Search NASA⌕ Search

Engineering topics

Almer, Jonathan D.

Publications and source records attributed to Almer, Jonathan D..

At least 19 records

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics (FY23 Project Report)

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques.

36 MATERIALS SCIENCE↗

Correlations of multiscale structural evolution and homogeneous flows in metallic glass ribbons

Studying the flow behavior is critical to understand the deformation mechanism of amorphous solids. However, detecting the basic flow events in amorphous solids is challenging. Here, by simultaneous SAXS/WAXS, elementary flow carriers in wound metallic glasses are identified from flow-induced structural heterogeneities with a radius of gyration of 2.5~3.5 nm. Their size increases and morphology changes from sphere-like to rod-like under flow. Moreover, the atomic structure exhibits an unusual change to a more disordered state during winding/annealing at the temperature of ~0.8 T g . This work provides an atomic-to-nanoscale description of the flow carriers of amorphous solids during deformation. Impact Statement The elementary flow carriers in metallic glasses have a radius of gyration of 2.5~3.5 nm. During flow, their size increases and morphology changes from sphere-like to rod-like.

36 MATERIALS SCIENCE↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics FY2022 Project Report

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques. In this first year of the project, all uranium oxide samples were synthesized and characterized using conventional analyses by the analytical chemistry laboratory. Conventional analysis methods included powder x-ray diffraction, scanning electron microscopy, impurity analysis via inductively coupled plasma mass spectrometry, and infrared spectroscopy. Impurity analysis shows a drop in boron content from UO 3 to the lowest U 3 O 8 calcination temperature, but otherwise no appreciable difference in any sample. Analysis of diffraction data shows a flip of peaks from UO 3 dominated for the 600 °C calcined sample to U 3 O 8 dominated at 700 °C and 800 °C. Analysis of scanning electron microscopy images shows that with increased calcination temperature the size distribution of particles seems to increase and broaden. Both of these last findings are in line with previously published data, though this work used significantly fewer particles to simply show similar trends instead of getting truly quantitative particle analysis. Infrared analysis similarly shows ingrowth of U 3 O 8 as calcination temperature is increased, along with depression of peaks associated with UO 3 and water. Samples were prepared for analysis at the Advanced Photon Source at beamline 1-ID. It is anticipated that analysis will occur in November of 2022. AI/ML techniques to de-noise data coming out of 1-ID during the analyses was also developed during this time using previously gathered data. Preliminary results using a self-supervision technique called Noise2Selfshow good de-noising of data. Once the uranium oxide samples are analyzed, real data will be used to test the de-noising and other AI/ML techniques that may be developed in the second year of the project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NNSA Advanced Photon Source Sector Opportunities Workshop (Workshop Summary)

An NNSA-Argonne National Laboratory workshop to define NNSA and external partner mission needs and opportunities at the Advanced Photon Source was held February 15-17, 2022. This workshop summary provides a fresh look at NNSA’s evolving mission needs, partner agency and university interests, x-ray photon characteristics, and technical requirements to meet those needs. The workshop was organized according to four breakout groups: Coupling dynamic drivers to a synchrotron, High explosives and chemical sciences, Process-structure-performance: X-ray experiments to understand materials behaviors, and Process-structure-performance: manufacturing and aging. This summary report describes the workshop outcomes, and the preliminary conceptual design for a dedicated Defense Materials Science Sector (DMSS) at the Advanced Photon Source.

