Nonlinear Detector Response of Aqua MODIS Land Imaging Bands

The detectors in Aqua MODIS reflective solar bands (RSB) are calibrated assuming a linear relationship between the observed top-of-atmosphere radiance and the instrument output response. Any non-linear behavior in the system response can contribute to errors in NASA’s Level 1B MODIS reflectance and radiance products, which are used in a wide variety of Earth science applications. While most RSB detectors continue to have very linear behavior even after more than 18 years of operation, we present evidence that the detectors in Aqua MODIS bands 1 (645 nm) and 2 (858 nm) have deviations from gain linearity that change over the mission by up to 3%. We show a clear divergence between gain measurements made with the on-board solar diffuser (SD) at two different radiance levels, achieved by collecting data both with and without an attenuation screen. Radiance trends from lunar calibrations and typical desert and ocean scenes are also compared. We present a simple method to characterize the response non-linearity using a quadratic function by combining the results of the two sets of SD calibrations. Applying this quadratic calibration algorithm to the desert and lunar data results in improved agreement in their long-term radiance trends. A clear understanding of the magnitude of the gain non-linearity could be useful to help improve the quality of numerous MODIS science products, including the land imaging applications that rely heavily on these bands.

MODIS↗

Improvements of On-orbit Characterization of Terra MODIS Short-wave Infrared Spectral Bands Out-of-Band Responses

The short-wave infrared (SWIR) bands (5-7, 26) of Terra MODIS, which are co-located with the mid-wav e infrared (MWIR) bands (20-25) on the short and mid-wave infrared (SMIR) Focal Plane Assembly (FPA),have a known issue related to 5.3 μm out-of-band (OOB) thermal leak and electronic crosstalk that was identified prelaunch. As a result, a crosstalk correction algorithm was designed and implemented in the MODIS Level 1B (L1B) calibration. Shortly after the Terra launch, extensive efforts were under taken to help characterize and mitigate the impact due to the OOB response and crosstalk on the SWIR on-orbit calibration and, consequently, the associated L1Bdata products. In addition, special night time day mode (NTDM) operations have been regularly scheduled to derive the crosstalk correction coefficients. Since MODIS does not have a spectral band centered at 5.3 μm, its band 28 (7.325 μm) was chosen as the surrogate sending band to simulate the OOB radiances at 5.3 μm. This was largely based on the measurements from the MODIS Airborne Simulator (MAS) spectrometer field campaigns in the early months after the Terra launch. In the case of Aqua MODIS, the magnitude of the SWIR crosstalk was much smaller and band 25 (4.52 μm) was found to be more effective as the sending band for the crosstalk correction. In recent years, the Terra MODIS photovoltaic (PV) long-wave infrared (LWIR) bands (27-30)electronic crosstalk has increased considerably, especially after the spacecraft safe-mode event occurred in February2016. This accentuated degradation in the PV LWIR performance has also impacted the performance of the SWIR crosstalk correction and thus its calibration and data quality. In this paper, we examine the use of band 25 as the sending band for the Terra MODIS SWIR crosstalk correction and compare its performance with that based on band 28 as the sending band. Results indicate an improvement of on-orbit gain stability for the SWIR calibration and reduced detector to detector and sub-frame to sub-frame striping in the calibrated L1B imagery, especially during the period when the PV LWIR electronic crosstalk has become more severe. This approach has been implemented in the forward production of Terra MODIS Collection 6 and Collection 6.1,starting from July 2019, and is planned to be used for the future reprocessing of MODIS L1B and to help improve the mission-long reflectance calibration and trending stability of the SWIR bands.

