Search NASA⌕ Search

Engineering topics

Arun Gopalan

Publications and source records attributed to Arun Gopalan.

At least 19 records

Advanced Libya-4 radiometric and atmospheric characterization utilizing MODIS and VIIRS full-scan reflective solar band measurements

The NASA Clouds and the Earth's Radiant Energy System (CERES) project provides observed flux and cloud products to the climate science community. The CERES instruments, along with the MODIS and VIIRS imagers, are onboard the Terra, Aqua, NPP, and NOAA20 satellites. In order to produce seamless multi-platform integrated products, long-term sensor stability and inter-calibration are required. Inter-calibration between sensors within the same sun-synchronous orbit relies on Earth invariant targets because simultaneous nadir overpasses are not possible. To facilitate inter-calibration efforts, the CERES Imager and Geostationary Calibration Group (IGCG) has improved the Libya-4 target characterization. Improvements include full scan angle characterization to enable daily observations, clear-sky identification using individual scan angle dynamic spatial homogeneity thresholds, and atmospheric corrections. The water vapor correction was found to be effective across the full scan, whereas the ozone and aerosol corrections were less effective. The atmospheric-corrected normalized radiance temporal fluctuations are similar across scan angles, spectral bands, and between the MODIS and VIIRS imagers, suggesting that the fluctuations are a result of the natural variability of the Libya-4 surface reflectance. The Libya-4 surface variability is more than likely caused by changes in the prevailing winds that alter sand dune orientation and resulting shadows. The full-scan-imager atmosphere and angle corrected reflected solar band radiance trend standard errors are between 0.6% and 1.0%, and for near-nadir observations, are between 0.5% and 0.8%. The advanced characterization suggests that the Libya-4 short-term surface reflectance anomalies may need to be considered for imager stability monitoring and inter-calibration efforts.

Libya-4 Pseudo-invariant Calibration Site↗

Additional Characterization of Dome-C to Improve its Use as an Invariant Visible Calibration Target

Dome-C is a recommended CEOS invariant target that has been utilized by the calibration community for several decades for monitoring onboard sensor calibration systems as well radiometric inter-comparisons. Dome-C is a high-altitude Earth target located on the East Antarctic interior plateau, which has a permanent bright, flat, and homogeneous snow-covered surface with little aerosol, cloud cover, snowfall, and water vapor burden. This paper describes angular directional models for characterizing the Dome-C top-of-atmosphere (TOA)radiances as a function of cosine solar zenith angle for pre-solstice and post-solstice conditions. The 0.86-μm channel Dome-C reflectance decreases over the summer due to snow metamorphosisis not observed by the visible channels. Coinciding Terra and AquaMODIS Dome-C reflectance showed occasional inter-annual anomalies when compared against the deep convective cloud and Libya-4 invariant targets observations. Further characterization of the Dome-C reflectances with the Dome-C surface broadband albedo, Antarctic Oscillation(AAO) index, and ozone concentration values were evaluated. A strong correlation with ozone was found for the 0.55-μm and 0.65-μm MODIS channels. The monthly Dome-C reflectances were linearly regressed with ozone to derive the ozone correction coefficients. The uncertainty in the Aqua-and Terra-MODIS Dome-C trends was reduced by half after applying ozone corrections to both the 0.55-μm and 0.65-μm channelTOA observations.

David R Doelling↗

Response Versus Scan-Angle Assessment of MODIS Reflective Solar Bands in Collection 6.1 Calibration

