Search NASA⌕ Search

Engineering topics

Anderson, J. R.

Publications and source records attributed to Anderson, J. R..

At least 19 records

Spacecraft Induced Molecular Return Flux Considerations for Icy Moon Missions Targeting Detection of Organics with Mass Spectrometers

Science missions targeting the detection of organics from jet plumes originating from icy moons (i.e. Europa and Enceladus) will employ next-generation, state-of-the-art mass spectrometers to measure the composition of icy moon plume effluents and exospheres. During fly-bys, as mass spectrometers make their scientific measurements, molecular emissions from the spacecraft can interact with the local exosphere and associated jet plumes from the sub-surface oceans of the icy moons. Spacecraft-induced molecular effluents collide with molecules from the ambient exosphere, and a fraction of the spacecraft emissions are returned to the spacecraft and its complement of science instruments. The rate at which emitted molecules are returned to the spacecraft by collisions with other molecules (e.g. in Europa’s exosphere) is the return flux. The return flux of molecular emission from spacecraft sources is a major contributor to contaminant deposition onto the complement of contamination-sensitive instruments. Characterization of return flux is critical to the definition of requirements for materials outgassing for the spacecraft and its instruments, and for the definition of thruster operations.

Soares, C. E.↗

The microwave Hall effect measured using a waveguide tee

This paper describes a simple microwave apparatus to measure the Hall effect in semiconductor wafers. The advantage of this technique is that it does not require contacts on the sample or the use of a resonant cavity. Our method consists of placing the semiconductor wafer into a slot cut in an X-band (8–12 GHz) waveguide series tee, injecting microwave power into the two opposite arms of the tee, and measuring the microwave output at the third arm. A magnetic field applied perpendicular to the wafer gives a microwave Hall signal that is linear in the magnetic field and which reverses phase when the magnetic field is reversed. The microwave Hall signal is proportional to the semiconductor mobility, which we compare for calibration purposes with d.c. mobility measurements obtained using the van der Pauw method. We obtain the resistivity by measuring the microwave reflection coefficient of the sample. This paper presents data for silicon and germanium samples doped with boron or phosphorus. The measured mobilities ranged from 270 to 3000 cm{sup 2}/(V s).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma etching of superconducting Niobium tips for scanning tunneling microscopy

We have developed a reproducible technique for the fabrication of sharp superconducting Nb tips for scanning tunneling microscopy (STM) and scanning tunneling spectroscopy. Sections of Nb wire with 250 μm diameter are dry etched in an SF₆ plasma in a Reactive Ion Etcher. The gas pressure, etching time, and applied power are chosen to control the ratio of isotropic to anisotropic etch rates and produce the desired tip shape. The resulting tips are atomically sharp, with radii of less than 100 nm, mechanically stable, and superconducting. They generate good STM images and spectroscopy on single crystal samples of Au(111), Au(100), and Nb(100), as well as a doped topological insulator Bi₂Se₃ at temperatures ranging from 30 mK to 9 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A 30 mK, 13.5 T scanning tunneling microscope with two independent tips

We describe the design, construction, and performance of an ultra-low temperature, high-field scanning tunneling microscope (STM) with two independent tips. The STM is mounted on a dilution refrigerator and operates at a base temperature of 30 mK with magnetic fields of up to 13.5 T. We focus on the design of the two-tip STM head, as well as the sample transfer mechanism, which allows in situ transfer from an ultra high vacuum preparation chamber while the STM is at 1.5 K. Other design details such as the vibration isolation and rf-filtered wiring are also described. Their effectiveness is demonstrated via spectral current noise characteristics and the root mean square roughness of atomic resolution images. The high-field capability is shown by the magnetic field dependence of the superconducting gap of Cu{sub x}Bi{sub 2}Se{sub 3}. Finally, we present images and spectroscopy taken with superconducting Nb tips with the refrigerator at 35 mK that indicate that the effective temperature of our tips/sample is approximately 184 mK, corresponding to an energy resolution of 16 μeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model of hollow cathode operation and life limiting mechanisms

In this paper we apply results from the extensive traveling wave tube vacuum barium impregnated cathode literature to the hollow cathodes used in ion thrusters. We show that the observed space station cathode life is in general agreement with published barium evaporation rates.

hollow cathodes↗

Numerical simulations of ion thruster accelerator grid erosion

The highly successful demonstration of ion propulsion on Deep Space 1 has stimulated the study of more demanding applications of ion propulsion. These future applications require ion thrusters capable of providing significantly greater specific impulses and total impulses than the current state-of-the-art Higher specific impulses aggravate the known wear out mechanisms of the ion accelerator system.

ion thruster SEP electric propulsion ion propulsio↗

A model of hollow cathode plasma chemistry

We have developed a new model of hollow cathode plasma chemistry based on the observation that xenon ion mobility is diffusion limited due to resonant charge exchange reactions. The model shows that vapor phase barium atoms are ionized almost immediately and electric fields accelerate the ions upstream from the emission zone. We have also applied the model to the orifice region, where the resultant ion generation profile correlates with previously reported orifice erosion.

hollow cathode↗