MODIS, Terra, Aqua, MODIS, SWIR, calibration, out-↗

Performance of NOAA-20 VIIRS Solar Diffuser and Solar Diffuser Stability Monitor

Visible Infrared Imaging Radiometer Suite (VIIRS) radiometrically calibrates its reflective solar bands (RSBs) primarily through a sunlit onboard solar diffuser (SD). The sunlit SD provides a known radiance under the condition that the absolute product of the SD screen transmittance and the bidirectional reflectance distribution function (BRDF) along the SD-to-telescope direction is accurately known. The BRDF changes due to solar exposure. The change, referred to as the H-factor, is monitored by the onboard SD stability monitor (SDSM). The accuracy of the retrieved H-factor propagates to the retrieved F-factor which corrects the scene spectral radiance. High accuracy of the retrieved H-factor relies on high accuracies in the SDSM screen relative effective transmittance and the relative product of the SD screen effective transmittance and the BRDF at the mission start, and a high SDSM detector signal-to-noise ratio (SNR). This article briefly reviews the algorithms used for the NOAA-20 (N20) VIIRS RSB on-orbit radiometric calibration. Additionally, we show the performance of the N20 VIIRS SDSM, giving the SDSM detector SNRs and the SDSM detector gain temporal changes. We develop a model for the SNRs. The model shows that the decreased SNRs in time are due to the detector gain decreases. We also show the N20 VIIRS SD on-orbit performance, measured by the retrieved H-factor and the estimated standard deviation of its error. The H-factor for the telescope view is obtained from the H-factor for the SDSM view, multiplied by an H-factor angular dependence term. We use an innovative method to determine the angular dependence, using the dependence obtained for the Suomi National Polar-orbiting Partnership (SNPP) VIIRS.

VIIRS↗

The MODIS RSB calibration and look-up-table delivery process for Collection 6 and 6.1

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on-board the Aqua and Terra space-craft have provided valuable science data for the last 18 and 20 years, respectively. Each instrument is equipped with 36 spectral bands, 20 of which are reflective solar bands (RSBs). These bands cover a wavelength range of 0.4 – 2.2μm and are calibrated on-orbit using several on-board calibrators (OBCs), such as a solar diffuser (SD)and a solar diffuser stability monitor (SDSM), along with regularly-scheduled lunar observations through the space view (SV) port. The gain (1/m1) and response-verses-scan angle (RVS) are updated on a near-monthly basis and act as the primary look-up-tables (LUTs) for the RSB calibration. A set of separate uncertainty LUTs for each of the RSBs are also delivered regularly and incorporated into the Level 1B (L1B) product to generate a pixel-level Uncertainty Index (UI). In addition to the gain, RVS and uncertainty, there are several other LUTs associated with the reflective bands that are either updated less frequently or remain static. The accuracy of both the forward-predicted and historical RSB LUTs, which are derived by the MODIS Characterization Sup-port Team (MCST), is important in maintaining the quality and accuracy of the L1B and science products.To ensure a timely and accurate LUT update, MCST has established a comprehensive set of procedures. This paper provides an overview of the calibration process, along with the current LUT delivery process for the RSB sin Collection 6 (C6) and Collection 6.1 (C6.1). Improvements to be implemented in future collections are also discussed.

MODIS↗

MODIS and VIIRS Calibration and Characterization in Support of Producing Long-Term High-Quality Data Products

Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) have successfully operated since their launches in 1999 and 2002, respectively, and generated various data products to support the Earth remote sensing disciplines and users worldwide for their research activities and applications, including studies of the Earth system, and its changes over time and geographic regions. The MODIS data have also significantly contributed to the continuity of multi-decadal satellite data records and led to major advances in the Earth remote sensing field. The long-term data records from MODIS observations have been and will continue to be extended by the Visible Infrared Imaging Radiometer Suite (VIIRS) instruments, currently operated aboard the Suomi-National Polar-Orbiting Partnership (NPP) and NOAA-20 satellites. The data quality of satellite instruments strongly depends on their calibration accuracy and stability. In order to help scientists and users gain a better understanding of MODIS and VIIRS data quality, this paper provides an overview of their on-orbit calibration methodologies, approaches, and results derived from instrument on-board calibrators and lunar observations, as well as select Earth view targets. What is also discussed is the calibration consistency between MODIS and VIIRS and its potential impact on producing multi-sensor long-term data records. As illustrated, the overall performance of both MODIS and VIIRS continues to meet their design requirements.

