Search NASA⌕ Search

Engineering topics

Amano, Ryoichi S.

Publications and source records attributed to Amano, Ryoichi S..

At least 19 records

Exploring the Effects of Guide Vane on Dimpled Cooling Channel of Gas Turbine Blade

Abstract The purpose of the current study is to find out the heat transfer and pressure drop phenomena of the cooling channel with dimples and guide vane and compare the results with the no guide vane dimpled cooling channel. The first leg of the cooling channel is 490 mm, and the second leg is 460 mm. The two legs relate to the 180 deg turn region. The guide vane was inserted at the bend region of the dimpled cooling channel. The study was conducted with two different guide vanes geometry at two different orientations, i.e., U-guide vane with protrusion and depression orientation and curve-guide vane with protrusion and depression orientations both experimentally and numerically. The numerical study was performed with the large eddy simulation method. The result shows that for both stationary and rotational motion, the U-guide vane with depression experiences the highest thermal performance. The friction factor is comparatively higher for curve-guide vane with protrusion under stationary motion. However, under rotation, the curve-protrusion guide encounters the highest friction factor, which is higher compared to the no guide vane cooling channel.

Energy & Fuels↗

Evaluation of Heat Transfer Enhancement on Rotational Gas Turbine Blade Internal Cooling Channel With Dimpled Surface

Abstract The present investigation represents the rotational effect on gas turbine blade internal cooling with a uniform heat flux of 2000 W/m2 at the bottom wall. The experiment was conducted with three different rpms, such as 300 rpm, 600 rpm, and 900 rpm, with Reynolds number (Re) ranging from 6000 to 50,000 with a two-pass cooling channel. The numerical investigation was conducted with the large eddy simulation (LES) technique to understand the rotational flow behavior of the cooling channel. Four distinct arrangements of dimpled cooling channel surfaces were considered with two different dimple shapes, i.e., partial spherical and leaf. It is found that the rotation effect, dimple arrangement, and design have significant influences on heat transfer. Results indicated that the partial spherical 1-row dimpled surface experienced the highest heat transfer coefficient and pressure drop. In contrast, the leaf-shaped dimpled cooling channel experienced the highest thermal efficiency.

Energy & Fuels↗

Experimental and Numerical Study on the Effect of Annular Combustor Design on Thermal Uniformity Jet in Crossflow

Abstract Non-uniformity of the exit flow temperature represents one of the significant damages to gas-turbine components, particularly turbine blades. This may occur in the course of gas-turbine operation. This paper aims to provide passive techniques by modifying the combustor design rather than changing the flow parameters to improve the thermal uniformity and turbine blades to reduce thermal stresses and increase turbine blades’ life span. An acceptable agreement between the numerical and experimental results has been achieved, and the agreement includes the velocity and temperature profile. Four different angles have been tested numerically and experimentally with a maximum error of 5% at two different Reynolds numbers. Designing the outer combustor surface with a 45-deg angle bend can give a more uniform temperature distribution of 37% higher than the basic design with only a 0.5% higher pressure drop.

Energy & Fuels↗

Effect of the J-Shaped Wind Turbine Airfoil Opening Ratio and Thickness on the Performance of Symmetrical Airfoils

Abstract In this work, the effect of the inner opening ratio on the J-shaped airfoils aerodynamic performance was studied and documented for symmetrical airfoils. Three different airfoil thicknesses were investigated: small (NACA0008), medium (NACA0015), and large (NACA0024). For each airfoil thickness, effects of three inner opening ratios were analyzed: one-third, one-half, and two-thirds. The performance of each opening ratio was compared with the performance of the solid airfoil “zero opening ratio” for different angles of attack between 5 deg and 20 deg. All designs were simulated using the computational fluid dynamics (CFD) technology against experimental results for solid NACA4412 airfoil in the University of Wisconsin-Milwaukee (UWM) wind tunnel facility and other published experimental data. It was found that large eddy simulation yields accurate solutions with a smaller number of mesh cells compared to the k–ω turbulence model but with much longer computational time. The lift-to-drag ratio for all studied airfoils has a maximum value for solid airfoils compared to those equipped with openings. For airfoils equipped with 00.00% opening ratio “solid,” NACA0015 airfoil has the maximum lift-to-drag ratio. Furthermore, it was found that NACA0008 equipped with a 33.33% opening ratio has the best performance of all studied J-shaped airfoils.

