Search NASASearch

Engineering topics

Anderson, Gregory

Publications and source records attributed to Anderson, Gregory.

Effect of simethicone on the bactericidal efficacy of a high-level disinfectant

Introduction.Simethicone is an over-the-counter product that is frequently used by clinicians during endoscopic procedures to reduce foaming and improve visualization. Published studies have found simethicone residue on endoscopes after cleaning and disinfecting the devices as per the manufacturer’s instructions. Some literature suggests that simethicone residue may reduce disinfection efficacy and increase the risk of patient infections. Gap Statement.However, there appears to be a lack of direct evidence in the literature to either disprove this or correlate simethicone presence with an increased microbial risk. Aim: Research was conducted to evaluate thein vitroimpact of simethicone on disinfection efficacy. Methodology.Bacteria were grown in a microtitre plate assay in the presence of a range of simethicone concentrations and then treated with a disinfectant. Bacterial growth was assessed by spotting each microtitre well onto an agar plate. Results.The results demonstrated that, under the conditions tested, simethicone did not reduce the efficacy of Cidex ortho-phthalaldehyde disinfectant, which demonstrated at least a 6-log unit reduction in bacterial viability. Additional experiments showed that direct exposure to 66 mg ml −1 of simethicone reduced bacterial viability. Conclusion.These results indicate that simethicone may not reduce the bactericidal efficacy of disinfectant during reprocessing, under certain conditions.

Microbiology

Multiaxial Temperature- and Time-Dependent Failure Model

A temperature- and time-dependent mathematical model predicts the conditions for failure of a material subjected to multiaxial stress. The model was initially applied to a filled epoxy below its glass-transition temperature, and is expected to be applicable to other materials, at least below their glass-transition temperatures. The model is justified simply by the fact that it closely approximates the experimentally observed failure behavior of this material: The multiaxiality of the model has been confirmed (see figure) and the model has been shown to be applicable at temperatures from -20 to 115 F (-29 to 46 C) and to predict tensile failures of constant-load and constant-load-rate specimens with failure times ranging from minutes to months..

Richardson, David

An observational study of MHD wave-induced density fluctuations upstream of the earth's bow shock

An investigation of plasma density fluctations upstream of the earth's bow shock and their association with MHD waves is reported. The normalized density fluctuation was 14 percent on a day when the plasma beta was less than unity and the waves were circularly polarized and of relatively low amplitude, and 17 percent on a day when the plasma beta was in excess of unity and the waves were elliptically polarized and of large fractional amplitude. On both days there was a feature of the density power spectrum at the MHD carrier wave frequency attributable to oblique propagation of the waves with propagation angles of a few degrees with respect to the mean field. Ponderomotive effects due to spatial gradient in the MHD wave energy density are proposed as responsible for a correlation betweeen density and transverse wave intensity on both days. Generation of density fluctuations by linear polarized MHD waves is not an important contributor to the observed density fluctuations.

Spangler, Steven