MODIS↗

MODIS Detector Differences Using Deep Convective Clouds and Desert Targets

An accurate on-orbit characterization of the Moderate Resolution Imaging Spectroradiometer (MODIS) sensors onboard the Terra and Aqua satellites is essential to satisfy the requirements from the scientific community for high-quality operational and research products. In this study, NASA’s C6.1 L1B data are utilized to assess the stability of the calibrated top of atmosphere reflectance retrieved from individual detectors within a spectral band over deep convective clouds (DCCs) and desert sites. The results from these invariant Earth targets show detector-to-detector (D2D) differences in the L1B reflectance products for select MODIS reflective solar bands. For Aqua MODIS, the D2D differences have no significant change over time for the bands studied. However, the D2D differences exhibit an increase in magnitude over time for Terra MODIS bands 1, 3-7, and 26, which can induce noticeable striping and higher uncertainties in the downstream data products. The D2D stability assessment results over DCCs are consistent with those observed over desert sites. In addition, the view-angle dependence of the D2D differences is investigated by separating the frames along scan into five zones. The D2D assessment is performed for each of the five zones, and the results will further benefit any improvements in the calibration of a detector-dependent response versus scan angle that can be considered for future MODIS Level 1B Collections.

MODIS↗

MODIS Reflective Solar Bands Lunar Calibration Update and Improvements

The MODerate resolution Imaging Spectroradiometer (MODIS) instruments on-board the Terra and Aqua spacecrafts were launched on December 18, 1999 and May 4, 2002, respectively. Each instrument has been scheduled to view the Moon through its Space View (SV) port approximately once per month in order to monitor the long-term radiometric stability of their reflective solar bands (RSB). The lunar calibration has played a key role in tracking the change in the response versus scan angle (RVS) of the instrument’s scan mirror, which is an essential part of the RSB calibration. The lunar irradiance observed by MODIS depends on the view geometry and it is crucial to remove the geometric effects in order to derive accurate RSB calibration coefficients. With a scheduled roll maneuver, the lunar phase angles are kept in a narrow range of 1° for each MODIS instrument such that the impact of these geometric effects is minimized. Nevertheless, it remains a challenge to completely remove the impact of geometric effects in the calibration coefficients derived from the lunar observations, considering the high expectations for the accuracy and quality of the results. In the current MODIS lunar calibration, the geometric effects on the lunar irradiance are corrected by the RObotic Lunar Observatory (ROLO) model. The overall relative uncertainty of the ROLO model for the MODIS calibration has been assessed to be about 1% in the selected lunar phase angle range of 1°. It could be as large as 4% beyond this small phase angle range, especially for the shortest wavelengths. This uncertainty induces noticeable oscillations in the calibration coefficients derived from the lunar observations. We developed a simple lunar model, which is based on MODIS lunar measurements, derived from scheduled lunar observations, as well as those obtained from intrusion of the Moon in the SV, referred to as unscheduled lunar observations, in the time period from 2005 to 2012. Here, the scheduled lunar observations for the entire mission are reprocessed with the new lunar model applied to correct the view geometry effects for each MODIS instrument. New calibration coefficients for the RSBs are calculated. We show that oscillations and noise in the derived lunar calibration coefficients are significantly reduced for both MODIS instruments.

