Search NASASearch

Engineering topics

Aron Bartle

Publications and source records attributed to Aron Bartle.

Development of a High-Fidelity CLARREO Pathfinder Simulator

CLARREO Pathfinder is a hyperspectral instrument designed to resolve reflectance of solar radiation from Earth in the wavelength range of 350 nm to 2300 nm with an uncertainty of 0.3% (k=2) or less. Its success will demonstrate CLARREO’s ability to provide on-orbit SI-Traceable calibration of measured spectral reflectance with an advanced accuracy. The CLARREO pathfinder simulator has been developed to generate high-fidelity inter-calibration event data products that can be used for pre-launch inter-calibration algorithm study. A high-fidelity simulation for CLARREO inter-calibration events includes computationally intensive radiative transfer calculations for observations within each individual collocation footprint. A principal component based radiative transfer model is incorporated in the simulator to enable an ultra-fast forward simulation, ensuring a low latency data processing for month- to year-long intercalibration events. This paper introduces the design and development of the CLARREO pathfinder simulator and some of its applications for inter-calibration matching error evaluation.

Wan Wu

Calibrating CERES and VIIRS using CLARREO Pathfinder: Adjustment for the Viewing Geometry Mismatch

The Climate Absolute Radiance and Refractivity Observatory Pathfinder (CPF) mission on the International Space Station (ISS) will provide, for the first-time, an SI-traceable on-orbit calibration reference with a reflectance uncertainty of 0.3% (1 sigma). One major mission objective is to demonstrate the capability of transferring CPF’s radiometric accuracy to other satellite-based instruments, such as Clouds and Earth's Radiant Energy System (CERES) and Visible Infrared Imaging Radiometer Suite (VIIRS) on NOAA-20. CPF inter-calibration measurements will be planned to obtain inter-calibration samples that closely match satellite-based target sensor observations in time, space, angle, and wavelength. The inter-calibration event observations cover a wide range of viewing geometry angles with potential angular mismatch between CPF and the target sensors which can introduce non-negligible errors against the mission’s inter-calibration uncertainty budget. We will introduce the CPF approach to adjust for angular mismatch differences, thereby reducing the incurred uncertainties to within the inter-calibration uncertainty budget. The angular adjustment algorithm has been developed and validated based on the high-fidelity simulations of the CPF spectra using the Principal Component based Radiative Transfer Model (PCRTM). The implementation of the algorithm on event simulation data and the characterization for the angular adjustment uncertainty will be presented.

Wan Wu

Developing a Spectral Correlation based Method for mitigating Angular Mismatch Effects in Intercalibration Using a Benchmark Hyperspectral Sensor

The CLARREO Pathfinder (CPF) mission will implement a state-of-the-art intercalibration method for transferring CPF’s in-orbit Système Internationale (SI)-traceable reference to the shortwave channel of the Clouds and the Earth’s Radiance Energy System (CERES) and the reflective solar bands of the Visible Infrared Imaging Radiometer Suite (VIIRS) aboard the NOAA-20 satellite platform with a targeted intercalibration methodology uncertainty of 0.3% (k=1). In order to achieve such a high intercalibration accuracy, the CPF intercalibration measurements to be scheduled need to closely match those from CERES and VIIRS in time, space, angles, and wavelength. Despite’s CPF’s two-axis pointing capability to match its boresight line of sight to that of a target sensor, there will be finite residual differences in angular samplings of the two instruments. The potential angular mismatch between CPF and the target sensors can introduce systematic errors in the intercalibration results, and therefore needs to be corrected using a rigorously designed algorithm. The CPF intercalibration team has been developing a correction method for mitigating the impact of these angular anisotropic effects in the CPF-VIIRS and CPF-CERES intercalibration. The method explores the spectral correlation relationship between the reflected solar radiances from the same surface target that would be measured by CPF at two adjacent angles. Our studies have shown that the spectral information based on CPF measurements can be used to accurately predict the spectral radiance or reflectance difference due to a given mismatch in the viewing and solar geometry. The hyper-spectral information can also be used to provide scene stratification without using any auxiliary data, which is critical to reduce the angular correction uncertainty. The angular correction relationship can be well established using simulated CPF-like top-of-atmosphere spectral radiances observed at all sorts of viewing geometry and solar angles and for different scenes. Intensive radiative transfer simulations have been completed using a state-of-art radiative transfer model developed by the CPF team members. The implementation of the algorithm on high-fidelity event simulation data and the characterization for the angular adjustment uncertainty will be presented.

Wan Wu

The Spectral Information Based Angular Correction Methodology for Satellite Intercalibration Applications

Satellite inter-calibration often requires collocated observations with minimized discrepancies in sun-view angles, observation times, and sensor characteristics. The collocation criteria directly impact achievable inter-calibration accuracy. Addressing potential angular mismatches in inter-calibration samples is critical but not as fully recognized and addressed as spatial-temporal mismatches in many studies. To achieve high-accuracy corrections for errors due to mismatched sun-view geometry angles, an angular correction algorithm has been developed for the Climate Absolute Radiance and Refractivity Observatory Pathfinder (CPF) mission. This algorithm uses spectral correlation relationships to estimate differences in spectral radiances measured at different angles. This methodology can be extended for inter-calibrations between sensors measuring band radiances across a broad spectral region. We demonstrate its application in reducing angular mismatch errors between collocated measurements of multi-spectral imaging sensors, using the inter-calibration between the Moderate Resolution Imaging Spectrometer (MODIS) and the Visible Infrared Imaging Radiometer Suite (VIIRS) as an example. The angular correction allows for more relaxed collocation criteria so that more satellite-based inter-calibration samples can be utilized. Furthermore, implementing the angular correction algorithm improves inter-calibration accuracy in applications where angular mismatch errors have not been explicitly addressed previously.

Wan Wu