Energy & Fuels↗

Power Generation and Oxygen Transfer Analyses for Micro Hydro-Turbine Installed in Wastewater Treatment Aeration Tank

This study targets one of the major energy consumers in the U.S. It suggests a new mechanical system that can recover a portion of the energy in Wastewater Treatment Plants (WWTPs). The proposed system entails a hydro-turbine installed above the air diffuser in the aeration tank to extract the water-bubble current’s kinetic energy and converts it to electricity. Observing the optimum location of the turbine required multiple experiments where turbine height varies between 35% and 95% (water height percentages above the diffuser), while varying the airflow between 1.42 L/s (3 CFM) and 2.12 L/s (4.5 CFM) with a 0.24 L/s (0.5 CFM) increment. Additionally, three water heights of 38.1 cm (15*), 53.4 cm (21*), and 68.6 cm (27*) were considered to study the influence of the water height. It was noticed that the presence of the system has an adverse effect on the standard oxygen transfer efficiency (SOTE). Therefore, a small dual-blade propeller was installed right above the diffuser to directly mix the water in the bottom of the tank with the incoming air to enhance the SOTE. The results showed that the maximum reclaimed power was obtained where the hydro-turbine is installed at 65–80% above the diffuser. A reduction of up to 7.32% in SOTE was observed when the setup was placed inside the tank compared to the tank alone. The addition of the dual-blade propeller showed an increase in SOTE of 7.27% with a power loss of 6.21%, ensuring the aeration process was at its standards.

Energy & Fuels↗

Optimizing Power Reclamation of Micro Hydro Turbines in WWTPs Aeration Basins

Abstract This study investigates the optimum operating conditions and design configurations that can optimize the power reclaimed by small hydro turbines derived by the rising water-bubble current. The rising current is generated by the compressed air introduced by the diffusers at the bottom of aeration basins of Wastewater Treatment Plants (WWTPs). While optimizing the power production, the standard oxygen transfer efficiency (SOTE) is monitored since it is a significant parameter that cannot be sacrificed in the operation of WWTPs. Using one set of turbine blades, it was found out that the highest velocity is obtained in the upper half of the water column (70% - 80%). In contrast, the lowest velocities were obtained just above the air diffuser and at the water surface. Testing started with using a single turbine (ST) to determine the location of the optimum power reclaimed at each tested airflow (1.18, 1.42, 1.65, and 1.89 L/s). Then using double turbine (DT) and triple turbine (TT) to compare their performance to the ST’s maximum power increased power reclamation. The maximum percentage of increase in power reclamation for DT is 19.59%, while it is 20.24% in the case of TT. At a commonly used airflow in WWTPs (1.42 L/s), the optimum configurations of DTs and TTs were selected to investigate the effect of having the proposed setup on the SOTE. For membrane diffusers, DTs and TTs limited the dispersion of the air bubbles in the tank, therefore, reducing the SOTE (8.3% for DT and 3.7% for the TT). The ceramic and sharp-nub diffusers were also tested versus rubber membrane ones to determine the effect of using the ceramic and sharp-nub diffusers on the power reclamation and SOTE. Ceramic diffusers neither achieve higher power reclamation than the membrane nor increases the SOTE. In contrast, sharp-nub diffusers increase the SOTE for all configurations compared to membranes, but this came into account of power reclamation, where sharp-nub diffusers cause a DT and a TT to produce less power than ST does.