Terra↗

Analysis of the on-orbit Response-Versus-Scan-angle for the MODIS SWIR Bands Derived from Lunar Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) on board the Terra and Aqua platforms is a multi-spectral, whiskbroom scanning radiometer with 36 spectral bands covering wavelengths from 0:4 - 14:2 μm. Among these bands, the 20 reflective solar bands (RSB, 0:4 - 2:1 μm) use an on-board solar difuser (SD) and SD stability monitor (SDSM) to track the detector gain changes on orbit. In addition to this, lunar and Earth-view (EV) observations are used in order to characterize the scan-mirror response versus scan angle (RVS), which improves the Earth-view retrieval over the full width of each scan. For the short-wave infrared bands (SWIR, 1:2 - 2:1 μm), the prelaunch RVS has been used for both Aqua and Terra MODIS throughout each mission. While these bands are not expected to have a significant change in the RVS on-orbit, issues such as electronic crosstalk and an out-of-band optical leak have prevented the use of the Moon for deriving the on-orbit RVS for validation. However, recent improvements to the MODIS lunar calibration for the SWIR bands allow us to mitigate the electronic crosstalk impact and derive the RVS for the SWIR bands. In this work, we will assess the impact of this newly derived RVS on the EV data compared to MODIS Collection 6.1. By comparing to EV data obtained from pseudo-invariant calibration sites at different angles-of-incidence on the scan mirror, we can assess the effectiveness of the newly derived RVS from the Moon. We find that while the change in the RVS on-orbit for the SWIR bands is relatively small, applying a correction to the RVS based on the Moon and SD data can provide an improvement for some bands.

MODIS↗

N20 VIIRS RSB Calibration Algorithms and Results: Collection 2.0

The NOAA-20 (N20) satellite, previously the Joint Polar Satellite System-1 satellite, was launched on November 18, 2017. One of the five major scientific instruments aboard the satellite is the Visible Infrared Imaging Radiometer Suite (VIIRS). VIIRS scans the Earth’s surface in 22 spectral bands, 14 of which are the reflective solar bands (RSBs) with band center wavelengths from 0.412 to 2.25μm. VIIRS regularly performs on-orbit radiometric calibration of its RSBs, primarily through the observations of the onboard solar diffuser (SD). The on-orbit change of the SD’s bidirectional reflectance distribution function, known as the H-factor, is determined by the onboard SD stability monitor (SDSM). Since the H-factor exhibits angular dependence, obtaining the H-factor along the SD to the telescope direction is a challenge for the NOAA-20 VIIRS. Recently, Collection 2.0 of the NASA Land Science Investigator-led Processing Systems (SIPS) products were released. As a part of this reprocessing effort, we made two major improvements in the N20 VIIRS RSB radiometric calibration. One is the improved SD and SDSM attenuation screen transmittance functions, obtained by using calibration data collected during both the yaw maneuver and a small portion of regular orbits, resulting in a higher quality H-factor for the SDSM view. Another is the use of the H-factor for the telescope view, derived from the H-factor for the SDSM view, by using the results for the SNPP VIIRS. In June 2019, we delivered a set of mission-long N20 VIIRS Collection 2.0 RSB radiometric calibration look-up-tables. These tables have been employed by the NASA Land SIPS group to reprocess the entire time series of the NOAA-20 VIIRS products. In this paper, we discuss the Collection 2.0 NOAA-20 VIIRS RSB calibration algorithms and results.

N20 VIIRS↗

Terra MODIS: 20 years of on-orbit calibration and performance

Since its launch in December 1999, Terra Moderate Resolution Imaging Spectroradiometer (MODIS) has successfully operated for more than 20 years, with its observations generating a broad range of science data products that have greatly enabled the remote sensing community and users worldwide in their studies of many key geophysical parameters of the Earth’s systems. MODIS collects data in 36 spectral bands, covering wavelengths from 0.41 to 14.4 μm, which are calibrated by a set of onboard calibrators (OBCs). Also contributing to the sensor’s mission-long on-orbit calibration and characterization are near-monthly scheduled lunar observations and multiple time series of the sensor’s responses over select ground targets at a variety of scan angles. To a large extent, the quality of MODIS data products relies strongly on the dedicated efforts to operate and calibrate the instrument, to derive and update calibration parameters, and to develop and implement new calibration strategies and algorithms in response to on-orbit changes of the sensor’s characteristics and its OBC functions. We provide an overview of the Terra MODIS on-orbit operation and calibration activities over the last 20 years, including changes made to extend and preserve the instrument and OBC functions and their operation strategies. It also illustrates the sensor’s on-orbit performance with results derived from its OBC, lunar observations, and select ground targets and discusses major changes in sensor characteristics and corrections applied to the L1B algorithms as well as calibration lookup table updates. To date, the Terra MODIS instrument and its OBCs continue to operate and function normally. Except for those identified prelaunch, most spectral bands and detectors continue to meet their specified calibration requirements. Also discussed in our paper are lessons learned from Terra MODIS operation and calibration, as well as future efforts to further extend and maintain the quality of its long-term data records.

