Search NASASearch

Engineering topics

Anderson, R. H.

Publications and source records attributed to Anderson, R. H..

Atrial development in the human heart: an immunohistochemical study with emphasis on the role of mesenchymal tissues

The development of the atrial chambers in the human heart was investigated immunohistochemically using a set of previously described antibodies. This set included the monoclonal antibody 249-9G9, which enabled us to discriminate the endocardial cushion-derived mesenchymal tissues from those derived from extracardiac splanchnic mesoderm, and a monoclonal antibody recognizing the B isoform of creatine kinase, which allowed us to distinguish the right atrial myocardium from the left. The expression patterns obtained with these antibodies, combined with additional histological information derived from the serial sections, permitted us to describe in detail the morphogenetic events involved in the development of the primary atrial septum (septum primum) and the pulmonary vein in human embryos from Carnegie stage 14 onward. The level of expression of creatine kinase B (CK-B) was found to be consistently higher in the left atrial myocardium than in the right, with a sharp boundary between high and low expression located between the primary septum and the left venous valve indicating that the primary septum is part of the left atrial gene-expression domain. This expression pattern of CK-B is reminiscent of that of the homeobox gene Pitx2, which has recently been shown to be important for atrial septation in the mouse. This study also demonstrates a poorly appreciated role of the dorsal mesocardium in cardiac development. From the earliest stage investigated onward, the mesenchyme of the dorsal mesocardium protrudes into the dorsal wall of the primary atrial segment. This dorsal mesenchymal protrusion is continuous with a mesenchymal cap on the leading edge of the primary atrial septum. Neither the mesenchymal tissues of the dorsal protrusion nor the mesenchymal cap on the edge of the primary septum expressed the endocardial tissue antigen recognized by 249-9G9 at any of the stages investigated. The developing pulmonary vein uses the dorsal mesocardium as a conduit to reach the primary atrial segment. Initially, the pulmonary pit, which will becomes the portal of entry for the pulmonary vein, is located along the midline, flanked by two myocardial ridges. As development progresses, tissue remodeling results in the incorporation of the portal of entry of the pulmonary vein in left atrial myocardium, which is recognized because of its high level of creatine. Closure of the primary atrial foramen by the primary atrial septum occurs as a consequence of the fusion of these mesenchymal structures. Copyright 2000 Wiley-Liss, Inc.

NASA Discipline Cardiopulmonary

Construction alignment sensor feasibility demonstrations (laser measurement)

The design theory and trade-offs involved in the selection of laser heterodyne sensors for use in active control of spacecraft structures are discussed. These sensors include a HeNe distance measuring system for structures requiring accuracies to .1 mm, a CO2 distance measuring system for measuring unambiuously down to .01 microns, and vibration sensors based on both HeNe and CO2 lasers.

Anderson, R. H.

Structural Alignment Sensor Feasibility Demonstration

A structural alignment sensor (SAS) was developed for use with large deployable antenna systems for contour measurement and/or active control. The SAS is a laser ranging system using frequency modulation and accurate phase measurement to determine distance. Work was done with a CO2 and HeNe laser. The capability of the SAS to measure antenna rib contours was studied over ranges of 50 meters to a resolution of 100 microns. Initial resolution data was taken with the CO2 system. This data shows that it will indeed meet the SAS requirements. The development of the HeNe system was initiated because it offers substantial improvement in size, weight, and power over the CO2 system. The final demonstration was made with the HeNe system and it too showed that the SAS requirements could be met with this alternate approach. The projection of these results to a conceptual design for a flight system and its application are described.

Anderson, R. H.

Scanning mirror for infrared sensors

A high resolution, long life angle-encoded scanning mirror, built for application in an infrared attitude sensor, is described. The mirror uses a Moire' fringe type optical encoder and unique torsion bar suspension together with a magnetic drive to meet stringent operational and environmental requirements at a minimum weight and with minimum power consumption. Details of the specifications, design, and construction are presented with an analysis of the mirror suspension that allows accurate prediction of performance. The emphasis is on mechanical design considerations, and brief discussions are included on the encoder and magnetic drive to provide a complete view of the mirror system and its capabilities.

Anderson, R. H.