Appelhans, Anthony D

Publications and source records attributed to Appelhans, Anthony D.

Characterization of Coordination Complexes by Desorption Electrospray Mass Spectrometry with a Capillary Target

Metal coordination complexes were formed directly from liquid surfaces using desorption electrospray ionization (DESI) mass spectrometry. The approach is attractive because it separates complexities of ESI spray droplet formation from delivery of the analyte solution, and thereby gets around difficulty resulting from alteration of the spray process by changes in solution chemistry. Cs+, Ba2+, and La3+ coordination complexes were formed using 18-crown-6 (18c6) and triethylphosphate (TEP) as ligands (L), that had the general formula [Mn+(NO3-)n-1(L)m]+. Formation of singly charged cation complexes was preferred, with charge reduction at the metal site accomplished by attachment of nitrate. Using TEP as a model phosphoryl ligand, alkali metals coordinate with up to three ligands, with Cs+ preferring fewer than Na+. Ba2+ and La3+ are formed as ion pair complexes [Ba(NO3)]+ and [La(NO3)2]+, and both will coordinate with up to four TEP ligands. Using 18c6, Cs+ forms a bis-ligand complex. In contrast, [Ba(NO3)]+ prefers a single 18c6 ligand, while La forms mainly [La(NO3)2(18c6)]+, for which DFT calculations suggested a structure in which the nitrate ligands occupy pseudo-axial positions on opposing sides of the crown. Lower abundances of bis-18c6 complexes were also formed together with doubly charged [La(NO3)(18c6)n]2+ complexes (n = 2 – 4). The results suggest an alternative strategy for probing metal speciation in solution that is less perturbed by the droplet formation and ionization mechanisms operating in conventional electrospray ionization mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrostatic dispersion lenses and ion beam dispersion methods

An EDL includes a case surface and at least one electrode surface. The EDL is configured to receive through the EDL a plurality of ion beams, to generate an electrostatic field between the one electrode surface and either the case surface or another electrode surface, and to increase the separation between the beams using the field. Other than an optional mid-plane intended to contain trajectories of the beams, the electrode surface or surfaces do not exhibit a plane of symmetry through which any beam received through the EDL must pass. In addition or in the alternative, the one electrode surface and either the case surface or the other electrode surface have geometries configured to shape the field to exhibit a less abrupt entrance and/or exit field transition in comparison to another electrostatic field shaped by two nested, one-quarter section, right cylindrical electrode surfaces with a constant gap width.

Dahl, David A↗

Multi-collector Isotope Ratio Mass Spectrometer -- Operational Performance Report

This report describes the operational testing of a new magnetic sector mass spectrometer that utilizes seven full-sized discrete dynode electron multipliers operating simultaneously. The instrument includes a newly developed ion dispersion lens that enables the mass dispersed individual isotope beams to be separated sufficiently to allow a full-sized discrete dynode pulse counting multiplier to be used to measure each isotope beam. The performance of the instrument was measured using SRM 996 (244Pu spike) at loadings of 2.4 and 12 fg on resin beads and with SRM 4350B Columbia River Sediment samples. The measured limit of detection (3s) for 240Pu was 3.4 attograms for SRM 996. The limit of quantitation (LOQ), defined as 10 s, was 11.2 attograms. The measured concentration of 239Pu in the CRS standard was 152 ± 6 fg/g.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion mobility spectrometers and methods for ion mobility spectrometry

An ion mobility spectrometer may include an inner electrode and an outer electrode arranged so that at least a portion of the outer electrode surrounds at least a portion of the inner electrode and defines a drift space therebetween. The inner and outer electrodes are electrically insulated from one another so that a non-linear electric field is created in the drift space when an electric potential is placed on the inner and outer electrodes. An ion source operatively associated with the ion mobility spectrometer releases ions to the drift space defined between the inner and outer electrodes. A detector operatively associated with at least a portion of the outer electrode detects ions from the drift space.

47 OTHER INSTRUMENTATION↗

Continuous sampling ion mobility spectrometers and methods therefor

An ion mobility spectrometer may include a flow channel having an inlet end and an outlet end. A deflection electrode is positioned within the flow channel so that a non-linear electric field is created between at least a portion of the flow channel and at least a portion of the deflection electrode when an electrostatic potential is placed across the deflection electrode and the flow channel. The ion mobility spectrometer also includes means for producing ions at a position upstream from the leading edge of the deflection electrode, so that ions produced thereby are deflected by the deflection electrode into the non-linear electric field. A detector positioned within the flow channel for detects ions from the non-linear electric field.

47 OTHER INSTRUMENTATION↗