Development of a Research Reactor Protocol for Neutron Multiplication Measurements

Establishing a protocol for measurements on research reactors is the next step in advanced subcritical neutron multiplication inference measurements. Such measurements can help identify deficiencies and quantify uncertainties in nuclear data and validate predictive Monte Carlo radiation transport simulation capabilities related to subcritical neutron multiplication inference techniques. This work expands on previous benchmark-quality efforts performed at the National Criticality Experiments Research Center (NCERC) located in Nevada, including subcritical experiments with a 4.5-kg {alpha}-phase plutonium sphere surrounded by copper, tungsten and nickel. Evaluations of the nickel and tungsten measurements have both been accepted into the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The nickel benchmark was the first ICSBEP-accepted evaluation of measurements using the Feynman Variance-to-Mean method based on the Hage-Cifarelli formulism, and was the culmination of many years of subcritical experiment research. To help establish a protocol for research reactor-based subcritical measurements, a series of Critical and Subcritical {Phi}-Power Experiments at Rensselaer (CaSPER) have been designed. This neutron multiplication measurement series will be executed at the Rensselaer Polytechnic Institute Walthousen Reactor Critical Facility (RPI-RCF) in upstate New York. The RPI reactor facility can provide benchmark-quality integral experimental configurations where different reactivity states can be achieved by varying the control rod height/water height in the reactor. The diversity of achievable configurations are also unique in contrast to previous subcritical benchmark measurements in that they are spatially complex, involve different materials (fuel, moderator), and are characterized by system-specific neutron cross section sensitivities (various energy ranges and neutron reaction contributions). It is worth noting that previous proof-of-concept subcritical measurements have been performed on thermal systems at NCERC, at a variety of reactivity states by separation distance, yet it was not possible to know the reactivity of various configurations accurately for benchmarking (there are no control rod worth curves as there are no control rods). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

New Science Opportunities Enabled by LCLS-II X-Ray Lasers

This document attempts to capture the most compelling new science opportunities that are enabled by the unique capabilities of the new LCLS-II X-ray laser facility, namely: soft and tender X-rays (0.25 to 5 keV) at high repetition rates (up to 1 MHz) and hard X-rays (up to 25 keV) at 120 Hz. Many compelling areas of science have been identified by the scientific community, through a series of workshops over the past several years, where LCLS-II offers the potential to significantly advance our understanding. This document is not intended to be comprehensive of all the science to be pursued at the future LCLS facility. In particular, it does not capture important ongoing science that will continue to exploit the existing capabilities of the present LCLS facility. Nevertheless, this document will help to establish a scientific foundation for the new facility (encompassing present LCLS capabilities and new LCLS-II capabilities), and will inform LCLS strategic planning and investments over the next 5-10 years. The emphasis of this document is on identifying broad scientific opportunities, elucidating their potential impact, and providing a first-order link between these opportunities and LCLS-II capabilities. Brief descriptions are provided for various experimental approaches to be used, and novel new approaches to be developed, along with select examples of required optics and instruments. However, this document is not intended to capture all the optics and instrumentation requirements. Similarly it does not provide a detailed plan for instrumentation design or for any associated research and development that might be required. Balancing the scientific opportunities and impact, with instrumentation needs, available resources, and infrastructure, will be part of the LCLS planning process which this document will help to inform.

43 PARTICLE ACCELERATORS↗

Demonstration of Single-Crystal Self-Seeded Two-Color X-Ray Free-Electron Lasers

A scheme for generating two simultaneous hard-x-ray free-electron laser pulses with a controllable difference in photon energy is described and then demonstrated using the self-seeding setup at the Linac Coherent Light Source (LCLS). The scheme takes advantage of the existing LCLS equipment, which allows two independent rotations of the self-seeding diamond crystal. The two degrees of freedom are used to select two nearby crystal reflections, causing two wavelengths to be present in the forward transmitted seeding x-ray pulse. The free-electron laser system must support amplification at both desired wavelengths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online Produced Water Treatment Catalog and Decision Tool

The objective of this project was to create an internet-based Water Treatment Technology Catalog and Decision Tool that will increase production, decrease costs and enhance environmental protection. This is to be accomplished by pairing an operator's water treatment cost and capacity needs to specific water treatments. This project cataloged existing and emerging produced water treatment technologies and allows operators to identify the most cost-effective approaches for managing their produced water. The tool captures the cost and capabilities of each technology and the disposal and beneficial use options for each region. The tool then takes location, chemical composition, and volumetric data for the operator's water and identifies the most cost effective treatment options for that water. Regulatory requirements or limitations for each location are also addressed. The Produced Water Treatment Catalog and Decision Tool efficiently matches industry decision makers in unconventional natural gas basins with: 1) appropriate and applicable water treatment technologies for their project, 2) relevant information on regulatory and legal issues that may impact the success of their project, and 3) potential beneficial use demands specific to their project area. To ensure the success of this project, it was segmented into seven tasks conducted in three phases over a three year period. The tasks were overseen by a Project Advisory Council (PAC) made up of stakeholders including state and federal agency representatives and industry representatives. ALL Consulting has made the catalog and decision tool available on the Internet for the final year of the project. The second quarter of the second budget period, work was halted based on the February 18, 2011 budget availability; however previous project deliverables were submitted on time and the deliverables for Task 6 and 7 were completed ahead of schedule. Thus the application and catalog were deployed to the public Internet. NETL did not provide additional funds and work on the project stopped on February 18, 2011. NETL ended the project on March 31, 2012.

