Search NASA⌕ Search

Engineering topics

Apt, Jay

Publications and source records attributed to Apt, Jay.

Could on-site fuel storage economically reduce power plant-gas grid dependence in pipeline constrained areas like New England?

In the Northeastern United States, natural gas supply constraints have led to periods when gas shortages have caused up to a quarter of all unscheduled power plant outages. Dual fuel oil/gas generators or local gas storage might mitigate gas supply shortages. We use historical power plant operational and availability data to develop a supply curve of the costs required for generators to mitigate fuel shortage failures in New England. Based on 2012–2018 data, we find that the historical fuel shortages at approximately 2 GW worth of gas-fired capacity could be mitigated using on-site fuel storage. For comparison, New England’s average reserve margin was 1.7–2.8 GW over our sample period. Oil dual fuel plants would recoup their investment if compensated with a reliability adder of $\$ 3-7$/MWh during their normal operations, while $\$ 7-16$/MWh would incentivize using onsite, compressed natural gas storage. We estimate that the capital expenses associated with the fuel storage options would be less expensive than installing battery backup for resource adequacy at current battery prices.

03 NATURAL GAS↗

Geographic smoothing of solar photovoltaic electric power production in the Western USA

We examined the geographic smoothing of solar photovoltaic generation from 15 utility-scale plants in California, Nevada, and Arizona and from 19 commercial building installations in California. This is the first comparison of geographic smoothing from utility-scale and building-mounted PV and the first examination of solar PV smoothing in this region. Our research questions were (1) how does geographic smoothing of commercial building rooftop PV compare to that of utility scale PV?, (2) is the geographic smoothing found for utility-scale plants the same for the western US as in India?, and (3) how does the geographic smoothing for PV compare to that of wind? By examining the power output of these generators in the frequency domain, we quantified the smoothing obtained by combining the output of geographically separated plants. We found that utility-scale and commercial rooftop plants exhibited similar geographic smoothing, with 10 combined plants reducing the amplitude of fluctuations at 1 h to 18%–28% of those seen for a single plant. We find that combining a few PV sites together reduces fluctuations, but that the point of quickly diminishing returns is reached after ∼5 sites, and that for all the locations and plant sizes considered, PV does not exhibit as much geographic smoothing as is seen for combining wind plants. We present preliminary theoretical arguments for why geographic smoothing of PV plants is less effective than that for wind plants. The slope of the high-frequency part of the PV power spectrum can at best be geographically smoothed (steepen) to an asymptotic spectrum of [Formula: see text]. This limit for PV has considerably less smoothing than that for wind's geographic smoothing, shown theoretically and from observed data to be [Formula: see text].

Klima, Kelly↗

Geographic smoothing of solar PV: Results from Gujarat

We examine the potential for geographic smoothing of solar photovoltaic (PV) electricity generation using 13 months of observed power production from utility-scale plants in Gujarat, India. To our knowledge, this is the first published analysis of geographic smoothing of solar PV using actual generation data at high time resolution from utility-scale solar PV plants. We use geographic correlation and Fourier transform estimates of the power spectral density (PSD) to characterize the observed variability of operating solar PV plants as a function of time scale. Most plants show a spectrum that is linear in the log–log domain at high frequencies f, ranging from f -1.23 to f -1.56 (slopes of -1.23 and -1.56), thus exhibiting more relative variability at high frequencies than exhibited by wind plants. PSDs for large PV plants have a steeper slope than those for small plants, hence more smoothing at short time scales. Interconnecting 20 Gujarat plants yields a f -1.66 spectrum, reducing fluctuations at frequencies corresponding to 6 h and 1 h by 23% and 45%, respectively. Half of this smoothing can be obtained through connecting 4-5 plants; reaching marginal improvement of 1% per added plant occurs at 12-14 plants. The largest plant (322 MW) showed an f -1.76 spectrum. Furthermore, this suggests that in Gujarat the potential for smoothing is limited to that obtained by one large plant.

14 SOLAR ENERGY↗

The RenewElec Project: Variable Renewable Energy and the Power System (Final Report)

Variable energy resources, such as wind power, now produce about 4% of U.S. electricity. They can play a significantly expanded role if the U.S. adopts a systems approach that considers affordability, security and reliability. Reaching a 20-30% renewable portfolio standard goal is possible, but not without changes in the management and regulation of the power system, including accurately assessing and preparing for the operational effects of renewable generation. The RenewElec project will help the nation make the transition to the use of significant amounts of electric generation from variable and intermittent sources of renewable power.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Conventional Generation Asset Management with Renewable Portfolio Standards Using Real Options

The transition to a more renewable generation mix under a competitive electricity market will require individual power producers to use sophisticated tools to value conventional generators. Owners will need to understand what market prices signal new investments, temporarily suspending operation, reactivating mothballed generators or permanently abandoning a plant. Net present valuation from a traditional discounted cash flow analysis is limited in capturing the value of generation technologies, and it does not provide an optimal investment criterion. We present and evaluate a closed-form decision support framework using a Spark Spread Real Options approach to value generation assets and to capture optimal market price signals that minimizes financial risks of individual power producers under a transition towards a more renewable energy fleet. We evaluate the Spark Spread options valuation for capital budgeting without capacity payments. As an example, for a fixed heat rate of 10,000 Btu/kWh and a combined electricity and fuel price annual volatility1 of 58%, the Spark Spread option valuation gives a positive value for a unit of installed generating capacity at electricity prices below $\$$40/MWh. Given the same conditions, a traditional net present value (NPV) cash flow has no value for a unit of installed capacity for electricity prices below $\$$40/MWh. Accounting for the inevitable volatility in electricity and fuel prices can allow firms to see more value in fossil plants than does the traditional approach.