Terra↗

Effects of Out-of-Band and Time-Varying Relative Spectral Response on the Calibration of MODIS Reflective Solar Bands

Calibration of the on-orbit gain changes of the narrow bandwidth reflective solar bands (RSB) of Terra and Aqua MODIS is usually based on the band center wavelength. The relative spectral response (RSR) of each band is assumed to be constant on orbit and the time dependence of an overall gain factor is calculated. Any on-orbit changes to the RSR of the MODIS bands will introduce some error into the calibration and may also have an impact on the Earth scene radiance retrieval. We consider two different ways to track how the RSR of the MODIS RSB may be changing on orbit, and the effects that these changes will have on the calibration. First, we study the broadband degradation of the MODIS scan mirror and how it may be changing the effective out-of-band response of the RSB. Second, we examine in-band RSR measurements from the spectro-radiometric calibration assembly (SRCA) carried on-board both MODIS instruments. We find that RSR changes have a relatively small effect on the radiance calibrated using the on-board solar diffuser, generally less than 0.5% for all RSB at any time in the missions, though the effect may be slightly larger for some scan angles. The impact of RSR changes on the Earth scene radiance retrieval is highly dependent on the spectral properties of the scene and could be significantly larger. The bands showing the largest impacts are Terra bands 1, 4, 8, 9, 17, and 19 and Aqua bands 8 and 9.

MODIS↗

Stability Assessment of OCO-2 Radiometric Calibration Using Aqua MODIS as a Reference

With three imaging grating spectrometers, the Orbiting Carbon Observatory-2 (OCO-2)measures high spectral resolution spectra (λ/∆λ≈19,000) of reflected solar radiation within the molecular oxygen (O2) A-band at 0.765 μm and two carbon dioxide (CO2) bands at 1.61 and 2.06 μm. OCO-2 uses onboard lamps with a reflective diffuser, solar observations through a transmissive diffuser, lunar measurements, and surface targets for radiometric calibration and validation. Separating calibrator aging from instrument degradation poses a challenge to OCO-2. Here we present a methodology for trending the OCO-2 Build 8R radiometric calibration using OCO-2 nadir observations over eight desert sites and nearly simultaneous observations from Moderate Resolution Imaging Spectroradiometer (MODIS) with sensor viewing zenith angles of 15 ± 0.5°. For the O2 A-band, this methodology is able to quantify a drift of−0.8 ± 0.1% per year and capture a small error in correcting the aging of the solar calibrator. For the other two OCO-2 bands, no measurable changes were seen, indicating less than 0.1% and less than 0.3% per year drift in the radiometric calibration of Band 2 and Band 3, respectively.

radiometric calibration↗

Cross-Calibration of Terra and Aqua MODIS Using RadCalNet

The twin MODIS instruments onboard the Terra and Aqua spacecraft have been successfully operating for nearly two decades and providing complementary observations of the Earth’s land, ocean, and atmosphere. Although the two MODIS instruments view the entire Earth’s surface once every 2-3 days, simultaneous views between them are limited due to their varying orbits. Therefore, the intercomparison between these two instruments has been previously performed using a transfer instrument (such as AVHRR) or using lunar measurements normalized using a common model such as the USGS ROLO. In recent years RadCalNet, a CEOS initiative, has provided SI-traceable Top-of-Atmosphere (TOA) reflectances from a coordinated network of instrumented land-based sites. RadCalNet facilitates a unique mechanism to perform cross-calibration of instruments by minimizing the uncertainties associated with overpass time differences. In this work, the near-simultaneous TOA reflectance measurements from the Railroad Valley, US (RVUS) are used as a transfer to compare the on-orbit observations for the Terra and Aqua MODIS RSB. Near-nadir overpasses from January 2013 to January 2019 are processed and matched up with near-simultaneous RadCalNet measurements. Results show that the VIS/NIR bands agree to within 2% and the SWIR bands agree to within 5%. Also, discussed in this work are the future efforts that will be undertaken to expand this comparison to include other instruments, other sites, and both nadir- and off-nadir views after compensation for BRDF effects.