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments onboard the Aqua and Terra satellites have been operated for nearly two decades, producing high-quality earth observation data sets suitable for a broad range of scientific studies regarding the earth’s land, ocean, and atmospheric processes. The high radiometric accuracy of MODIS reflective solar band (RSB) calibration has also served as benchmark measurements for on-orbit cross-calibration studies. As the two MODIS instruments have operated well beyond their design lifespan of six years, the measurements from the onboard calibrators alone become inadequate to characterize the sensor’s response at all scan angles, as evinced by long-term drifts observed at certain scan positions of the Aqua-MODIS 0.64- and 0.86-μm bands in Collection 6 (C6) data set. The latest MODIS Level 1B C6.1 data set incorporates earth-view response trending from invariant desert sites as supplemental inputs to characterize the scan-angle calibration dependencies for all RSB. This article presents a deep convective cloud (DCC)-based calibration approach for an independent evaluation of the MODIS RSB response versus scan-angle (RVS) performance in C6.1. The long-term calibration stability and RVS differences in C6.1 have been significantly improved for Aqua-MODIS RSB. The observed RVS differences of more than 2% in Aqua-MODIS C6 bands 1 and 2 have been reduced to within 1% in C6.1. Some RSBs of Terra-MODIS have suffered temporal drifts up to ~2% and calibration shifts up to 3%, particularly around 2016 when the Terra satellite entered into safe mode. The DCC approach has been found very effective in tracking the on-orbit RVS changes over time.

Clouds and the Earth’s Radiant Energy System (CERE↗

The Inter-Calibration of the DSCOVR EPIC Imager 2 with Aqua-MODIS and NPP-VIIRS

The Deep Space Climate Observatory (DSCOVR) Earth Polychromatic Imaging Camera (EPIC) continuously observes the illuminated disk from the Lagrange-1 point. The EPIC sensor was designed to monitor the diurnal variation of ozone, clouds, aerosols, and vegetation, especially those features that benefit from observation near-backscatter conditions. The EPIC sensor does not contain any onboard calibration systems. This study describes the inter-calibration of EPIC channels 5 (0.44 μm), 6 (0.55 μm), 7 (0.68 μm), and 10 (0.78 μm) with respect to Aqua-MODIS and NPP-VIIRS. The calibration is transferred using coincident ray-matched reflectance pairs over all-sky tropical ocean (ATO) and deep convective cloud (DCC) targets. A robust and automated image-alignment technique based on feature matching was formulated to improve the navigation quality of the EPIC images. The EPIC V02 dataset exhibits improved navigation over V01. Because the visible channels display similar spatial features, a single visible channel can be used to co-register the remaining visible bands. The VIIRS-referenced EPIC ATO and DCC ray-matched calibration coefficients are within 0.3%. The EPIC four-year calibration trends based on VIIRS are within 0.15%/year. The MODIS-based EPIC calibration coefficients were compared against the Geogdzhayev and Marshak 2018 published calibration coefficients and are found to be within 1.6%.

DSCOVR↗

TPSAS-NF1676L-13108-DND

Explore the source record for details and available documents.

David Robert Doelling↗

TPSAS-NF1676L-19788-DND

The calibration of the historical AVHRR visible channels has always been hindered by the degrading NOAA satellite orbits. The complete AVHRR record spans over three decades making it useful for cloud, aerosol, and land use climate studies. Studies that monitor long-term changes in these properties require climate quality calibration. The AVHRR sensors do not have any onboard visible calibration, unlike the IR channels. Many AVHRR post-launch calibration methods have been published. Some of these are based on the pseudo invariant targets such as desert and polar ice and others employ direct calibration transfer from a well-calibrated sensor such as MODIS. Most historical studies only employed only one method and reconciling calibration differences from multiple studies was difficult. This study employs multiple calibration approaches, which are then merged according to their individual uncertainty. Since the visible spectral response functions are similar across AVHRR sensor and that the morning and afternoon orbits usually degrade in the same manner, an afternoon and morning orbiter during the MODIS era is chosen as the reference AVHRR sensor. The reference AVHRR sensor is inter-calibrated with the Aqua-MODIS Collection 6 standard using simultaneous nadir overpass (SNO) radiance pairs. Three pseudo invariant target approaches are utilized, deserts, polar ice and deep convective clouds. These sites are characterized using reference AVHRR reflectances as a function of solar zenith angle. The multiple calibration approach is then validated with non-reference AVHRR sensor during the MODIS era, using AVHRR and MODIS SNO measurements. For historical AVHRR satellite having consistent calibration across invariant targets then validates the approach. This calibration effort is in sponsored by the NOAA CDR program to provide climate quality visible calibration coefficients to the remote sensing community. Each of the calibration approaches are unique and when utilized in tandem can accurately calibrate the AVHRR record. AVHRR calibration methods cannot rely on repeatable annual orbits for calibration model development. Inconsistent results prompt code and invariant target examinations that cannot be determined using only single method approaches. Results from this study will be presented at the meeting.