03 NATURAL GAS↗

Photon Beamlines and Diagnostics at LCLS

The Linac Coherent Light Source (LCLS) is the first hard-x-ray free electron laser in operation. The turn-on of LCLS was rapid and operation has been reliable. Performance has exceeded the design parameters in several areas. The photon energy output covers a range from 480 eV to over 9 keV; the pulse energy is typically 2-3 mJ, with a maximum of 4 mJ at 2 keV. Electron pulse lengths can be varied from 500 fs to shorter than 10 fs. A low-charge option at 20 pC is being explored, which delivers pulses shorter than 10 fs with a reduced pulse energy, typically around 0.2 mJ. On-demand, single-shot and multi-shot modes up to 60 Hz (planned is 120 Hz) can be made available. The photon diagnostics built for LCLS have been commissioned and provide measurements of various properties of the FEL beam, such as pulse energy, beam size and position, wavelength, and allows for intensity attenuation over the entire wavelength range. The two soft x-ray instruments, the Atomic Molecular and Optics (AMO) and Soft X-ray Material Science (SXR) stations, are fully operational and completed their second user run in mid September 2010. The third user run is scheduled from October to December 2010, and will include the first hard x-ray instrument X-ray Pump-and-Probe (XPP). Three additional hard x-ray stations will follow: CXI (Coherent X-ray Imaging) is planned to start commissioning in December 2010, the XCS (X-ray correlation spectroscopy) instrument will start in June 2011, and the station for Matter in Extreme Conditions (MEC) in 2012. A list of past and future milestones for LCLS commission and operations is shown in table 1. The LCLS hard x-ray Free Electron Laser at SLAC reported first lasing in April of 2009. Since then two successful user runs have been completed at the two soft x-ray stations. The first hard x-ray station has started commissioning in July of 2010. Beam diagnostics play an essential role for tuning the machine and delivering the requested beam properties to the users. An overview of the LCLS photon diagnostics will be presented including some selected commissioning results. Plans for future improvements and upgrades will be briefly discussed.

43 PARTICLE ACCELERATORS↗

Operation and Upgrades of the LCLS*

The LCLS FEL began user operations in September 2009 with photon energies from 800eV to 2 KeV and pulse energies above 2 mJ. Both long pulse (50-200 femtosecond FWHM) and short pulse (<10 femtosecond FWHM at 150 uJ) pulses were delivered at user request. In addition the FEL was operated at fundamental photon energies up to 10 KeV in preparation for hard X-ray experiments. FEL operating parameters, performance and reliability results will be presented, in addition to plans for upgrades to the facility.

Accelerators,ACCPHY, XFEL↗

LCLS Ultrafast Science Instruments:Conceptual Design Report

The Stanford Linear Accelerator Center (SLAC), along with Argonne National Laboratory (ANL), Lawrence Livermore National Laboratory (LLNL), and the University of California at Los Angeles (UCLA), is constructing a Free-Electron Laser (FEL) facility, which will operate in the wavelength range 1.5 nm - 0.15 nm. This FEL, the Linac Coherent Light Source (LCLS), utilizes the SLAC linac and will produce sub-picosecond pulses of short wavelength X-rays with very high peak brightness and almost complete transverse coherence. The final one-third of the SLAC linac will be used as the source of electrons for the LCLS. The high energy electrons will be transported across the SLAC Research Yard, into a tunnel which will house a long undulator. In passing through the undulator, the electrons will be bunched by the force of their own synchrotron radiation and produce an intense, monochromatic, spatially coherent beam of X-rays. By varying the electron energy, the FEL X-ray wavelength will be tunable from 1.5 nm to 0.15 nm. The LCLS will include two experimental halls as well as X-ray optics and infrastructure necessary to create a facility that can be developed for research in a variety of disciplines such as atomic physics, materials science, plasma physics and biosciences. This Conceptual Design Report, the authors believe, confirms the feasibility of designing and constructing three X-ray instruments in order to exploit the unique scientific capability of this new LCLS facility. The technical objective of the LCLS Ultrafast Science Instruments (LUSI) project is to design, build, and install at the LCLS three hard X-ray instruments that will complement the initial instrument included in the LCLS construction. As the science programs advance and new technological challenges appear, instrumentation needs to be developed and ready to conquer these new opportunities. The LCLS instrument concepts have been developed in close consultation with the scientific community through a series of workshops team meetings and focused reviews. In particular, the LUSI project instruments have been identified as meeting the most urgent needs of the scientific community based on the advice of the LCLS Scientific Advisory Committee (SAC) in response to an open call for letters of intent (LOI) from the breadth of the scientific community.

43 PARTICLE ACCELERATORS↗