Search NASA⌕ Search

Engineering topics

Anliker, E.

Publications and source records attributed to Anliker, E..

Design, Fabrication, and Testing of a 1.9 m Long, 16.5 mm Period NbTi Superconducting Undulator for the Advanced Photon Source Upgrade

Superconducting undulator (SCU) technology has been in use at the Advanced Photon Source since 2013. Due to the successful and reliable operation of the existing SCUs, the Advanced Photon Source upgrade project has decided to expand the use of NbTi-based SCUs. The first new magnets to be designed and fabricated are 1.9 m long with a period length of 16.5 mm. NbTi superconductor is used for coil winding and there are four separate coils wound on the mandrel to produce the main undulator field along with end compensation and distributed dipole compensation. The magnetic design, fabrication details, assembly, and testing are described in detail.

NbTi.↗

A PRELIMINARY CRYOGENIC PERFORMANCE TEST OF THE 4.8-M-LONG CRYOSTAT FOR SUPERCONDUCTING UNDULATORS

A 4.8-m-long cryostat has been developed to cool a pair of 1.9-m-long planar superconducting undulator magnets (SCUs). The final design and the thermal model of this cryocooler-cooled LHe-based cryostat have been completed. The cryostat is fabricated, and a preliminary cooldown test has been performed. This paper presents a comparison between measured and calculated thermal performance of the 4.8-m-long cryostat for the SCU.

Shiroyanagi, Y.↗

A Preliminary Thermal Model of the LHe-based SCAPE Cryostat

The SCAPE (SuperConducting Arbitrarily Polarizing Emitter) undulator is under development at the Advanced Photon Source (APS). This new undulator requires a cryostat that will be designed based on expected heat loads. For instance, the expected heating of the beam chamber by electron beam is estimated to be at a level of 182 W – much higher than in planar SCUs. This and other challenges require careful thermal analysis of the LHe-based SCAPE cryostat. A detailed thermal model of the LHe-based SCAPE cryostat has been created in ANSYS. This paper presents calculated cooling capacity and temperatures of the SCAPE cryostat for the static and dynamic heat loads. Index Terms—SCAPE (SuperConducting Arbitrarily Polarizing Emitter), cryocooler, LHe, thermal isolation, thermal conductance.

Shiroyanagi, Y.↗

Thermal Analysis of a Superconducting Undulator Cryostat for the APS Upgrade

The Advanced Photon Source Upgrade includes four 4.8-m-long superconducting undulator (SCU) cryostats, each containing two planar undulator NbTi magnets up to 1.9 m long. The cooling is provided by six cryocoolers arranged in three thermal circuits. The magnets are indirectly cooled with LHe penetrating through channels in the magnet cores. This 4 K circuit, which also includes a LHe tank, is cooled by five 4 K cryocooler 2nd stages. A beam vacuum, which is thermally isolated from the magnets, is cooled by one 10 K cryocooler 2nd stage. A thermal shield and warm parts of current leads are cooled by the 1st stages of all six cryocoolers. This paper presents an ANSYS-based thermal analysis of the new SCU cryostat including all thermal circuits. The benchmarked thermal conductance between the cryocooler cold heads and the LHe tank are used in the calculations as well as the measured cryocooler load lines. The model predicts temperatures in the system, total 4 K heat loads, and excess cooling power for various operational modes of the undulator.

Shiroyanagi, Y.↗

A New Superconducting Undulator Cryostat for the APS Upgrade

The Advanced Photon Source (APS) is in the midst of a major facility upgrade including both a new electron storage ring (SR) and many new insertion devices ( IDs) providing x-ray photon beams to a new suite of experimental end stations. Included among the new IDs are four 4.8-meter superconducting undulator (SCU) cryostats, each containing two 1.8-meter planar undulator magnets operating at 4.2 K in either a phase shifted or canted configuration. We describe a new, compact cryocooler-based cryostat design which supports the magnets and associated subsystems and also fits the space constraints of the SR ID straight sections. The design is an evolution of earlier single-magnet 2-meter cryostats, retaining some subsystem commonality while incorporating lessons learned and several features unique to the challenge of supporting two independently operable undulator magnets in a single device.

Anliker, E.↗