36 MATERIALS SCIENCE↗

Unveiling the origins of work-hardening enhancement and mechanical instability in laser shock peened titanium

Laser shock-peening (LSP) produces complex gradients in microstructures and residual stresses, which enables fabrication of metallic engineering components with superior mechanical properties. In this work, we use non-destructive and spatially resolved high-energy X-ray diffraction (HE-XRD) to investigate the influences of LSP on microstructure, surface topography, and residual stress for high purity titanium plates. LSP is found to produce large compressive in-plane residual stresses near the peened surface which monotonically decay to zero about 2.5 mm below the surface. These properties were also tracked during in-situ tensile loading, allowing stress partitioning and work-hardening rates to be measured as a function of depth. The surface region is found to have the highest work-hardening rate and remain mechanically stable up to sample failure. In addition, a crystal rigid rotation along a transversal axis of about 27 & nbsp; was observed at large applied strain near the surface region, which is attributed to the formation of denser dispersed shear bands. Furthermore, a sudden drop in tensile stress was observed at a depth of similar to 160 mu m from the LSP surface, indicating the formation of a localized mechanical instability zone (LMIZ). The origin of this LMIZ could be attributed to the increase in shear stress induced by a load transfer from LSP surface due to the formation of denser dispersed shear bands. These observations indicate a localized transition in deformation behavior has occurred from dispersed shear banding to LMIZ and homogeneous deformation.

36 MATERIALS SCIENCE↗

Intact archeological human bones and age at death studied with transmission x–ray diffraction and small angle x–ray scattering

In this work, high-energy, wide-angle x-ray scattering (WAXS, x-ray diffraction) and small-angle x-ray scattering (SAXS) were used to study intact human second metacarpal bones (mc2) from two UK archeological sites. A novel method correcting for irregular mass distribution was applied in these transmission geometry experiments done at beamline 1-ID of the Advanced Photon Source. The authors asked whether there were age-at-death-related changes in carbonated apatite (cAp) lattice parameters and whether SAXS could detect collagen D-period peaks in the archeological mc2. For each of the two sites, Ancaster and Wharram Percy in England, six female mc2s were studied; for each site, two were from each of three age-at-death cohorts (young, 18-29 years; middle, 30-49 years; old >= 50 years) along with a modern control mc2. The Rietveld method was applied to the WAXS patterns to provide precise lattice parameter values. The cAp lattice parameters did not correlate with age-at-death estimated from dental wear. From WAXS and the 00.2 diffraction peak widths, four archeological mc2s possessed coherently scattering domain lengths (crystallite c-axis sizes) that matched that of the modern mc2; SAXS revealed the same four archeological mc2 had D-period peak intensities equivalent to that of the modern mc2. The other eight archeological mc2s had significantly larger crystallite sizes (than the modern mc2) and weak or absent D-period peaks, differences attributed to diagenetic changes. Based on these data, the authors suggest that WAXS 00.2 peak width and SAXS D-period peak intensity can be used with intact bones to select those likely to retain largely unaltered tissue nanostructure, which might be required for other analyses. Taken as a whole, the results suggest detecting age-related deterioration in nanostructural features may be difficult in bone showing significant bioerosion.

59 BASIC BIOLOGICAL SCIENCES↗

Chemo–mechanical properties of carbon fiber reinforced geopolymer interphase

Geopolymers, as a potentially environmentally friendly alternative to Portland cement, are increasingly attracting attention in the construction industry. Various methods have been applied for customizing the properties of geopolymers and improving their commercial viability. One of the promising methods for refining the properties of geopolymers such as their toughness is the use of short fibers. The effectiveness of a high-strength short fiber in the geopolymer matrix is largely dependent on the interfacial bonding between the fiber and its surrounding matrix. While the importance of this interfacial chemistry is highlighted in the literature, the characteristics of this bonding structure have not been fully understood. In this paper, we aim to investigate the bonding mechanism between the carbon fiber and metakaolin-based geopolymer matrix. For the first time, the existence and nature of the chemical bonding at the interfacial region (interphase) between carbon fiber and geopolymer matrix has been revealed. X-ray pair distribution function computed tomography (PDF-CT), field emission-scanning electron microscopy imaging, and nanoindentation techniques are employed to discern the chemo-mechanical properties of the interphase. PDF-CT results show the emergence of a new atom-atom correlation at the interfacial region (around 1.82 angstrom). This correlation is a characteristic of interfacial bonding between the fiber and its surrounding matrix, where the existence of chemical linkages (potentially Al-V-O-C) between fibers and the matrix contributes to the adhesion between the two constituents making up the composite. Due to such chemical bonding, the nanomechanical properties of the interfacial region fall between that of the carbon fiber and geopolymer. The combination of advanced techniques is proved useful for enhancing our understanding of the interfacial chemistry between fibers and the binding matrix. This level of knowledge facilitates the engineering of composite systems through the manipulation of their nanostructure.