Energy & Fuels↗

Experimental Study on Flow Behavior and Heat Transfer Enhancement With Distinct Dimpled Gas Turbine Blade Internal Cooling Channel

Abstract The study presents the investigation on heat transfer distribution along a gas turbine blade internal cooling channel. Six different cases were considered in this study, using the smooth surface channel as a baseline. Three different dimples depth-to-diameter ratios with 0.1, 0.25, and 0.50 were considered. Different combinations of partial spherical and leaf dimples were also studied with the Reynolds numbers of 6,000, 20,000, 30,000, 40,000, and 50,000. In addition to the experimental investigation, the numerical study was conducted using a large eddy simulation (LES) to validate the data. It was found that the highest depth-to-diameter ratio showed the highest heat transfer rate. However, the deepest dimpled channel shows the highest pressure drop, which affects the overall thermal performance of the cooling channel. The results showed that the leaf dimpled surface is the best cooling channel based on the highest Reynolds number's heat transfer enhancement and friction factor. However, at the lowest Reynolds number, partial spherical dimples with a 0.25 depth-to-diameter ratio showed the highest thermal performance.

Energy & Fuels↗

Experimental and Large Eddy Simulation Study for Visualizing Complex Flow Phenomena of Gas Turbine Internal Blade Cooling Channel With No Bend

Abstract In this study, the internal cooling channel was investigated without any bend. Smooth surfaces and dimpled surfaces were investigated using the different combinations of connecting circular and rectangular holes. The computations were performed using the large eddy simulation (LES) model for Reynolds (Re) numbers from 10,000 to 50,000. A total of six different connecting holes were investigated with a smooth and dimpled surface. A partial spherical dimple with two circular holes showed the highest heat transfer, but it has a higher pressure loss penalty. Even though the leaf dimpled surface with the rectangluar holes indicated a little low heat transfer, it represents the highest efficiency at higher Reynolds numbers because of the low-pressure drops.

Energy & Fuels↗

Energy, Exergy, and Emission Analysis on Industrial Air Compressors

Abstract Air compressors, a key fluid power technology, play an essential role in industrial plants and office buildings, hospitals, and other types of facilities. The efficient use of the air compressor is crucial. By controlling unnecessary inefficiencies, high energy consumption can be reduced. This study aims to provide energy and exergy analysis on air compressors for different industries. Detailed case studies were also analyzed. The case study focuses on the energy and exergy analyses of the compressed air system of foundry industries. The results indicate that applying the six improvement recommendations yields significant amounts of energy and cost savings and significant improvements in the system's overall performance. The payback periods for different recommendations are economically feasible and worthwhile to use. The suggested improvement methods can provide cost savings with a low payback period.

Energy & Fuels↗

Performance of Hybrid Renewable Energy Power System for a Residential Building

Using fossil fuels as the primary way to generate electricity causes a significant effect on the environment. In 2019, more than 64% of the electricity in the United States of America was generated using fossil-fuel resources, while renewable energy (RE) resources contributed to only 17% of the U.S. electricity generation for the same year. Additionally, due to the complex terrain distribution of many states in the U.S., a massive opportunity of utilizing RE resources in rural and remote areas can reduce the cost of electrical grid installation for such areas. In this study, a typical residential building with an average energy utilization of 30.25 kWh/day with a demand peak of 5.34 kW was considered a case study in each state to optimize a hybrid RE system and find the best alternative electrical grid system. This study presents the best configuration between solar and wind energy with different types of energy storage. It was discovered the photovoltaic (PV) solar panels—diesel generators with battery best services in all states. The daily radiation and diesel prices substantially affect the levelized cost of energy (COE) values in each state.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Economic, Exergy, and Environmental Analyses of the Energy Assessments for U.S. Industries

Abstract This paper highlights the expected versus actual outcomes of 152 energy assessments that were performed between 2011 and 2020. The 1317 energy-assessment recommendations (ARs) are grouped into eight categories. This study adopted four measures per each category of recommendations: annual electricity savings, annual gas savings, annual cost savings, and annual CO2 emission reduction. The first part of the analysis compares the expected to the actually implemented values of the measures applied to each recommendation’s category. It was found that the percentages of the actual to the expected electricity, gas, and cost savings are 26.6%, 11.4%, and 17.1%, respectively, while the percentage of the actual to the expected CO2 reduction is 22%. Moreover, the second part of the analysis presents each category's implementation rate and the reasons for rejecting the unimplemented ARs. Cash flow and expensive initial investment resulted in rejecting 25% of ARs. Furthermore, the study proposes techniques and strategies to increase ARs’ implementation rate and improve private energy services companies’ implementation rate. Finally, exergy analysis is added to show the improvement that energy assessment achieves regarding exergy and exergy efficiencies of different industrial applications.