Amit Angal↗

Assessment of SNPP VIIRS RSB detector-to-detector differences using deep convective clouds and deserts

An accurate on-orbit characterization of the Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-orbiting Partnership satellite is essential to satisfy the requirements from NOAA, NASA, and the general research community for high-quality operational and research products. NASA’s Land Science Investigator-led Processing System (LSIPS) sensor data records (SDRs) are utilized to assess the stability of the calibrated top of atmosphere reflectance over the deep convective clouds (DCCs) and over the Libya-4desert site. The results from DCCs and desert show detector-to-detector (D2D) reflectance differences in the VIIRS reflective solar bands, 10 moderate-resolution bands (M-bands, M1to M5, M7 to M11), and three imagery resolution bands (I-bands, I1-I3). More importantly, the D2D differences exhibit an increase in magnitude over time for bands M1 to M5 and I1to I2, which induces noticeable striping and higher uncertainties in the downstream data products. The largest D2D difference is observed in bands M1 and M2, with magnitudes greater than1.8% in trends among the 16 detectors and standard deviations less than 0.12% over time. TheD2D stability assessment results over DCCs are consistent with those observed over the Libya-4desert site. To improve the quality of the calibrated SDR reflectance data, NASA’s VIIRS characterization support team has improved the calibration algorithm to incorporate corrections based on these DCC measurements to mitigate the striping (detector differences) observed in the current version of the SDR. These improvements are planned to be included in the next mission reprocessing of the LSIPS land products.

SNPP VIIRS↗

Response Versus Scan-Angle Assessment of MODIS Reflective Solar Bands in Collection 6.1 Calibration

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments onboard the Aqua and Terra satellites have been operated for nearly two decades, producing high-quality earth observation data sets suitable for a broad range of scientific studies regarding the earth’s land, ocean, and atmospheric processes. The high radiometric accuracy of MODIS reflective solar band (RSB) calibration has also served as benchmark measurements for on-orbit cross-calibration studies. As the two MODIS instruments have operated well beyond their design lifespan of six years, the measurements from the onboard calibrators alone become inadequate to characterize the sensor’s response at all scan angles, as evinced by long-term drifts observed at certain scan positions of the Aqua-MODIS 0.64- and 0.86-μm bands in Collection 6 (C6) data set. The latest MODIS Level 1B C6.1 data set incorporates earth-view response trending from invariant desert sites as supplemental inputs to characterize the scan-angle calibration dependencies for all RSB. This article presents a deep convective cloud (DCC)-based calibration approach for an independent evaluation of the MODIS RSB response versus scan-angle (RVS) performance in C6.1. The long-term calibration stability and RVS differences in C6.1 have been significantly improved for Aqua-MODIS RSB. The observed RVS differences of more than 2% in Aqua-MODIS C6 bands 1 and 2 have been reduced to within 1% in C6.1. Some RSBs of Terra-MODIS have suffered temporal drifts up to ~2% and calibration shifts up to 3%, particularly around 2016 when the Terra satellite entered into safe mode. The DCC approach has been found very effective in tracking the on-orbit RVS changes over time.

