Development of a London moment readout for a superconducting gyroscope

A gyroscope for verifying certain predictions of General Relativity is under development at Stanford. A method of measuring the gyroscope orientation based on the use of the London moment and a SQUID magnetometer is described. It is estimated that the required sensitivity of 1 milliarc-sec can be achieved in a bandwidth of 2.5 times 10 to the -6th Hz.

Anderson, J. T.↗

Signal detection in l/f noise of SQUID magnetometers

It is shown that the variance on the SQUID power spectrum in the l/f low frequency region is well behaved, i.e., any small frequency band may be treated as white noise in standard power spectrum estimation theory. Specifically a calibration signal is examined at 0.017 Hz with an equivalent energy referred to the SQUID input coil of 1 times 10 to the -30th J and a digitally recorded and analyzed record of 140 hr duration obtained an optimum S/N better than 400. The results are in good agreement with theory. In addition no deviation from the l/f dependence of the noise energy spectrum is seen down to frequencies below 10 to the -5th Hz. A commercially available SQUID and electronics system were used.

Cabrera, B.↗

A high accuracy all-angle gyroscope readout using quantized flux

Means are described to use SQUID magnetometer flux counting and the London moment of a spherical superconducting gyroscope to read out the gyroscope spin axis direction to an accuracy of at least 23 bits per quadrant. The system is discussed in analogy to optical fringe counting as applied to distance measurement. Several methods of applying both analog and digital SQUID magnetometers to the readout problem are given, as well as limitations on each. Described are two methods of increasing the flux available for measurement: magnetizing the gyroscope with a trapped field, and optimizing readout circuit inductances. Finally, the same principle on which the gyroscope readout is based is applied to a description of a high accuracy, flux counting, digital angle encoder.

Anderson, J. T.↗

Perform a gyro test of general relativity in a satellite and develop associated control technology

The progress accomplished in the Stanford Gyro Relativity program during the period November 1974 to October 1975 was described. Gyro developments were continued in the main laboratory dewar, concentrating on the operation of a three axis gyro readout and on improvements to the methods of canceling trapped fields in the rotor; these efforts culminated in the first successful observation of the London moment in the spinning gyro rotor in March 1975. Following a review meeting at that time, a new goal was formulated for the next 12 to 18 months, namely to operate a gyroscope in the new ultra-low field facility with readout resolution approaching 1 arc-second. The following other tasks were also completed: (1) sputtering work, (2) magnetometry, (3) construction and installation of the North Star simulator, (4) analysis of torques on the gyro, especially in inclined orbits, (5) equivalence principle accelerometer, and (6) analysis of a twin-satellite test of relativity.

Fairbank, W. M.↗