17 WIND ENERGY↗

Thermal Plant Emissions Due to Intermittent Renewable Power Integration

Twenty five U.S. states have enacted some form of renewables portfolio standards (RPS) for electricity generation and Congress is considering a national renewable electricity standard (RES). Wind power, the fastest-growing renewable energy source, exhibits significant output variability, as shown at the two time scales in Figures 1 and 2. The first shows variability for a single turbine at 1 second and slower, while the second shows that even in a large system with over a thousand wind turbines, the wind exhibits both short- and long-term variability. Solar power exhibits similar fluctuations. At the present low penetration of variable renewables (1.3% of U.S. net generation in 2008), these fluctuations can be largely ignored except in control areas where wind is a much larger fraction of generation than the national average. At the levels required by state RPS legislation (for example, 20% in California and 12% in New Jersey), the effects of variability and intermittency are no longer negligible. To provide a substantial portion of a state's electricity, wind power must be coupled with a firm power source to accommodate the fluctuations. Where significant hydro-electric storage is not available (or during drought years), combustion plants with fast ramping capabilities are likely to be used to ensure a steady and stable supply of electricity until cost breakthroughs are made in energy storage systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Near-term implications of a ban on new coal-fired power plants in the United States

Large numbers of proposed new coal power generators in the United States have been cancelled, and some states have prohibited new coal power generators. We examine the effects on the U.S. electric power system of banning the construction of coal-fired electricity generators, which has been proposed as a means to reduce U.S. CO{sub 2} emissions. The model simulates load growth, resource planning, and economic dispatch of the Midwest Independent Transmission System Operator (ISO), Inc., Electric Reliability Council of Texas (ERCOT), and PJM under a ban on new coal generation and uses an economic dispatch model to calculate the resulting changes in dispatch order, CO{sub 2} emissions, and fuel use under three near-term (until 2030) future electric power sector scenarios. A national ban on new coal-fired power plants does not lead to CO{sub 2} reductions of the scale required under proposed federal legislation such as Lieberman-Warner but would greatly increase the fraction of time when natural gas sets the price of electricity, even with aggressive wind and demand response policies. 50 refs., 5 figs., 4 tabs.

20 FOSSIL-FUELED POWER PLANTS↗

Short run effects of a price on carbon dioxide emissions from U.S. electric generators

The price of delivered electricity will rise if generators have to pay for carbon dioxide emissions through an implicit or explicit mechanism. There are two main effects that a substantial price on CO{sub 2} emissions would have in the short run (before the generation fleet changes significantly). First, consumers would react to increased price by buying less, described by their price elasticity of demand. Second, a price on CO{sub 2} emissions would change the order in which existing generators are economically dispatched, depending on their carbon dioxide emissions and marginal fuel prices. Both the price increase and dispatch changes depend on the mix of generation technologies and fuels in the region available for dispatch, although the consumer response to higher prices is the dominant effect. We estimate that the instantaneous imposition of a price of $35 per metric ton on CO{sub 2} emissions would lead to a 10% reduction in CO{sub 2} emissions in PJM and MISO at a price elasticity of -0.1. Reductions in ERCOT would be about one-third as large. Thus, a price on CO{sub 2} emissions that has been shown in earlier work to stimulate investment in new generation technology also provides significant CO{sub 2} reductions before new technology is deployed at large scale. 39 refs., 4 figs., 2 tabs.

20 FOSSIL-FUELED POWER PLANTS↗

Storing syngas lowers the carbon price for profitable coal gasification

Integrated gasification combined cycle (IGCC) electric power generation systems with carbon capture and sequestration have desirable environmental qualities but are not profitable when the carbon dioxide price is less than approximately $50 per metric ton. We examine whether an IGCC facility that operates its gasifier continuously but stores the syngas and produces electricity only when daily prices are high may be profitable at significantly lower CO{sub 2} prices. Using a probabilistic analysis, we have calculated the plant-level return on investment (ROI) and the value of syngas storage for IGCC facilities located in the U.S. Midwest using a range of storage configurations. Adding a second turbine to use the stored syngas to generate electricity at peak hours and implementing 12 h of above-ground high-pressure syngas storage significantly increases the ROI and net present value. Storage lowers the carbon price at which IGCC enters the U.S. generation mix by approximately 25%. 36 refs., 7 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Should a coal-fired power plant be replaced or retrofitted?

In a cap-and-trade system, a power plant operator can choose to operate while paying for the necessary emissions allowances, retrofit emissions controls to the plant, or replace the unit with a new plant. Allowance prices are uncertain, as are the timing and stringency of requirements for control of mercury and carbon emissions. We model the evolution of allowance prices for SO{sub 2}, NOx, Hg, and CO{sub 2} using geometric Brownian motion with drift, volatility, and jumps, and use an options-based analysis to find the value of the alternatives. In the absence of a carbon price, only if the owners have a planning horizon longer than 30 years would they replace a conventional coal-fired plant with a high-performance unit such as a supercritical plant; otherwise, they would install SO{sub 2} and NOx controls on the existing unit. An expectation that the CO{sub 2} price will reach $50/t in 2020 makes the installation of an IGCC with carbon capture and sequestration attractive today, even for planning horizons as short as 20 years. A carbon price below $40/t is unlikely to produce investments in carbon capture for electric power. 1 ref., 5 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Deregulation/Restructuring part II: where Do we go from here?

The authors reject calls for reregulation. An alternative is to solicit offers for long-term contracts that specify fixed and generating prices for each plant. The contracts would specify the number of times a generator could be asked to shut down, as well as the availability and reliability of the unit. Units whose offers are accepted would be paid their fixed offer if they complied with the terms of the contract and their generation offer for each MWh they were asked to supply. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