Energy & Fuels↗

Net Zero Energy Model for Wastewater Treatment Plants

The primary objective of this study is to achieve net-zero energy (NZE) wastewater treatment plants (WWTPs) by utilizing energy efficiency opportunities (EEO), combined heat and power (CHP) systems, and other renewable energy (RE) sources, e.g., solar, water, and wind powers. Herein, this study discusses an innovative energy solution for WWTPs in the United States, and one of the WWTPs with a flow capacity of 1.5 million gallons per day (MGD) was selected as a case study. An optimization tool, Hybrid Optimization of Multiple Energy Resources (HOMER) software, is used in this study to find the best energy system configuration to run the system. An energy audit for one WWTP was conducted in early 2020 and the report is used to do this study. The proposed EEOs were able to reduce WWTP energy consumption by about 11%. The excess anaerobic digester gas was utilized in a CHP system to cover about 42% of the facility’s consumption. Also, 3% of the utility energy consumption can be claimed by microturbines in the aeration tanks. Another two renewable energy systems, solar photovoltaic (PV) with 29% and water turbines with 15%, contribute to covering 100% of the WWTP energy consumption and achieving an NZE WWTP.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of Energy Savings and CO2 Emission Reduction Contribution for Industrial Facilities in USA

Abstract Energy audits can identify energy consumptions, energy costs of the facility and evolve to develop measures to maximize efficiency, optimize supply energy, and eliminate waste. This paper investigates the potential energy savings at 20 different industrial sectors with 152 assessments for various facilities in Wisconsin, USA. On average, eight energy recommendations were suggested and applied in each facility. This paper provides a detailed guideline for each industry in terms of eight different energy categories: heating, ventilation, and air conditioning (HVAC) systems, heat recovery systems, electrical demand management, and utility bills, motors, compressors, waste management, and productivity enhancement, lighting, besides building envelope. In total, the energy savings were as follows: 98 million kWh in the shape of electricity, 561 billion British thermal units (BTUs) gas savings, 44 million gallons water savings, and 2-million-pound solid waste savings. Based on these savings, a 100-thousand-ton reduction in carbon dioxide emissions was obtained.

Energy & Fuels↗

The Power Reclamation of Utilizing Micro-Hydro Turbines in the Aeration Basins of Wastewater Treatment Plants

Upgrading the aeration basin technology can improve the oxygen transfer efficiency (OTE), while keeping the energy consumption at its minimum level. Therefore, this paper introduces a new idea of installing micro-propeller turbines in the aeration basin of a wastewater treatment plant (WWTP) to extract power from the high-velocity location in the water column. This extracted power can be used to operate a mixer at the top of the membrane to induce the mixing in that region, which will drive the less oxygenated wastewater into the water column. The rest of the extracted power will rotate microturbine rotors for electric power generation. By applying the proposed microturbines to the 13 audited facilities, it was demonstrated to achieve a gross annual energy-savings of 3,836.9 MWh, a gross annual cost-saving of $260,497, and total CO 2 emissions that would be reduced by 2,714 metric tons/year. Generally, the addition of the proposed microturbines can save up to 15.7% of the annual plant electricity consumption (1.3–12.8% of the plant annual electricity bills).

13 HYDRO ENERGY↗

Study of Energy Saving Analysis for Different Industries

This study analyzes the energy consumption and saving performance in the industries in the U.S.A. All energy assessments implemented were for facilities whose annual energy consumptions were less than 9,000,000 kWh (small- and medium-sized industries) that belong to the manufacturing industries with Standard Industrial Classification (SIC) codes ranging from 2000 to 3999 in addition to SIC codes starting with 49. In this study, assessments are classified based on the SIC codes with recommendations analysis for each classification to get a better idea of what recommendations were suggested in each major industrial sector, knowing that 68 assessments were made, and their SIC ranged from 14 to 49. In addition, this study could be considered as a guide for energy engineers and other personnel involved in the energy assessment process. The information investigated can give a better prediction for composing better energy-demanding industries and minimizing energy consumption. More than 61 energy assessments were conducted for manufacturing facilities and analyzing the data gathered and processed. Through the research, the Fabricated Metal industry achieved the highest average kWh savings and cost savings within the industries studied in this study. According to the average gigajoule (GJ) savings, the fabricated metal industry ranked second within the studied industries. Conversely, Food and Kindred Products achieved the highest GJ energy savings within the studied industries. Overall, lighting, motors, compressors, and heating, ventilation, and air conditioning (HVAC) were the most contributing industries in a total of 547 recommendations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Water Energy Resource Innovation on the Cavitation Characteristics