David Doelling↗

TPSAS-NF1676L-16988-DND

There has been renewed interest to uniformly recalibrate historical geostationary (GEO) data records to aid in climate monitoring. GEO sensors have annual repeatable angular sampling over a given location. The view angle is fixed and the imaging schedule is usually constant through its lifetime. Given the fact that colocated GEOs are always share the same sub-satellite point and maintain their imaging schedules provides repeatable angular sampling over decades. One of the biggest challenges in transferring a reference sensor calibration using invariant desert targets to another sensor is the accuracy of the bidirectional reflectance distribution function (BDRF). A well-calibrated GEO can be used to predict the daily exoatmospheric radiance model (DERM) over a desert target for a given GMT that is valid for any GEO sensor at the same location. The advantage of this method is that a BRDF is not needed. Another challenge of invariant target calibration is the unique spectra signature of the desert. However, since most GEOs are built in batches, the spectral response functions (SRF) are very similar for most historical GEOs, the spectral band adjustment factor (SBAF) between GEO sensors is much smaller than for MODIS and GEO sensors. Since the water vapor burden over the desert is seasonal, both the TOA and desert surface can be considered invariant for a given day of the year. The reference GEO can be inter-calibrated with MODIS or VIIRS, which have onboard visible calibration using solar diffusers, using other methods, such as ray-matching or deep convective clouds. Also the next generation GEOs will have onboard visible calibration, which will increase the accuracy of this method. Three Meteosats over the Libyan desert will be used to illustrate the DERM method. The reference Meteosat will be inter-calibrated against Aqua-MODIS. The reference GEO DERM will be constructed and used to calibrate the remaining Meteosats. The DERM calibration will be validated by comparing the calibration using Aqua-MODIS ray-matching. Similarly, two GOES sensors using the Sonoran desert will also be highlighted. An uncertainty analysis will also be performed with emphasis on the SBAF, derived over the desert targets using both SCIAMACHY and Hyperion hyper-spectral radiances.

David Doelling↗

Status of the GSICS VIS/NIR DCC Calibration Efforts

This year's goals for the GSICS VIS/NIR group is to finalize the VIS/NIR demonstration product requirements and to process the product for public dissemination provided on the GSICS web page. The GSICS VIS/NIR group members have been working on a unified calibration approach among various agencies. Two calibration methods have been chosen for the visible bands, deep convective clouds (DCC) and lunar invariant targets. To come to consensus across the agencies, each step of the DCC process will be outlined. Brief discussions are to follow to determine any outstanding issues. The presentation will review the DCC calibration process implemented by the CERES calibration team. CERES has already implemented the DCC method across 18 geostationary satellites. The various agencies have taken the framework and optimized the method for their particular geostationary satellite. Several new improvements will be discussed, such as deseasonalization of the DCC reflectances, impact of the bidirectional model, and update frequency.

David Doelling↗

Monitoring the Calibration of the DSCOVR EPIC Instrument’s Visible Cchannels Using MODIS and VIIRS as a Reference

The Earth Polychromatic Imaging Camera (EPIC) instrument aboard the Deep Space Climate Observatory (DSCOVR) satellite has a constant unique view of the sunlit disk of the Earth from the Lagrange-1 (L1) point nearly a million miles away from the Earth. Due to EPIC not having any on-board calibration systems, the ten spectral channels of EPIC must be inter-calibrated using vicarious on-orbit methods, such as ray-matching with well-calibrated low Earth orbiting satellites like the Aqua-MODIS and SNPP-VIIRS radiometers. The recently released EPIC version 3 L1B data has greatly enhanced the residual navigation errors found in prior versions, thereby decreasing the calibration uncertainty in the aforementioned ray-matching calibration techniques. The automated navigation correction used by these ray-matching methods for further improving the EPIC geolocation will be compared with a new navigation correction method utilizing optical flow between the EPIC and MODIS/VIIRS images. The DSCOVR satellite went into safe mode on June 27, 2019 due to an anomaly with the satellite’s attitude control system, but operations recommenced on March 2, 2020. The calibration of the EPIC instrument before it went into safe mode and after it resumed will be analyzed in order to investigate any potential calibration shifts or discontinuities caused by the spacecraft anomaly.