36 MATERIALS SCIENCE↗

Deformation-enhanced hierarchical multiscale structure heterogeneity in a Pd-Si bulk metallic glass

Here, the multiscale structures in a Pd 82 Si 18 binary bulk metallic glass before and after deformation were studied using electron microscopies, high-energy synchrotron X-ray diffraction, and small-angle scattering techniques. The experimental results revealed an enhancement of hierarchical structure heterogeneities on multiple length scales after deformation. Hierarchical multiple shear bands of high number density were observed after bending, introducing complex but periodically distributed residual strain. Pair distribution function analysis revealed that the connectivity of the short-range clusters on the medium-range scale determines the packing density difference between the tension side and the compression side in the sample after bending. In-situ synchrotron X-ray diffraction study also revealed a transformation of connection modes among short-range clusters under uniaxial tension and compression, which is consistent with those of triaxial tension/compression parts upon bending in Pd 82 Si 18 glassy alloys. The nanoscale heterogeneities for metallic glasses after deformation observed by small-angle scattering and transmission electron microscopy may be attributed to the nanoscale amorphous phase separation and interacting multiple shear bands enhanced by plastic deformation. Our findings suggested that the enhancement of hierarchical heterogeneous structure on multiple length scales may explain the excellent plasticity of Pd-Si glassy alloys, deepening the understanding of structure-property relation during plastic deformation in metallic glasses.

36 MATERIALS SCIENCE↗

Precipitate Characterization in Model Al-Zn-Mg-(Cu) Alloys Using Small-Angle X-ray Scattering

Model 7000 series alloys with and without copper were fabricated into sheets to study precipitation hardening behavior under isothermal aging conditions. Samples of each alloy were subjected to 3 h annealing treatments at various temperatures to produce a range of precipitate size distributions. Hardness, electrical conductivity, and small-angle X-ray scattering (SAXS) were used to characterize the aging behavior of the two alloys. Precipitate size distributions were modeled from the scattering curves for each annealing condition using a maximum entropy method (MEM) and compared to select transmission electron microscopy (TEM) results. The measured average precipitate diameters from TEM were in good agreement with the average precipitate diameters determined from the scattering curves.

36 MATERIALS SCIENCE↗

High-Energy X-Ray Diffraction Microscopy in Materials Science

High-energy diffraction microscopy (HEDM) is an implementation of three-dimensional X-ray diffraction microscopy. HEDM yields maps of internal crystal orientation fields, strain states, grain shapes and locations as well as intragranular orientation distributions, and grain boundary character. Because it is nondestructive in hard materials, notably metals and ceramics, HEDM has been used to study responses of these materials to external fields including high temperature and mechanical loading. Currently available sources and detectors lead to a spatial resolution of ~1 μm and an orientation resolution of <0.1°. With the penetration characteristic of high energies ( E ≥ 50 keV), sample cross-section dimensions of ~1 mm can be studied in materials containing elements across much of the Periodic Table. This review describes hardware and software associated with HEDM as well as examples of applications. Overall, these applications include studies of grain growth, recrystallization, texture development, orientation gradients, deformation twinning, annealing twinning, plastic deformation, and additive manufacturing. We also describe relationships to other X-ray-based methods as well as prospects for further development.

