Process Modeling and Economic Optimization of a Solar Membrane Distillation System.
Abstract not provided.
Engineering topics
Publications and source records attributed to Arnold, R.
Abstract not provided.
Abstract Not Provided
Coherent Smith-Purcell radiation has been demonstrated as a technique for measuring the longitudinal profile of charged particles bunches in the low to intermediate energy range. However, with the advent of the International Linear Collider, the need has arisen for a non-invasive method of measuring the bunch profile at extremely high energies. Smith-Purcell radiation has been used for the first time in the multi-GeV regime to measure the longitudinal profile of the 28GeV SLAC beam. The experiment has both successfully determined the bunch length, and has also demonstrated its sensitivity to bunch profile changes. The challenges associated with this technique, and its prospects as a diagnostic tool are reported here.
The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.
The half-life for double-{beta} decay of {sup 150}Nd has been measured by the NEMO-3 experiment at the Modane Underground Laboratory. Using 924.7 days of data recorded with 36.55 g of {sup 150}Nd, we measured the half-life for 2{nu}{beta}{beta} decay to be T{sub 1/2}{sup 2{nu}}=(9.11{sub -0.22}{sup +0.25}(stat.){+-}0.63(syst.))x10{sup 18} yr. The observed limit on the half-life for neutrinoless double-{beta} decay is found to be T{sub 1/2}{sup 0{nu}}>1.8x10{sup 22} yr at 90% confidence level. This translates into a limit on the effective Majorana neutrino mass of <m{sub {nu}}><4.0-6.3 eV if the nuclear deformation is taken into account. We also set limits on models involving Majoron emission, right-handed currents, and transitions to excited states.
The beam delivery system for the linear collider focuses beams to nanometer sizes at its interaction point, collimates the beam halo to provide acceptable background in the detector and has a provision for state-of-the art beam instrumentation in order to reach the ILCs physics goals. This paper describes the design details and status of the baseline configuration considered for the reference design and also lists alternatives.
T-474 at SLAC is a prototype BPM-based energy spectrometer for the ILC. We describe magnetic measurements and simulations for the 4-magnet chicane used in T-474.
The main physics program of the International Linear Collider requires a measurement of the beam energy with a relative precision of the order 10{sup 4} or better. A magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed to achieve this goal. A prototype spectrometer chicane employing four dipole magnets is currently under development at the End Station A in SLAC, intending to demonstrate the required resolution and stability of this method and investigate possible systematic effects and operational issues. This contribution reports on the successful commissioning of the beam position monitor system and the resolution and stability achieved. Also, the initial results from a run with a full spectrometer chicane are presented.
No abstract prepared.
No abstract prepared.