Clouds and the Earth’s Radiant Energy System (CERE↗

Orbital Path and Spacecraft Attitude Correction for the MODIS Lunar Spatial Characterization

For the Moderate Resolution Imaging Spectroradiometer(MODIS) on the Terra and Aqua platforms, regularlyscheduled lunar observations using spacecraft roll maneuvershave been used extensively for sensor characterization. Whilethe primary purpose of these observations is for radiometriccalibration of the reflective solar bands, they have also beenleveraged for a number of other sensor performance assessments,such as the band-to-band (BBR) and detector-to-detector (DDR)spatial registration. The spatial registration calculations arecomplicated by the fact that the Moon does not move in astraight path across the sensor field-of-view (FOV). This path isdetermined by the relative orbital motion between the spacecraftand the Moon and the instrument attitude error that resultsfrom the roll maneuver. In this work, we develop a correctionfor the MODIS lunar spatial characterization measurements bycalculating the predicted path of the Moon across the sensor FOVusing spacecraft and lunar ephemeris data to model the relativeorbital motion between the spacecraft and the Moon along withspacecraft attitude error data acquired during the roll maneuver.The difference between measured and predicted positions of theMoon in the MODIS FOV can be used to calculate the BBRand DDR results. Since the predicted path across the FOV willbe the same for each band, the BBR results will be minimallyaffected. However, we will show that the along-scan spread inthe DDR can be significantly reduced, which results in a muchgreater consistency throughout the full mission for both Aquaand Terra MODIS.

Truman Wilson↗

Improvements in the on-orbit response versus scan-angle characterization for the MODIS ocean color bands

On-orbit characterization of the response versus scan-angle (RVS) is one of the most challenging aspects of the reflective solar band (RSB) calibration for the MODIS instruments onboard the Terra and Aqua spacecraft. The degradation of the solar diffuser, together with the lack of onboard calibrators (OBCs) to cover additional scan angles, other than the one for the lunar observations, has resulted in the use of Earth view responses from the pseudo-invariant desert sites to track the on-orbit RVS changes. This approach has been implemented in Collection 6 (C6) and C6.1 for bands 1-4, 8 and 9 of both instruments and also band 10 of Terra MODIS. As the missions continue to operate over a decade beyond their designed life and the instrument optics continue to degrade, it is expected that the OBC based RVS currently applied to other bands, specifically the high-gain ocean bands, will be inadequate to maintain the long-term calibration stability. An interband calibration approach is formulated and implemented in this paper. The proposed approach relies on the use of a spectrally matching stable reference band to evaluate the long-term calibration stability of the high-gain ocean bands that typically saturate while viewing the selected calibration deserts. Results from this approach indicate a noticeable drift for Terra MODIS bands 11 and 12 whereas the Aqua bands continue to show excellent temporal stability. These results are consistent with the corrections derived by the NASA Ocean Biology Processing Group (OBPG) and are expected to have minimum impacts on the downstream science products.

MODIS↗

Lunar calibration and performance assessments of the NOAA-20 VIIRS reflective solar bands

The Moon has played a vital role in the radiometric stability monitoring of NASAs Earth Observing System sensors, such as MODIS on the Terra and Aqua spacecrafts. The lunar calibration methodologies developed for the two MODIS instruments were later extended to apply to the VIIRS instrument on the Suomi-NPP spacecraft. The follow-on VIIRS instrument on the NOAA-20 (N20) spacecraft (previously JPSS-1) has been successfully operating since its launch in November 2017. Fifteen VIIRS spectral bands are in the reflective solar spectral region, covering wavelengths from 0.4 to 2.3 μm. Similar to the previous MODIS and VIIRS instruments, the N20 VIIRS views the Moon via a spacecraft roll maneuver on a near-monthly basis at a confined phase angle range (-51.5° to -50.5°) to facilitate radiometric stability monitoring with reduced uncertainties. In this paper, we briefly present the lunar calibration methodology and also report the derived instrument gain parameters from the regularly scheduled lunar calibrations. The USGS Robotic Lunar Observatory (ROLO) model is used to provide the predicted lunar irradiance for each lunar measurement to account for the variation in the observation geometry. The spatial characterization algorithms using the Moon, previously developed for MODIS and SNPP VIIRS, have also been extended to N20 VIIRS to track its on-orbit band-to-band registration (BBR).

VIIRS↗