36 MATERIALS SCIENCE↗

Strain rate sensitivity, microstructure variations, and stress-assisted β → α" phase transformation investigation on the mechanical behavior of dual-phase titanium alloys

In this study, the microstructures of three widely used dual-phase titanium alloys: Ti-6Al-4V, Ti-6Al-2Sn-4Zr-2Mo, and Ti-6Al-2Sn-4Zr-6Mo are characterized using backscatter electron imaging and the deformation behaviors in their individual α and β phases are investigated using in situ high-energy X-ray diffraction during uniaxial tension experiments. This is accompanied by calculation of the strain rate sensitivity (SRS) in these alloys, as a function of applied loading. The results of the calculated SRS and the mechanical response (in terms of lattice strains and hardening behaviors) are rationalized based on the local microstructure, composition, and texture of the alloy. A stress-induced β (BCC) to α" (orthorhombic) phase transformation is observed during the in-situ diffraction experiment, which permitted analysis of the lattice strain evolution during the phase transformation. Results from this study provide insights into the relationship between microstructure, composition, applied loading, and the deformation behavior, including effects on loading with time holds. Specifically, the results show that the microstructure, and not necessarily the chemical composition (Mo content), along with the applied loading have a dominant role in the observed SRS variation in titanium alloys. Further, the evolution of the α" (orthorhombic) phase is observed for the first time during deformation of an industrially relevant titanium alloy, Ti-6246.

36 MATERIALS SCIENCE↗

Investigating Grain Dynamics in Irradiated Materials with High-Energy X-rays (Final Report)

This report summarizes the research activities conducted at the Argonne National Laboratory (ANL) under the FY 2016 Consolidated Innovative Nuclear Research (CINR) Funding Opportunity Announcement (FOA) award CFA-16-10644: Investigating Grain Dynamics in Irradiated Materials with High-Energy X-rays. This project is a collaboration between the ANL and the Los Alamos National Laboratory (LANL). The research activities conducted at the LANL is summarized in the companion report, LA-UR-19-29312 titled “EVPSC Modeling of 316 Stainless Steel with and without Observed Phase Transformation.”

36 MATERIALS SCIENCE↗

Elucidating the nature of crystallization kinetics in Zr 46 Cu 46 Al 8 metallic glass through simultaneous WAXS/SAXS measurements

Simultaneous wide- and small-angle X-ray scattering (WAXS/SAXS) measurements were performed to investigate the low-temperature crystallization kinetics of Zr 46 Cu 46 Al 8 bulk metallic glass during isothermal annealing. Quantitative analysis of the WAXS intensity data indicated that the crystallization process was dominated by steady-state homogeneous nucleation and three-dimensional diffusion-controlled growth. This observation was corroborated by quantitative analysis of the SAXS data showing a saturation of the growth of nanoscale crystallites. Comparison of simultaneously measured WAXS and SAXS data showed evidence of composition fluctuation prior to crystallization, suggesting that the crystallization was facilitated by nanoscale phase separation which established regions of favorable compositions catalyzing crystallization. The temperature dependence of crystallization mechanisms and the resulting microstructures in metallic glass are discussed.

36 MATERIALS SCIENCE↗

Operando Quantification of (De)Lithiation Behavior of Silicon-Graphite Blended Electrodes for Lithium-Ion Batteries

Due to the high lithium capacity of silicon, the composite (blended) electrodes containing silicon (Si) and graphite (Gr) particles are attractive alternatives to the all-Gr electrodes used in conventional lithium-ion batteries. In this Communication, the lithiation and delithiation in the Si and Gr particles in a 15 wt% Si composite electrode is quantified for each component using energy dispersive X-ray diffraction. This quantification is important as the components cycle in different potential regimes, and interpretation of cycling behavior is complicated by the potential hysteresis displayed by Si. The lithiation begins with Li alloying with Si; lithiation of Gr occurs at later stages when the potential dips below 0.2 V (all potentials are given vs. Li/Li + ). In the 0.2 – 0.01 V range, the relative lithiation of Si and Gr is ~58% and 42%, respectively. During delithiation, Li + ion extraction occurs preferentially from Gr in the 0.01 – 0.23 V range and from Si in the 0.23 – 1.0 V range; that is, the delithiation current is carried sequentially, first by graphite and then by silicon. Furthermore, these trends can be used for rational selection of electrochemical cycling windows that limits volumetric expansion in Si particles, thereby extending cell life.

