Search NASA⌕ Search

Engineering topics

Ames, F

Publications and source records attributed to Ames, F.

Recent developments of the ion sources at Tri University Meson Factory/Isotope Separator and ACcelerator Facility

This paper describes the recent progresses concerning the on-line ion source at the Tri University Meson Factory/Isotope Separator and ACcelerator (TRIUMF/ISAC) Radioactive Ion-Beam Facility; description of the new design of the surface-ion-source for improved stability of the beam intensity, description of the transport path to the east target station at ISAC, description of the new brazing techniques that solved recurrent problems with water leaks on the target/ion source assembly in the vacuum system, finally, recent developments concerning the Forced Electron Beam Induced Arc Discharge (FEBIAD) ion source are reported. In particular, a study on the effect of the plasma chamber volume on the ionization efficiency was completed.

43 PARTICLE ACCELERATORS↗

First direct measurement of the {sup 23}Mg(p,gamma){sup 24}Al reaction

The lowest-energy resonance in the {sup 23}Mg(p,gamma){sup 24}Al reaction, which is dominant at classical nova temperatures, has been measured directly for the first time using the DRAGON recoil spectrometer. The experiment used a radioactive {sup 23}Mg beam (mixed within a significantly stronger {sup 23}Na beam) of peak intensity 5x10{sup 7} s{sup -1}, at the ISAC facility at TRIUMF. We extract values of E{sub R}=485.7{sub -1.8}{sup +1.3} keV and omegagamma=38{sub -15}{sup +21} meV from our data (all values in the center-of-mass frame unless otherwise stated). In addition, the experiment prompted a recalculation of the Q value for this reaction based on a revision of the {sup 24}Al mass. The effect on the uncertainties in the quantities of ejected {sup 22}Na and {sup 26}Al from oxygen-neon classical novae is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Charge state breeding for the acceleration of radioactive ions at TRIUMF

A 14.5 GHz electron cyclotron resonance ion source (PHOENIX from Pantechnik) has been set up at the Isotope Separation and ACceleration (ISAC) facility at TRIUMF for the charge state breeding of radioactive ions. After extensive testing and optimization on a test bench it has been moved on-line and put into operation. During a first test in 2008 a beam of {sup 80}Rb{sup 14+} was successfully created from {sup 80}Rb{sup 1+} and accelerated by the ISAC postaccelerator. Further tests with different stable and radioactive isotopes from the ISAC on-line sources and from a test source with stable Cs have been carried out. Until now an efficiency of 1.4% for {sup 124}Cs{sup 20+} has been obtained.

43 PARTICLE ACCELERATORS↗

First Penning-Trap Mass Measurement of the Exotic Halo Nucleus {sup 11}Li

In this Letter, we report a new mass for {sup 11}Li using the trapping experiment TITAN at TRIUMF's ISAC facility. This is by far the shortest-lived nuclide, t{sub 1/2}=8.8 ms, for which a mass measurement has ever been performed with a Penning trap. Combined with our mass measurements of {sup 8,9}Li we derive a new two-neutron separation energy of 369.15(65) keV: a factor of 7 more precise than the best previous value. This new value is a critical ingredient for the determination of the halo charge radius from isotope-shift measurements. We also report results from state-of-the-art atomic-physics calculations using the new mass and extract a new charge radius for {sup 11}Li. This result is a remarkable confluence of nuclear and atomic physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct Mass Measurement of the Four-Neutron Halo Nuclide {sup 8}He

A high-precision Penning trap mass measurement of the exotic {sup 8}He nuclide (T{sub 1/2}=119 ms) has been carried out resulting in a reduction of the uncertainty of the halo binding energy by over an order of magnitude. The new mass, determined with a relative uncertainty of 9.2x10{sup -8} ({delta}m=690 eV) is 13 keV less bound than the previously accepted value. The mass measurement is of great relevance for the recent charge-radius measurement of {sup 8}He [P. Mueller et al., Phys. Rev. Lett. 99, 252501 (2007).]. The {sup 8}He mass is the first result from the newly-commissioned Penning trap: TITAN (TRIUMF's Ion Trap for Atomic and Nuclear science) at the ISAC (Isotope Separator and Accelerator) radioactive beam facility at TRIUMF.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

0{sub gs}{sup +}{yields}2{sub 1}{sup +} Transition Strengths in {sup 106}Sn and {sup 108}Sn

The reduced transition probabilities, B(E2;0{sub gs}{sup +}{yields}2{sub 1}{sup +}), have been measured in the radioactive isotopes {sup 108,106}Sn using subbarrier Coulomb excitation at the REX-ISOLDE facility at CERN. Deexcitation {gamma} rays were detected by the highly segmented MINIBALL Ge-detector array. The results, B(E2;0{sub gs}{sup +}{yields}2{sub 1}{sup +})=0.222(19)e{sup 2}b{sup 2} for {sup 108}Sn and B(E2;0{sub gs}{sup +}{yields}2{sub 1}{sup +})=0.195(39)e{sup 2}b{sup 2} for {sup 106}Sn were determined relative to a stable {sup 58}Ni target. The resulting B(E2) values are {approx}30% larger than shell-model predictions and deviate from the generalized seniority model. This experimental result may point towards a weakening of the N=Z=50 shell closure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coulomb Excitation of the N = 50 nucleus {sup 80}Zn