Conor Haney↗

Radiometric Assessment of the First Three Years of the NOAA-20 VIIRS Reflective Solar Bands Calibration

NASA’s Clouds and the Earth’s Radiant Energy System (CERES) SYN1deg Ed4.1 product utilizes geostationary (GEO) satellite measured radiances and retrieved cloud properties to account for the regional diurnal fluctuations in the Earth’s radiant broadband fluxes for times between the CERES measurements gathered from the Aqua (1:30 PM) and Terra (10:30 AM) sun-synchronous satellites. In CERES Edition 4 products, a global uniformity in the cloud properties and computed surface fluxes across the GEO satellite domains is maintained by scaling the radiance observations from more than twenty GEO visible imagers in the CERES record to a common radiometric reference scale, i.e., Aqua-MODIS. With the new-generation GEO (Himawari-8/9 and GOES-16/17) imagers having multiple reflective solar bands (RSB) that are spectrally similar to those of VIIRS, the CERES Imager and Geostationary Calibration Group (IGCG) is preparing to use NOAA-20 VIIRS as the reference imager for maintaining the radiometric uniformity across the GEO imager constellation. Given the recent Aqua satellite anomaly, this transition may happen sooner than the projected date of Aqua’s de-orbit. This paper presents an independent performance evaluation of the first three years of the NOAA-20 VIIRS RSB calibration in the NASA VIIRS Land Science Investigator-led Processing System (Land SIPS) L1b Collection 2 dataset. The temporal radiometric stability is assessed using multiple invariant Earth targets, including tropical deep convective clouds and the Saharan desert. The invariant target anisotropic reflectance at the top of atmosphere was modeled using five years of stable satellite observations acquired from the previous VIIRS instrument onboard the Suomi National Polar-orbiting Partnership (S-NPP) satellite. The anisotropic corrections are essential for detecting temporal trends with a high statistical confidence. In addition, the radiometric consistency between the RSB of the two VIIRS instruments will be evaluated.

Rajendra Bhatt↗

Langley Automated Sensor Inter-calibration System (LASICS): Open Access Tools for Satellite Imager Inter-Calibration

Satellite imager calibration teams are tasked with maintaining stable measurement records to facilitate reliable monitoring of geophysical parameters and ensure dependable input for weather forecast models. Satellite imagers are neither uniformly calibrated nor radiometrically scaled to a common reference. Consistent inter-calibration between various earth-orbiting satellite imager pairs is a critical step in the creation of seamless earth-scene reflectance data records over time for input to higher level algorithms that retrieve earth system climate-sensitive properties. Each imager inherently by virtue of its optics (and associated properties like Spectral Response etc.) will have a unique measurement of the same earth-scene reflected signal. A key part of this is the identification and prediction of events where the imager pairs from their respective earth-orbits view the same stable terrestrial targets with nearly identical viewing and solar geometry. Langley Automated Sensor Inter-calibration System (LASICS) will provide the Earth remote sensing community with a foundation for the harmonization of these remote sensing records by the development of an intuitive, user-friendly, interactive web-based open access service that will leverage, an existing extensive and ever-growing database of earth-imager channel spectral response functions, on-demand capabilities for computation and visualization of spectral band adjustment factors using a variety of external hyper-spectral earth observation sources (e.g. SCIAMACHY, GOME-2 for VIS and IASI, AIRS for IR) and a variety of Solar Irradiance Spectra.