25 ENERGY STORAGE↗

In operando X-ray diffraction strain measurement in Ni 3 Sn 2 – Coated inverse opal nanoscaffold anodes for Li-ion batteries

Volume changes associated with the (de)lithiation of a nanostructured Ni 3 Sn 2 coated nickel inverse opal scaffold anode create mismatch stresses and strains between the Ni 3 Sn 2 anode material and its mechanically supporting Ni scaffold. By using in operando synchrotron x-ray diffraction measurements, elastic strains in the Ni scaffold are determined during cyclic (dis)charging of the Ni 3 Sn 2 anode. These strains are characterized using both the center position of the Ni diffraction peaks, to quantify the average strain, and the peak breadth, which describes the distribution of strain in the measured volume. Upon lithiation (half-cell discharging) or delithiation (half-cell charging), compressive strains and peak breadth linearly increase or decrease, respectively, with charge. The evolution of the average strains and peak breadths suggests that some irreversible plastic deformation and/or delamination occurs during cycling, which can result in capacity fade in the anode. The strain behavior associated with cycling of the Ni 3 Sn 2 anode is similar to that observed in recent studies on a Ni inverse-opal supported amorphous Si anode and demonstrates that the (de)lithiation-induced deformation and damage mechanisms are likely equivalent in both anodes, even though the magnitude of mismatch strain in the Ni 3 Sn 2 is lower due to the lower (de)lithiation-induced contraction/expansion.

25 ENERGY STORAGE↗

In situ synchrotron X-ray diffraction study of hydrides in Zircaloy-4 during thermomechanical cycling

The d-spacing evolution of both in-plane and out-of-plane hydrides has been studied using in situ synchrotron radiation X-ray diffraction during thermo-mechanical cycling of cold-worked stress-relieved Zircaloy-4. The structure of the hydride precipitates is such that the δ{111} d-spacing of the planes aligned with the hydride platelet face is greater than the d-spacing of the 111 planes aligned with the platelet edges. Upon heating from room temperature, the δ{111} planes aligned with hydride plate edges exhibit bi-linear thermally-induced expansion. In contrast, the d-spacing of the (111) plane aligned with the hydride plate face initially contracts upon heating. Furthermore, these experimental results can be understood in terms of a reversal of stress state associated with precipitating or dissolving hydride platelets within the α-zirconium matrix.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Concurrent determination of nanocrystal shape and amorphous phases in complex materials by diffraction scattering computed tomography

Advanced functional materials often contain multiple phases which are (nano)crystalline and/or amorphous. The spatial distribution of these phases and their properties, including nanocrystallite size and shape, often drives material function yet is difficult to obtain with current experimental techniques. This article describes the use of diffraction scattering computed tomography, which maps wide-angle scattering information onto sample space, to address this challenge. The wide-angle scattering signal contains information on both (nano)crystalline and amorphous phases. Rietveld refinement of reconstructed diffraction patterns is employed to determine anisotropic nanocrystal shapes. The background signal from refinements is used to identify contributing amorphous phases through multivariate curve resolution. Thus it is demonstrated that reciprocal space analysis in combination with diffraction scattering computed tomography is a very powerful tool for the complete analysis of complex multiphase materials such as energy devices.

Birkbak, Mie Elholm↗

i RadMat: A thermo-mechanical testing system for in situ high-energy X-ray characterization of radioactive specimens

Here, we present an in situ Rad iated Mat erials (iRadMat) experimental module designed to interface with a servo-hydraulic load frame for X-ray measurements at beamline 1-ID at the Advanced Photon Source. This new capability allows in situ studies of radioactive specimens subject to thermo-mechanical loading using a suite of high-energy X-ray scattering and imaging techniques. The iRadMat is a radiation-shielded vacuum heating system with the sample rotation-under-load capability. We describe the design features and performances of the iRadMat and present a dataset from a 300 °C uniaxial tensile test of a neutron-irradiated pure Fe specimen to demonstrate its capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