The main purpose of this study is to numerically correlate the amount of generated vapor over a hydrofoil to the lift and drag coefficients acting on it. As such, cavitation characteristics were investigated of a hydrofoil in the cavitating, sub-cavitating, and non-cavitating flows for different angles of attacks (AoA) with the high upstream flow velocity. The hydrofoil was tested in a square water tunnel with water entering the tunnel at various velocities for each AoA ranges from 9.1 m/s to 12.2 m/s. It was found that lift and drag forces acting on the hydrofoil follow the trend of the experimental data quite closely. While the cavitation can be identified by a unique number (averaged vapor volume fraction), the work done created an inverse correlation between this number and the cavitation number at the same angle of attack. The lift force declines with the increase in the vapor content on the hydrofoil surface, meanwhile the drag force peaks at certain vapor volume fraction, and then, a huge reduction occurs with the considerable decrease in the corresponding cavitation number. A fourth-order correlation generated between the lift to drag (L/D) and the cavitation number (σ). It was found the lift-to-drag ratio decreases by the formation of the cavitation over the hydrofoil, thus causing a drop in the efficiency of the turbomachines.

42 ENGINEERING↗

Co-Pyrolysis of Chicken and Cow Manure

Conventional pyrolysis is a relatively simple way for biochar production; however, a single biomass feedstock approach is not promising for the development of multiple properties of biochar used in various applications. Here, this study provides a detailed comparison in terms of pyrolysis kinetics between the cow manure and chicken manure, in addition to the co-pyrolysis by mixing the two livestock at different ratios. Eight different heating rates were tested, 5–40 °C/min with 5 °C/min step, on both livestock using the nitrogen as a gas agent with a flowrate of 50 ml/min. The initial results show that for the slow heating rates, 5 °C/min, the thermal degradation of the cow manure is different compared to that obtained from chicken manure. For the cow manure, the first peak, associated with hemicellulose decomposition, is higher than the second peak, associated with cellulose decomposition, which is the other way around for chicken manure. At 5 °C /min, the hemicellulose decomposition took place at 250 °C and 300 °C for the chicken manure and cow manure, respectively. The cellulose decomposition was started at 300 °C for chicken manure and 470 °C for cow manure. The lowest heat rate was selected for the co-pyrolysis case study to allow a quasi-equilibrium state to avoid measurement errors and heat transfer limitation in terms of thermal lag. Co-pyrolysis is studied with different blend ratios between the chicken and cow manure, where the 40% cow manure shows a positive result in terms of keeping an exothermic reaction over the co-pyrolysis process.

09 BIOMASS FUELS↗

Analytical Study to Use the Excess Digester Gas of Wastewater Treatment Plants

This study presents an analytical method that can be used to enhance the power production rate and the energy-saving at wastewater treatment plants. The digester used at wastewater treatment plants produces digester gas by anaerobic digestion, with which biofuel production can be achieved. Biofuels can be used to meet some of the energy requirements of the wastewater treatment facility through combined heat and power (CHP) gas engines (cogeneration). Using micro gas turbine (MGT), a CHP technology can be introduced in wastewater treatment plants (WWTPs). The combination of MGTs and absorption chillers is a promising technology as it produces electricity, heating, and cooling simultaneously. The study demonstrated how the waste heat of MGTs could be used to drive absorption chillers. In this analytical study, a detailed technical and economic analysis is provided on the trigeneration system, i.e., the integration of MGTs and absorption chillers driven by waste digester gas of the wastewater treatment plants. It can meet the heating and cooling demands of the plants, which promote the reduction of utility costs. The technology presented is also useful for other thermal energy users.

09 BIOMASS FUELS↗