Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector

We present constraints on low mass dark matter-electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of $6.1\,\mathrm{g\cdot days}$ of exposure produces exclusion limits for dark matter-electron scattering cross-sections for masses as low as $1\,\mathrm{MeV}/c^2$, as well as on the photon-dark photon mixing parameter and the coupling constant between axion-like particles and electrons for particles with masses $>1.2\,\mathrm{eV}/c^2$ probed via absorption processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Antihelium-3 sensitivity for the GRAMS experiment

The Gamma-Ray and AntiMatter Survey (GRAMS) is a next-generation balloon/satellite mission utilizing a Liquid Argon Time Projection Chamber (LArTPC) detector to measure both MeV gamma rays and antinuclei produced by dark matter annihilation or decay. The GRAMS can identify antihelium-3 events based on the measurements of X-rays and charged pions from the decay of the exotic atoms, Time of Flight (TOF), energy deposition, and stopping range. This paper shows the antihelium-3 sensitivity estimation using a GEANT4 Monte Carlo simulation. For the proposed long-duration balloon (LDB) flight program (35 days x 3 flights) and future satellite mission (2-year observation/10-year observation), the sensitivities become 1.47 × 10 −7 [m 2 s sr GeV/n] −1 and 1.55 × 10 −9 [m 2 s sr GeV/n] −1 /3.10 x 10 -10 [m 2 s sr GeV/n] −1 , respectively. The results indicate that GRAMS can extensively investigate various dark matter models through the antihelium-3 measurements.

Antihelium-3↗

First Measurement of the Nuclear-Recoil Ionization Yield in Silicon at 100 eV

We measured the nuclear-recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4 keV down to 100 eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100 eV. In conclusion, these results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity of the GAPS experiment to low-energy cosmic-ray antiprotons

The General Antiparticle Spectrometer (GAPS) is an upcoming balloon mission to measure low-energy cosmic-ray antinuclei during at least three ~35-day Antarctic flights. With its large geometric acceptance and novel exotic atom-based particle identification, GAPS will detect ~500 cosmic antiprotons per flight and produce a precision cosmic antiproton spectrum in the kinetic energy range of ~0.07–0.21 GeV/n at the top of the atmosphere. With these high statistics extending to lower energies than any previous experiment, and with complementary sources of experimental uncertainty compared to traditional magnetic spectrometers, the GAPS antiproton measurement will be sensitive to dark matter, primordial black holes, and cosmic ray propagation. The antiproton measurement will also validate the GAPS antinucleus identification technique for the antideuteron and antihelium rare-event searches. Finally, this analysis demonstrates the GAPS sensitivity to cosmic-ray antiprotons using a full instrument simulation and event reconstruction, and including solar and atmospheric effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources

Two photo-neutron sources, Y 88 Be 9 and Sb 124 Be 9 , have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. In this study, we evaluate the yield for nuclear recoil energies between 1 and 7 keV at a temperature of ~ 50 mK . We use a geant4 simulation to model the neutron spectrum assuming a charge yield model that is a generalization of the standard Lindhard model and consists of two energy dependent parameters. We perform a likelihood analysis using the simulated neutron spectrum, modeled background, and experimental data to obtain the best fit values of the yield model. The ionization yield between recoil energies of 1 and 7 keV is shown to be significantly lower than predicted by the standard Lindhard model for germanium. There is a general lack of agreement among different experiments using a variety of techniques studying the low energy range of the nuclear recoil yield, which is most critical for interpretation of direct dark matter searches. This suggests complexity in the physical process that many direct detection experiments use to model their primary signal detection mechanism and highlights the need for further studies to clarify underlying systematic effects that have not been well understood up to this point.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraints on Lightly Ionizing Particles from CDMSlite

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved effcient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than e/(3x10^5), as well as the strongest limits for charge <= e/160, with a minimum vertical intensity of 1.36 x 10^-7 cm^-2s^-1sr^-1 at charge e/160. These results apply over a wide range of LIP masses (5 MeV/c^2 to 100 TeV/c^2) and cover a wide range of beta-gamma values (0.1--10^6), thus excluding non-relativistic LIPs with beta-gamma as small as 0.1 for the first time.

Alkhatib, I↗

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of 4.92 +/- 0.01 eV. This exclusion analysis sets the most stringent dark matter-nucleon cross-section limits for masses from 87--140 MeV/c^2 , with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientic potential of athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

