Search NASA⌕ Search

Engineering topics

Armengaud, Eric (ORCID:0000000176005148)

Publications and source records attributed to Armengaud, Eric (ORCID:0000000176005148).

DESI DR1 Ly α 1D power spectrum: Validation of estimators

The Data Release 1 (DR1) of the Dark Energy Spectroscopic Instrument (DESI) is the largest sample to date for small-scale Lyα forest cosmology, accessed through its one-dimensional power spectrum (P 1D ). The Lyα forest P 1D is extracted from quasar spectra that are highly inhomogeneous (both in wavelength and between quasars) in noise properties due to intrinsic properties of the quasar, atmospheric and astrophysical contamination, and also sensitive to low-level details of the spectral extraction pipeline. We employ two estimators in DR1 analysis to measure P 1D : the optimal estimator and the fast Fourier transform (FFT) estimator. To ensure robustness of our DR1 measurements, we validate these two power spectrum and covariance matrix estimation methodologies against the challenging aspects of the data. First, using a set of 20 synthetic 1D realizations of DR1, we derive the masking bias corrections needed for the FFT estimator and the continuum fitting bias needed for both estimators. We demonstrate that both estimators, including their covariances, are unbiased with these corrections using the Kolmogorov-Smirnov test. Second, we substantially extend our previous suite of CCD image simulations to include 675,000 quasars, allowing us to accurately quantify the pipeline's performance. This set of simulations reveals biases at the highest k values, corresponding to a resolution error of a few percent. We base the resolution systematics error budget of DR1 P 1D on these values, but do not derive corrections from them since the simulation fidelity is insufficient for precise corrections.

Lyman alpha forest↗

DESI DR1 Ly α 1D power spectrum: the Fast Fourier Transform estimator measurement

Here, we present the one-dimensional Lyman-α forest power spectrum measurement derived from the data release 1 (DR1) of the Dark Energy Spectroscopic Instrument (DESI). The measurement of the Lyman-α forest power spectrum along the line of sight from high-redshift quasar spectra provides information on the shape of the linear matter power spectrum, neutrino masses, and the properties of dark matter. In this work, we use a Fast Fourier Transform (FFT)-based estimator, which is validated on synthetic data in a companion paper. Compared to the FFT measurement performed on the DESI early data release, we improve the noise characterization with a cross-exposure estimator and test the robustness of our measurement using various data splits. We also refine the estimation of the uncertainties and now present an estimator for the covariance matrix of the measurement. Furthermore, we compare our results to previous high-resolution and eBOSS measurements. In another companion paper, we present the same DR1 measurement using the Quadratic Maximum Likelihood Estimator (QMLE). These two measurements are consistent with each other and constitute the most precise one-dimensional power spectrum measurement to date, while being in good agreement with results from the DESI early data release.

Lyman alpha forest↗

Optimal 1D Ly α forest power spectrum estimation – III. DESI early data

ABSTRACT The 1D power spectrum P1D of the Ly α forest provides important information about cosmological and astrophysical parameters, including constraints on warm dark matter models, the sum of the masses of the three neutrino species, and the thermal state of the intergalactic medium. We present the first measurement of P1D with the quadratic maximum likelihood estimator (QMLE) from the Dark Energy Spectroscopic Instrument (DESI) survey early data sample. This early sample of 54 600 quasars is already comparable in size to the largest previous studies, and we conduct a thorough investigation of numerous instrumental and analysis systematic errors to evaluate their impact on DESI data with QMLE. We demonstrate the excellent performance of the spectroscopic pipeline noise estimation and the impressive accuracy of the spectrograph resolution matrix with 2D image simulations of raw DESI images that we processed with the DESI spectroscopic pipeline. We also study metal line contamination and noise calibration systematics with quasar spectra on the red side of the Ly α emission line. In a companion paper, we present a similar analysis based on the Fast Fourier Transform estimate of the power spectrum. We conclude with a comparison of these two approaches and discuss the key sources of systematic error that we need to address with the upcoming DESI Year 1 analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

The Dark Energy Spectroscopic Instrument: one-dimensional power spectrum from first Ly α forest samples with Fast Fourier Transform

ABSTRACT We present the one-dimensional Ly α forest power spectrum measurement using the first data provided by the Dark Energy Spectroscopic Instrument (DESI). The data sample comprises 26 330 quasar spectra, at redshift z > 2.1, contained in the DESI Early Data Release and the first 2 months of the main survey. We employ a Fast Fourier Transform (FFT) estimator and compare the resulting power spectrum to an alternative likelihood-based method in a companion paper. We investigate methodological and instrumental contaminants associated with the new DESI instrument, applying techniques similar to previous Sloan Digital Sky Survey (SDSS) measurements. We use synthetic data based on lognormal approximation to validate and correct our measurement. We compare our resulting power spectrum with previous SDSS and high-resolution measurements. With relatively small number statistics, we successfully perform the FFT measurement, which is already competitive in terms of the scale range. At the end of the DESI survey, we expect a five times larger Ly α forest sample than SDSS, providing an unprecedented precise one-dimensional power spectrum measurement.

79 ASTRONOMY AND ASTROPHYSICS↗