Search NASA⌕ Search

Engineering topics

Amichi, Lynda

Publications and source records attributed to Amichi, Lynda.

A Three–Dimensional Nanoscale View of Electrocatalyst Degradation in Hydrogen Fuel Cells

The loss of platinum (Pt) electrochemically active surface area (ECSA) is a critical degradation mode that often becomes a limiting factor for heavy-duty proton exchange membrane fuel cell vehicles. High surface area carbon supports have been shown to improve Pt dispersion and limit detrimental ionomer-electrocatalyst interactions due to their large interior pore volume. Here, in this work, using automated scanning transmission electron tomography, the degradation of nanoparticles located on the interior versus exterior surfaces of the carbon support is compared following a catalyst-specific accelerated stress test (AST) of 90,000 voltage cycles between 0.6 V to 0.95 V. The results reveal a notable increase in median particle size for both interior and exterior Pt catalyst particles, with a slightly higher increase in particle size distribution and loss of specific surface area for the particles located on the exterior carbon surface. The fraction of Pt nanoparticles that reside within the interior of the carbon support also increased following the AST test, accompanied by evidence of an increase in average carbon mesopore size. Here, the results shed light on the degradation mechanisms affecting electrochemical properties and the enhanced particle accessibility at lower relative humidity.

08 HYDROGEN↗

A scalable membrane electrode assembly architecture for efficient electrochemical conversion of CO2 to formic acid

Abstract The electrochemical reduction of carbon dioxide to formic acid is a promising pathway to improve CO 2 utilization and has potential applications as a hydrogen storage medium. In this work, a zero-gap membrane electrode assembly architecture is developed for the direct electrochemical synthesis of formic acid from carbon dioxide. The key technological advancement is a perforated cation exchange membrane, which, when utilized in a forward bias bipolar membrane configuration, allows formic acid generated at the membrane interface to exit through the anode flow field at concentrations up to 0.25 M. Having no additional interlayer components between the anode and cathode this concept is positioned to leverage currently available materials and stack designs ubiquitous in fuel cell and H 2 electrolysis, enabling a more rapid transition to scale and commercialization. The perforated cation exchange membrane configuration can achieve >75% Faradaic efficiency to formic acid at <2 V and 300 mA/cm 2 in a 25 cm 2 cell. More critically, a 55-hour stability test at 200 mA/cm 2 shows stable Faradaic efficiency and cell voltage. Technoeconomic analysis is utilized to illustrate a path towards achieving cost parity with current formic acid production methods.

08 HYDROGEN↗

Investigation of Nanoparticle Degradation in Hydrogen Fuel Cell Systems through Automated Electron Microscopy

Proton exchange membrane fuel cells (PEMFC) are promising devices for the deployment of hydrogen-powered heavy-duty vehicles, providing a higher efficiency for similar driving range and fueling time than the existing ones. However, PEMFCs still encounter durability challenges mainly due to catalyst degradation in the cathode. Mitigating these performance losses requires a better understanding of the degradation mechanisms under heavy-duty accelerated stress tests (ASTs) [1]. Scanning transmission electron microscopy (STEM) combined with energy dispersive X-ray spectroscopy (EDS) are key tools for the analysis of Pt and PtCo nanoparticle size, spatial distribution and composition [2]. Electron tomography is also used to determine the rate and type of degradation of catalyst nanoparticles as a function of their position on the carbon support. In this work, automated data acquisition software, paired with a custom Python code, have been used to study the effect of different accelerated stress tests (ASTs) on nanoparticle coarsening [2]. Figure 1 shows high-angle annular dark-field (HAADF)-STEM images and EDS maps comparing the cathodes of membrane electrode assemblies (MEAs) following an electrocatalyst AST performed under H2/N2 with that of the heavy-duty AST performed under H2/air. We will discuss how AST conditions affect considerably the spatial distribution of the nanoparticles across the electrode between the membrane and microporous layer. Although the median particle size increased more in the MEA aged under the heavy-duty AST, as determined using a high-throughput image analysis, the quantitative EDS measurements demonstrate that the electrocatalyst AST resulted in more Pt and Co dissolution from the cathode, which is another important indicator of electrocatalyst degradation. We will further present the impact of the relative humidity (% RH) on the degradation mechanisms demonstrated using the same approach. Electron tomography has been used to distinguish the Pt nanoparticles residing on the carbon support surface (exterior) from those within the pore structure (interior) in order to determine the relative stability of interior and exterior nanoparticles. As shown in Figure 2, we will compare the Pt catalyst particle size at the beginning of test (BOT) and end of test (EOT), and discuss the importance of automating the electron tomography workflow, i.e. acquisition, reconstruction, and visualization, to increase sampling and determine the standard deviation of these measurement. The outlook for utilizing low-dose cryo-tomography for limiting damage to the catalyst, support, and especially proton-conducting ionomer will also be discussed [3].

Amichi, Lynda↗