Neutron rich Zinc isotopes, including the N = 50 nucleus {sup 80}Zn, were produced and post-accelerated at the Radioactive Ion Beam (RIB) facility REX-ISOLDE (CERN). Low-energy Coulomb excitation was induced on these isotopes after post-acceleration, yielding B(E2) strengths to the first excited 2{sup +} states. For the first time, an excited state in {sup 80}Zn was observed and the 2{sub 1}{sup +} state in {sup 78}Zn was established. The measured B(E2,2{sub 1}{sup +}{yields}0{sub 1}{sup +}) values are compared to two sets of large scale shell model calculations. Both calculations reproduce the observed B(E2) systematics for the full Zinc isotopic chain. The results for N = 50 isotones indicate a good N = 50 shell closure and a strong Z = 28 proton core polarization. The new results serve as benchmarks to establish theoretical models, predicting the nuclear properties of the doubly magic nucleus {sup 78}Ni.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sub-Barrier Coulomb Excitation of {sup 106,108,110}Sn

The reduced transition probabilities between the first excited 2{sup +} state and the 0{sup +} ground state, B(E2;0{sup +}{yields}2{sup +}), have been measured in {sup 106,108,110}Sn using sub-barrier Coulomb excitation in inverse kinematics at REX-ISOLDE. The results are, B(E2;0{sup +}{yields}2{sup +}) = 0.220(22), 0.226(17), and 0.228(32)e{sup 2}b{sup 2}, for {sup 110}Sn, {sup 108}Sn, and {sup 106}Sn, respectively. The results for {sup 106,108}Sn are preliminary. De-excitation {gamma}-rays were detected by the MINIBALL Ge-array. The B(E2) reveals detailed information about the nuclear wave function. A shell model prediction based on an effective CD-Bonn interaction in the {nu}(0g{sub 7/2},2s,1d,0h{sub 11/2}) model space using e{sub eff}{sup {nu}} = 1.0 e follows the experimental values for the neutron rich Sn isotopes, but fails to reproduce the results presented here.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quadrupole collectivity of neutron-rich nuclei around {sup 132}Sn

We report on the 'safe' Coulomb excitation of neutron-rich Cd, Xe, and Ba isotopes in the vicinity of the doubly-magic nucleus {sup 132}Sn. The radioactive nuclei have been produced by ISOLDE at CERN and postaccelerated by the REX-ISOLDE facility. The {gamma}-decay of excited states has been detected by the MINIBALL array. The presented preliminary results for the B(E2) values are consistent with expectations from phenomenological systematics and will be compared with theoretical calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The ECRIS charge state breeding project at TRIUMF

The performance of charge state breeding with an electron cyclotron resonance (ECR) ion source intended to increase the charge state of online produced radioactive ions at the ISAC facility at TRIUMF has been investigated. A 14 GHz PHOENIX from PANTECHNIK has been setup on a test bench. Singly charged ions have been produced with several ion sources typical for the on-line operation and were injected into the charge breeder. The main purpose of the tests has been the optimization of the efficiency for the charge breeding into the desired charge state. Maximum efficiencies reached so far with the standard one step deceleration of the ions in front of the plasma are up to about 6% for noble gas ions and about 3.5% for alkalines. As ion optics simulations show, the acceptance can be increased by a two step deceleration. In order to meet the velocity acceptance of the accelerator at different A/q values a similar two gap acceleration system for the highly charged ions has been installed to allow the source to run at different voltages. For the further beam transport to the accelerator, cross sections for charge exchange of the highly charged ions with the residual gas have been determined.

43 PARTICLE ACCELERATORS↗

Off-line ion source terminal for ISAC at TRIUMF

The off-line ion source (OLIS) terminal consists of a microwave cusp ion source, either a surface ion source or a hybrid surface-arc discharge ion source and an electrostatic switch that allows selecting any one of the sources without mechanical intervention. These sources provide variety of beams to ISAC experiments, for commissioning the accelerators, for setting up the radioactive experiments, and for tuning the beam lines. The microwave ion source has been operational since 1995 and provides singly and doubly charged beams from various stable isotopes for many ISAC experiments at high and low energy areas. Originally its prime goal was to provide beams from gaseous elements, but later two ovens and a sputtering system were added in order to provide beams from liquids and from solids. The surface ion source installed in 2002 can provide low energy spread beams from alkali and semialkali elements. It also has three separate ovens and an ionizer. Therefore, it can provide three different temperature regions simultaneously to provide different beams to ISAC. It is mainly used for laser spectroscopy experiments and other experiments, which require a finite beam quality. A hybrid surface-arc discharge ion source was also developed and installed in order to meet specific demands from experiments. This source terminal is now automated for start up and for mass selection. It is capable of providing stable beams for months without maintenance and it is also capable of providing negative ion beams if required. To date, over 40 different isotopes including many rear isotopes were delivered to various experiments from the OLIS source terminal. Performances of the ion sources and some of the results are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