Arun Gopalan↗

Radiometric Assessment of the First Three Years of the NOAA-20 VIIRS Reflective Solar Bands Calibration

NASA’s Clouds and the Earth’s Radiant Energy System (CERES) SYN1deg Ed4.1 product utilizes geostationary (GEO) satellite measured radiances and retrieved cloud properties to account for the regional diurnal fluctuations in the Earth’s radiant broadband fluxes for times between the CERES measurements gathered from the Aqua (1:30 PM) and Terra (10:30 AM) sun-synchronous satellites. In CERES Edition 4 products, a global uniformity in the cloud properties and computed surface fluxes across the GEO satellite domains is maintained by scaling the radiance observations from more than twenty GEO visible imagers in the CERES record to a common radiometric reference scale, i.e., Aqua-MODIS. With the new-generation GEO (Himawari-8/9 and GOES-16/17) imagers having multiple reflective solar bands (RSB) that are spectrally similar to those of VIIRS, the CERES Imager and Geostationary Calibration Group (IGCG) is preparing to use NOAA-20 VIIRS as the reference imager for maintaining the radiometric uniformity across the GEO imager constellation. Given the recent Aqua satellite anomaly, this transition may happen sooner than the projected date of Aqua’s de-orbit. This paper presents an independent performance evaluation of the first three years of the NOAA-20 VIIRS RSB calibration in the NASA VIIRS Land Science Investigator-led Processing System (Land SIPS) L1b Collection 2 dataset. The temporal radiometric stability is assessed using multiple invariant Earth targets, including tropical deep convective clouds and the Saharan desert. The invariant target anisotropic reflectance at the top of the atmosphere was modeled using five years of stable satellite observations acquired from the previous VIIRS instrument onboard the Suomi National Polar-orbiting Partnership (S-NPP) satellite. The anisotropic corrections are essential for detecting temporal trends with high statistical confidence. In addition, the radiometric consistency between the RSB of the two VIIRS instruments will be evaluated.

Rajendra Bhatt↗

Langley Automated Sensor Inter-calibration System (LASICS): Open Access Tools for Satellite Imager Inter- Calibration

Satellite imager calibration teams are tasked with maintaining stable measurement records to facilitate reliable monitoring of geophysical parameters and ensure dependable input for forecast models. Satellite imagers are neither uniformly calibrated nor radiometrically scaled to a common reference standard. Consistent inter-calibration between various earth-orbiting satellite imager pairs is a critical step in the creation of seamless earth-scene reflectance data records over time for input to higher level algorithms that retrieve earth system climate-sensitive properties. Each imager inherently by virtue of its optics (and associated properties like spectral response etc.) and orbit will have a unique measurement of the same earth-scene reflected signal. A key part of this is the computationally efficient and optimal identification and prediction of science opportunities where the imager pairs from the irrespective earth-orbits near-simultaneously view the same stable terrestrial targets with nearly identical viewing and solar geometry.

Arun Gopalan↗

The Radiometric Scaling of the MODIS and VIIRS Imagers to a Common Reference and Stability Analysis for the Next Edition of CERES Products

The NASA CERES project has provided the climate quality observed TOA and computed surface fluxes to the scientific community. CERES uses MODIS and VIIRS imagers to retrieve cloud properties needed to convert Terra, Aqua, NPP, and NOAA-20 CERES footprint radiance observations into fluxes. The imagers are also used to radiometrically scale the geostationary sensors (GEO) radiances to the imager calibration reference to ensure that the GEO derived cloud properties and broadband TOA fluxes are consistent in both space and time. Both the imager and GEO retrieved cloud properties are used to compute the surface fluxes. The CERES imager and GEO calibration team uses ray-matched radiance pairs to radiometrically scale the SNPP and NOAA-20 VIIRS sensors to the Aqua-MODIS calibration reference. The radiometric scaling is further validated using geostationary imagers as transfer radiometers. The team will rely primarily on deep convective clouds to monitor the imager channel calibration stability and to correct for short term calibration drifts. The DSCOVR satellite was launched on February 25, 2015 and orbits around the L1 Lagrange point directly between the Earth and the sun. The EPIC sensor contains no onboard calibration systems. However, multiple inter-calibration studies have shown that the EPIC imager is very stable in time. The excellent radiometric stability of EPIC allows the use of EPIC observations as a stable reference to validate both the short term drift corrections of the imagers, as well as to validate the radiometric scaling factors between them. Examples of the imager relative calibration using EPIC before and after radiometric scaling will be shown along with the results from the use of invariant targets to remove imager calibration drifts.

DSCOVR-EPIC↗