Comparative Analysis of Heat Exchangers for High Temperature High Pressure Helium Component Testing

Helium gas loops have been designed and built to gain a better understanding of the gas thermohydraulic phenomena that take place in a helium system. Some of these loops are used for validation and testing of components for high temperature gas-cooled reactors (HTGRs). However, most of them operate at lower pressure and temperature than an HTGR. While these loops can provide valuable information about gas-cooled reactor components, the operating envelope of the experiment is constrained by the maximum operating conditions of the helium loop. In response to the lack of an experimental facility that can provide the infrastructure needed to validate and test components at nominal pressures and temperatures of HTGRS, the HElium Component Testing Out-of-pile Research (HECTOR) facility was designed at Idaho National Laboratory with the assistance of University of Idaho and Walsh Engineering. With the capability to test at temperatures up to 800°C and pressures of 8MPa, HECTOR serves as a critical tool for the advancement of HTGR technology. The facility's primary role is to provide a controlled, high-fidelity environment for the assessment of component resilience and efficiency under nominal HTGR conditions. In the quest to enhance the efficiency and performance of HECTOR, a comparative analysis of three distinct types of heat exchangers—shell and tube, offset strip fin, and printed-circuit—was conducted, focusing primarily on two critical metrics: the required surface area and pressure drop characteristics. The shell and tube heat exchanger, renowned for its robust design and widespread industrial application, was evaluated against the offset strip fin and the cuttingedge printed-circuit heat exchangers, both of which are lauded for their compactness and thermal effectiveness. This comparative study aims to provide detailed insights into the thermal management capabilities of each heat exchanger type under the conditions inherent to HECTOR, thereby facilitating an informed selection for systems demanding high operational integrity and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Numerical investigation of the AP1000 response following loss-of-coolant accident using PCTRAN and CFD to support R&D of SMRs

Small Modular Reactors (SMRs) present a promising solution for the future of sustainable energy, offering advantages such as reduced waste generation, advanced passive safety features, and potential cost efficiencies. Ongoing research focuses on the design and development of SMRs, addressing challenges through numerical simulations and experimental test data. Given that many next-generation reactors are first-of-a-kind (FOK), current operational reactors serve as valuable benchmarks for understanding various thermal-hydraulic phenomena during postulated design basis accidents (DBAs), including loss-of-coolant accidents (LOCA), main steam line breaks (MSLB), and steam generator tube ruptures (SGTR). This study employs the AP1000 model Personal Computer Transient Analyzer (PCTRAN) to simulate reactor responses to small-break LOCA scenarios, specifically analyzing break sizes of 2 and 10 inches. Additionally, ANSYS FLUENT software is utilized to assess containment responses to large-break LOCAs, focusing on the quantification of decay heat removal via natural convection. Verification of the PCTRAN results is achieved using Westinghouse data, with CFD results corroborating the findings. The outcomes demonstrate strong agreement with Westinghouse data, confirming the accuracy of the simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of AP1000 Small-Break Loss-of-Coolant Accident Using Reactor Transient Simulator

The Westinghouse Electric Company’s Advanced Passive Reactor (AP1000) is characterized by the incorporation of passive safety systems (PSSs) designed to ensure core cooling during transient events. The assessment of PSSs requires evaluation of their performance through a combination of experiments and simulations employing various thermal-hydraulic codes. In addition, detailed evaluation of PSSs for a specific reactor system transient analysis such as loss-of-coolant-accident analysis supports understanding representative integral effects test facility development and the further evolution model development and assessment process. Developing a reactor system code is a complex and time-consuming process that requires significant engineering expertise and effort. It can take several months to even years to complete in the early stages of reactor system design and analysis. However, this process can be expedited through the use of transient simulator models for similar reactor systems, which can be used for lesson learning and training purposes. This study uses the Personal Computer Transient Analyzer (PCTRAN) code. The main advantage of PCTRAN is its ease of use and ability to run faster than real time. This study presents the results obtained for a small-break loss-of-coolant accident (SBLOCA) for two breaks using the full version (licensed) of PCTRAN. The purpose of this investigation is to evaluate the overall system behavior during the postulated SBLOCA event as well as assess the capability of the PCTRAN code to reproduce the system response during transient events. The obtained results were compared with the Westinghouse NOTRUMP system code. The PCTRAN code proved to be reliable in predicting the qualitative behavior of the system in both transient cases. As for the system response, it was found that it is contingent on the activation time of the PSSs. The differences in reactor coolant system pressure between the two codes were attributed to the critical flow model and simplification of mass and energy balance. Despite PCTRAN’s limitations, it can still provide a reasonable prediction of various reactor parameters such as pressure, mass flow rate, and void fraction during a SBLOCA scenario. It is worth noting that PCTRAN currently employs a bulk approach similar to that of the Modular Accident Analysis Program (MAAP) and MELCOR codes. However, the upcoming version of PCTRAN will include an artificial intelligence–based detection and accident prevention system, as well as different models for different reactor components. Consequently, PCTRAN has the potential to be upgraded to match the system thermal-hydraulic codes of the U.S. Nuclear Regulatory Commission and become more widely used in cybersecurity to safeguard nuclear power plants from cyberattacks.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity Analyses of Natural Convection in the AP1000 Passive Containment Cooling System Following LBLOCA Using CFD

