this study. Keywords: Low GWP, alternate refrigerants, heat pumps, VLE

Ally, Moonis↗

Novel Gas-Driven Fuel Cell HVAC and Dehumidification Prototype

Performance of a novel gas-driven, electricity-producing heating, ventilation, and air conditioning (HVAC) system with no vapor compression and no hydrofluorocarbon (HFC) refrigerant shall be discussed in the paper. The prototype was evaluated at ORNL under a Small Business Voucher (SBV) Cooperative Research and Development (CRADA) program. The target market is commercial buildings in the United States. The goal is to mitigate or eliminate grid-power for building air conditioning, coincident peak demand and associated spinning reserves, aiding in flattening of the “duck curve”. The technical goal is to transform the common packaged rooftop unit into a cost-effective distributed energy resource, opening a new range of small applications and broad markets for micro-combined cycle cooling, heating, and power with integral thermal energy storage. The test results indicate the prototype would be competitive with natural gas distributed power plants with average electrical production ranging from 45% to 60% natural gas to electricity conversion efficiency. The technology has a Primary Energy Savings Potential of 4.4 Quads, higher than any other air conditioning and heating technology.

Betts, Daniel↗

AMMONIA AS A NATURAL REFRIGERANT IN ELECTRICALLY AND THERMALLY DRIVEN ENGINES FOR HEAT PUMPS

Ammonia is an excellent refrigerant for use in absorption or in vapor compression heat pumps because of its favorable thermodynamic and heat transfer properties. We examine the choice of driving a heat pump with a thermally-driven (TD) engine as in the case of an absorption device, or with an electrically-driven (ED) engine, as in the case of a Rankine cycle heat pump. Which engine has a lower carbon footprint and has the least environmental impact is the quintessential issue discussed in this presentation. The question is examined through a comprehensive methodology of energy and exergy analysis which explains why the output of these two engines is so different, and what impact it makes for source energy consumption, and environmental stewardship. This work is a fundamental analysis which discusses the choices and consequences of ED versus TD heat pumps and its direct impact on the environment. Thermodynamic consistency is guaranteed by invoking the First and the Second Laws applied to various components and subsystems of the TD and ED heat pumps.

Ally, Moonis↗

Thermodynamics of Highly Concentrated Aqueous Electrolytes: Based on Boltzmann's eponymous equation

This sharply focused book invites the reader to explore the chemical thermodynamics of highly concentrated aqueous electrolytes from a different vantage point than traditional methods. The book's foundation is deeply rooted in Ludwig Boltzmann's eponymous equation. The pathway from micro to macro thermodynamics is explained heuristically, in a step-by-step approach. Concepts and mathematical formalism are explained in detail to captivate and maintain interest as the algebra twists and turns. Every significant result is derived in a lucid and piecemeal fashion. Application of the theory is exemplified with examples. It is amazing to realize that Boltamann's simple equation contains sufficient information from which such an elaborate theory can emerge. This book is suitable for undergraduate and graduate level classes in chemical engineering, chemistry, geochemistry, environmental sciences, and those studying aerosol particles in the troposphere. Students interested in understanding how thermodynamic theories may be developed would be inspired by the methodology. The author wishes that readers get as much excitement reading this book as he did writing it.

Ally, Moonis↗

AMMONIA AND PROPANE AS NATURAL REFRIGERANTS FOR HEAT PUMP APPLICATIONS

There has been an increasing interest in the use of natural refrigerants in order to minimize the environmental impact of air conditioning and refrigeration equipment. This article is focused on the performance characterization of two widely accepted natural refrigerants; ammonia and propane for heat pump applications. Different cycle configurations including basic vapor compression cycle, cycle with liquid-line/suction-line heat exchanger and a two-stage flash economizer cycle have been analyzed for the performance evaluation of ammonia and propane in comparison to R-134a and R410A. The ultimate objective is to evaluate the performance of a heat pump utilizing natural refrigerants perform in relatively warm and cold climate with minimum environmental impact.

