Search NASAāŒ• Search

Engineering topics

Asa-Awuku, Akua (ORCID:0000000203548368)

Publications and source records attributed to Asa-Awuku, Akua (ORCID:0000000203548368).

Organic Acid Aerosol Measurements from the Mount Airy Site for CoURAGE

This study investigates the prevalence and distribution of organic acid aerosols in a rural environment using filter-based measurements collected in Mount Airy, Maryland, during the CoURAGE campaign from March 19th through June 12th 2025. PM2.5 filters quantify a range of organic acids commonly associated with secondary organic aerosol formation and atmospheric oxidation processes. Each filter was collected using a 15 LPM sampler and was extracted in ultrapure Millipore water (>18 MĪ©), allowing water-soluble organic acids to be extracted into solution for analysis. The extracts were then examined using a Waters Acquity I-Class PLUS liquid chromatography system coupled to a Bruker Maxis-II ultra-high-resolution Q-TOF mass spectrometer with electrospray ionization, providing high-sensitivity detection and separation of target compounds. Concentrations of several key organic acids were quantified, including acetic, propionic, pyruvic, butyric, oxalic, isovaleric, valeric, malonic, maleic, succinic, glutaric, malic, adipic, and citric acids. These findings contribute to ongoing efforts to understand regional aerosol composition and their impacts on aerosol-cloud interactions.

Acetic acid↗

CCN Measurements at Urban Site during CoURAGE

Cloud condensation nuclei (CCN) measurements were collected during CoURAGE from March - June 2025 at the BSEC urban atmospheric chemistry supersite (39.32057 N, 76.6246 W). CCN number concentrations (# cm-3) were obtained at a frequency of 1 second using a cloud condensation nuclei counter (CCN-100, Droplet Measurement Technologies). The CCN counter was operated in stepping mode, measuring CCN over a range of supersaturations from 0.2 to 1.0%. The settings of the instrument were set such that the supersaturation increased in increments of 0.2% up to the maximum supersaturation, and then decreased in increments of 0.2% down to the minimum supersaturation in a repeating cycle. The supersaturation of the instrument was calibrated weekly using ammonium sulfate. The weekly calibrated supersaturation values have been applied to the data. Data during transitions between supersaturation values were removed and replaced with a value of -999. Transitions are defined as the first 210 seconds after a new supersaturation value to ensure the instrument has stabilized following a change in supersaturation. Data were also flagged with a value of -999 if there were concerns with the function of the instrument, specifically the presence of alarm codes, fogging of the optical particle counter (1st stage monitor > 0.4 V), or a sheath to sample flow ratio outside the expected range (< 9 or > 11).

CCN number density↗