Alkhatib, I↗

Cosmic antihelium-3 nuclei sensitivity of the GAPS experiment

The General Antiparticle Spectrometer (GAPS) is an Antarctic balloon experiment designed for low-energy (0.1-0.3 GeV/n) cosmic antinuclei as signatures of dark matter annihilation or decay. GAPS is optimized to detect low-energy antideuterons, as well as to provide unprecedented sensitivity to low-energy antiprotons and antihelium nuclei. The novel GAPS antiparticle detection technique, based on the formation, decay, and annihilation of exotic atoms, provides greater identification power for these low-energy antinuclei than previous magnetic spectrometer experiments. This work reports the sensitivity of GAPS to detect antihelium-3 nuclei, based on full instrument simulation, event reconstruction, and realistic atmospheric influence simulations. The report of antihelium nuclei candidate events by AMS-02 has generated considerable interest in antihelium nuclei as probes of dark matter and other beyond the Standard Model theories. GAPS is in a unique position to detect or set upper limits on the cosmic antihelium nuclei flux in an energy range that is essentially free of astrophysical background. In three 35-day long-duration balloon flights, GAPS will be sensitive to an antihelium flux on the level of $1.3^{+4.5}_{-1.2} $ ∙ 10 -6 m -2 sr -1 s -1 (GeV/n) -1 (95% confidence level) in the energy range of 0.11-0.3 GeV/n, opening a new window on rare cosmic physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of a large area photon detector for rare event search applications

We present the design and characterization of a large-area Cryogenic PhotoDetector designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector consists of a 45.6 cm 2 surface area by a 1-mm-thick 10.6 g Si wafer. It is instrumented with a distributed network of Quasiparticle-trap-assisted Electrothermal feedback Transition-edge sensors with superconducting critical temperature T c = 41.5 mK to measure a thermal phonons released from interactions with photons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector

This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axionlike particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 g Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 g-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section σ ¯ e is constrained for dark matter masses from 0.5 to 10 4 MeV / c 2 ; in the mass range from 1.2 to 50 eV / c 2 the dark photon kinetic mixing parameter ϵ and the axioelectric coupling constant g a e are constrained. The minimum 90% confidence-level upper limits within the above-mentioned mass ranges are σ ¯ e = 8.7 × 10 - 34 cm 2 , ϵ = 3.3 × 10 - 14 , and g a e = 1.0 × 10 - 9 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing TES Power Noise for Future Single Optical-Phonon and Infrared-Photon Detectors

In this letter, we present the performance of a 100 μm × 400 μm × 40 nm W Transition-Edge Sensor with a critical temperature of 40 mK. This device has a noise equivalent power of 1.5×10-18 W/Hz, in a bandwidth of 2.6 kHz, indicating a resolution for Dirac delta energy depositions of 40 ± 5 meV (rms). The performance demonstrated by this device is a critical step toward developing a O(100) meV threshold athermal phonon detector for low-mass dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation and mitigation of trace 210Pb contamination on copper surfaces

Clean materials are required to construct and operate many low-background physics experiments. High-purity copper has found broad use because of its physical properties and availability. In this paper, we describe methods to assay and mitigate Pb-210 contamination on copper surfaces, such as from exposure to environmental radon or coming from bulk impurities. We evaluated the efficacy of wet etching on commercial samples and observed that Po-210 contamination from the copper bulk does not readily pass into solution. During the etch, the polonium appears to trap at the copper-etchant boundary, such that it is effectively concentrated at the copper surface. We observed a different behavior for Pb-210; high-sensitivity measurements of the alpha emissivity versus time indicate the lowest level of Pb-210 contamination ever reported for a commercial copper surface: 0 +/- 12 nBq/cm2 (1-sigma). Additionally, we have demonstrated the effectiveness of mitigating trace Pb-210 and Po-210 surface backgrounds using custom, high-purity electroplating techniques. These approaches were evaluated utilizing assays performed with an XIA UltraLo-1800 alpha spectrometer.

radon, copper, copper cleaning, dark matter, Pb-21↗

Constraints on dark photons and axionlike particles from the SuperCDMS Soudan experiment

We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of the Theoretical and Experimental Status of Dark Matter Identification with Cosmic-Ray Antideuterons

Recent years have seen increased theoretical and experimental effort towards the first-ever detection of cosmic-ray antideuterons, in particular as an indirect signature of dark matter annihilation or decay. In contrast to indirect dark matter searches using positrons, antiprotons, or gamma-rays, which suffer from relatively high and uncertain astrophysical backgrounds, searches with antideuterons benefit from very suppressed conventional backgrounds, offering a potential breakthrough in unexplored phase space for dark matter. This article is based on the first dedicated cosmic-ray antideuteron workshop, which was held at UCLA in June 2014. It reviews broad classes of dark matter candidates that result in detectable cosmic-ray antideuteron fluxes, as well as the status and prospects of current experimental searches. The coalescence model of antideuteron production and the influence of antideuteron measurements at particle colliders are discussed. This is followed by a review of the modeling of antideuteron propagation through the magnetic fields, plasma currents, and molecular material of our Galaxy, the solar system, the Earth's geomagnetic field, and the atmosphere. Finally, the three ongoing or planned experiments that are sensitive to cosmic-ray antideuterons, BESS, AMS-02, and GAPS, are detailed. As cosmic-ray antideuteron detection is a rare event search, multiple experiments with orthogonal techniques and backgrounds are essential. Therefore, the combination of AMS-02 and GAPS antideuteron searches is highly desirable. Many theoretical and experimental groups have contributed to these studies over the last decade, this review aims to provide the first coherent discussion of the relevant dark matter theories that antideuterons probe, the challenges to predictions and interpretations of antideuteron signals, and the experimental efforts toward cosmic antideuteron detection.

Antideuteron Cosmic ray Dark matter↗