Ally, Moonis↗

Commercial Absorption Heat Pump Water Heater: Beta Prototype Evaluation

The Beta version of the Commercial Absorption Heat Pump (CAHP) water heater was evaluated in the environmental chambers at Oak Ridge National Laboratory. Ambient air conditions ranged from 17 to 75 oF and inlet water temperatures ranged from 100 to 120oF in order to capture trends in performance. The unit was operated under full fire (100%) and partial fire (55%). The unit was found to perform at 90% of the project goal at the design conditions of 47oF ambient and 100oF water temperatures. The trends across the full range of environmental conditions were as expected for ambient air temperatures above 32oF. Below this temperature and for the full fire condition, frost accumulated on the evaporator coil. In future work a defrost strategy will be enabled, the unit will be thoroughly cleaned of an oil contamination and the rectifier will be reconfigured in order to meet the design goals and have a field test unit ready in early 2017.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ground Source Integrated Heat Pump (GS-IHP) Development

Between October 2008 and May 2013 ORNL and ClimateMaster, Inc. (CM) engaged in a Cooperative Research and Development Agreement (CRADA) to develop a groundsource integrated heat pump (GS-IHP) system for the US residential market. A initial prototype was designed and fabricated, lab-tested, and modeled in TRNSYS (SOLAR Energy Laboratory, et al, 2010) to predict annual performance relative to 1) a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (combination of air-source heat pump (ASHP) and resistance water heater) and 2) a state-of-the-art (SOA) two-capacity ground-source heat pump with desuperheater water heater (WH) option (GSHPwDS). Predicted total annual energy savings, while providing space conditioning and water heating for a 2600 ft 2 (242 m 2 ) house at 5 U.S. locations, ranged from 52 to 59%, averaging 55%, relative to the minimum efficiency suite. Predicted energy use for water heating was reduced 68 to 78% relative to resistance WH. Predicted total annual savings for the GSHPwDS relative to the same baseline averaged 22.6% with water heating energy use reduced by 10 to 30% from desuperheater contributions. The 1 st generation (or alpha) prototype design for the GS-IHP was finalized in 2010 and field test samples were fabricated for testing by CM and by ORNL. Two of the alpha units were installed in 3700 ft 2 (345 m 2 ) houses at the ZEBRAlliance site in Oak Ridge and field tested during 2011. Based on the steady-state performance demonstrated by the GS-IHPs it was projected that it would achieve >52% energy savings relative to the minimum efficiency suite at this specific site. A number of operational issues with the alpha units were identified indicating design changes needed to the system before market introduction could be accomplished. These were communicated to CM throughout the field test period. Based on the alpha unit test results and the diagnostic information coming from the field test experience, CM developed a 2 nd generation (or beta) prototype in 2012. Field test verification units were fabricated and installed at the ZEBRAlliance site in Oak Ridge in May 2012 and at several sites near CM headquarters in Oklahoma. Field testing of the units continued through February 2013. Annual performance analyses of the beta unit (prototype 2) with vertical well ground heat exchangers (GHX) in 5 U.S. locations predict annual energy savings of 57% to 61%, averaging 59% relative to the minimum efficiency suite and 38% to 56%, averaging 46% relative to the SOA GSHPwDS. Based on the steady-state performance demonstrated by the test units it was projected that the 2 nd generation units would achieve ~58% energy savings relative to the minimum efficiency suite at the Zebra Alliance site with horizontal GHX. A new product based on the beta unit design was announced by CM in 2012 – the Trilogy 40® Q-mode™ (http://cmdealernet.com/trilogy_40.html). The unit was formally introduced in a March 2012 press release (see Appendix A) and was available for order beginning in December 2012.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Making Homes Part of the Climate Solution: Policy Options To Promote Energy Efficiency

In the area of energy efficiency, advanced technologies combined with best practices appear to afford not only large, but also cost-effective options to conserve energy and reduce greenhouse gas emissions (McKinsey & Company, 2007). In practice, however, the realization of this potential has often proven difficult. Progress appears to require large numbers of individuals to act knowledgeably, and each individual must often act with enabling assistance from others. Even when consumer education is effective and social norms are supportive, the actions of individuals and businesses can be impeded by a broad range of barriers, many of which are non-technical in nature. Title XVI of the Energy Policy Act of 2005 included a mandate to examine barriers to progress and make recommendations in this regard. A detailed report on barriers as well as the National strategy for overcoming barriers met this requirement (Brown et al, 2008; CCCSTI, 2009). Following up on this mandate, the U.S. Climate Change Technology Program (CCTP) chose to focus next on the development of policy options to improve energy efficiency in residential buildings, with supporting analysis of pros and cons, informed in part by behavioral research. While this work is sponsored by CCTP, it has been undertaken in coordination with DOE's Building Technologies Program and Office of Electricity Delivery and Energy Reliability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