The AP1000 power plant has implemented multiple layers of passive safety systems to enhance reactor safety and ensure system integrity during postulated scenarios, such as loss of coolant accident (LOCA) and main steam line break (MSLB). Among these, the passive containment cooling system (PCCS) is a safety-related system designed to prevent the containment from exceeding the design limits of both pressure and temperature following a postulated design basis accident, by transferring heat from the steel containment vessel to the atmosphere. During LOCA, natural air convection plays a vital role in removing heat from the steel containment vessel to the atmosphere. This is integrated with the condensate film from the Passive Containment Cooling Water Storage Tank (PCCWST). Air natural convection is also the only heat removal mechanism after the dry-out of the PCCWST and during the loss of shutdown decay heat removal (LOSDHR) event. Therefore, it is essential to investigate the thermal hydraulics behavior of the containment under transient conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT model developed to analyze the impact of different parameters, such as air relative humidity, air temperature, and steel containment temperature, on the natural convection capability to remove the decay heat following LOCA. The model aims to examine the thermal behavior of the containment and provides a comprehensive understanding of the system's natural convection capability during postulated accidents. The results obtained from the model can be used to improve the safety and integrity of the containment system and provide valuable insights for future research in the field.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Flow Instabilities in boiling channels and their suppression methodologies—A review

Small modular reactors (SMRs) are gaining significant attention as a promising solution for clean and sustainable nuclear-power generation. However, the operation of SMRs is subject to various challenges, including two-phase flow instabilities. Flow instability has the potential to trigger flow-induced vibration and cyclic fluctuations in local thermal stress. These instabilities frequently manifest because of the complex interplay among a multitude of factors, encompassing thermal-hydraulic conditions, the geometric configuration of the steam generator, and operational parameters. These conditions could subsequently lead to premature critical heat flux, equipment malfunctions, and other safety concerns. Here, the endeavor to address steam-generator flow instabilities is of utmost importance in augmenting the sustainability and efficiency of contemporary energy production. This study offers a comprehensive review of instabilities in two-phase flow, with a particular focus on the influential factors impacting the stability of flow boiling. Furthermore, it delves into the processes of identifying, characterizing, and ameliorating these instabilities, emphasizing pivotal findings, methodologies employed, and avenues for prospective research. The primary parameters of concern encompass the efficient transfer of thermal energy, the optimization of mass-flow rates, and the establishment of favorable boundary conditions, all in the context of steam generator design to alleviate instability for water-cooled SMRs. These discernments bear substantial ramifications for enhancing reactor performance and ensuring operational safety.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluating direct vessel injection accident-event progression of AP1000 and key figures of merit to support the design and development of water-cooled small modular reactors

The passive safety systems (PSSs) within water-cooled reactors are meticulously engineered to function autonomously, requiring no external power source or manual intervention. They depend exclusively on inherent natural forces and the fundamental principles of reactor physics, such as gravity, natural convection, and phase changes, to manage, alleviate, and avert the release of radioactive materials into the environment during accident scenarios like a loss-of-coolant accident (LOCA). PSSs are already integrated into such operating commercial reactors as the Advanced Pressurized Reactor-1000 MWe (AP1000) and the Water-Water Energetic Reactor-1200 MWe (WWER-1200) are adopted in most of the upcoming small modular reactor (SMR) designs. Examples of water-cooled SMR PSSs are the passive emergency core-cooling system (ECCS), passive containment cooling system (PCCS), and passive decay-heat removal system, the designs of which vary based on reactor system-design requirements. However, understanding the accident-event progression and phases of a LOCA is pivotal for adopting a specific PSS for a new SMR design. This study covers the accident-event progression for direct vessel injection (DVI) small-break loss-of-coolant accident (SB-LOCA), associated physics phenomena, knowledge gaps, and important figures of merit (FOMs) that may need to be evaluated and assessed to validate thermal-hydraulics models with an available experimental dataset to support new SMR design and development.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Accident event progression, gaps, and key performance indicators for steam generator tube rupture events in water-cooled SMRs: A review

According to historical records of reactor-related incidents, a steam generator tube rupture (SGTR) is one of the most common occurrences at operating pressurized water reactors (PWRs). Such design-basis accidents (DBAs) could lead to a direct path for radionuclides to be released to the atmosphere via the safety and relief valves, making assessments of radionuclide discharge from operating nuclear power plants (NPPs) into the environment crucial for ensuring safety. In such analyses, the primary focus has been on the extent of radioactive release, not the potential damage to the core. Moreover, significant and timely intervention by operators is needed during the initial stages of SGTRs in order to avert overfilling of the SGs, as well as to restrict the dissemination of radioactive materials. Determining the event sequence and phases that occur during an SGTR incident in an advanced passive (e.g., AP1000) water-cooled nuclear reactor is crucial for implementing effective passive safety systems (PSSs) for a specific water-cooled small modular reactor (SMR) design. Here this study provides a comprehensive review of the accident event progression, associated physical phenomena, knowledge gaps, and key performance indicators that must be evaluated and assessed in thermal-hydraulics models, based on relevant test data, respectively.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