Search NASA⌕ Search

Engineering topics

Asaadi, J. [Texas U., Arlington]

Publications and source records attributed to Asaadi, J. [Texas U., Arlington].

Measurement of muon neutrino charged-current quasielasticlike cross section using off-axis NuMI beam at ICARUS

This paper presents the first neutrino cross-section measurement from the ICARUS detector at Fermilab, using Neutrinos at the Main Injector (NuMI) beam data collected from two beam operation periods corresponding to 2.5 × 10 20 protons-on-target in neutrino beam mode. The signal is defined by events with no pions produced in the final state, a topology dominated by charged-current quasielasticlike signatures. The measurement is reported as flux-averaged differential cross sections as functions of kinematic variables that provide sensitivity to the complex nuclear effects that often dominate the systematic uncertainty budgets of neutrino oscillation measurements. Specifically, this work reports cross sections in two angular variables—the angle of the outgoing lepton and the opening angle between the lepton and leading proton—and two variables characterizing the kinematic imbalance between the muon and proton in the plane transverse to the incoming neutrino. These results are compared against predictions from a variety of neutrino event generators, with p values calculated between the extracted cross sections and each prediction. Overall, the predictions agree with the data; however, the current budget of uncertainties does not yet provide sufficient discriminating power to favor a specific model.

Abd Alrahman, F. [Houston U.]↗

Characterizing the energy resolution of the MicroBooNE LArTPC at the MeV scale using monoenergetic features of $^{208}$Tl decays

A detailed understanding of the capabilities and fidelity of low-energy reconstruction is crucial for taking advantage of MeV-scale neutrino physics opportunities in liquid argon time projection chambers (LArTPCs). This study presents a measurement of the resolution of reconstructed energy in the MicroBooNE LArTPC at $\approx 1.5$ MeV. The characterization is performed using monoenergetic signals generated by $2.614$ MeV $γ$-rays from $^{208}$Tl decays undergoing pair production in the detector. The resolution is found to be ($7.52 \pm 0.78 \text{(stat)} \pm 0.92 \text{(syst)}$)%. This value is consistent with the MicroBooNE simulation prediction of ($9.70 \pm 0.65 \text{(stat)}$)% at the $1.6 σ$ level. This study represents the first ever measurement of LArTPC energy resolution at the MeV scale and provides a pathway for monoenergetic energy calibrations in future experiments using LArTPC detectors.

Abratenko, P. [Tufts U.]↗

Enhanced Ionization Charge Identification in the Short-Baseline Neutrino Program Neutrino Detectors with Deep Neural Networks

We present a deep neural net-based region of interest detection method (DNN ROI) for signal processing in the liquid argon time projection chambers of the Short-Baseline Neutrino (SBN) Program, SBND and ICARUS. DNN ROI addresses limitations of the traditional wire-by-wire thresholding algorithm by leveraging the full two-dimensional detector readout and cross-plane matching information. To account for detector performance variations, we explore training with augmented samples. We find that DNN ROI outperforms the traditional method in both low-level ROI identification performance and high-level reconstruction metrics for high-energy cosmic and accelerator neutrino interaction products, while also being more robust against detector variations, with or without sample augmentation.

Abratenko, P. [Tufts U.]↗

DC Cryogenic Modeling of Open-Source SkyWater 130 nm MOSFETs at 77 K Using BSIM4

Cryogenic applications in high-energy physics (HEP) demand reliable, low-power CMOS electronics capable of operating at liquid nitrogen temperatures (77 K). The open-source SkyWater 130nm (SKY130) CMOS process has previously been shown to operate at temperatures as low as 4 K making it a promising candidate for HEP applications. In this work, we characterize and model SKY130 low-threshold voltage transistors at 77 K, which is a temperature commonly used in modeling applications for liquid argon detectors. DC characteristic measurements were performed at both room temperature and liquid nitrogen temperature. We created a cryogenic modeling approach to produce a SPICE-compatible, isothermal BSIM4-based model for select transistor sizes at 77 K. The resulting model agrees with data at 77 K with an average error on the order of 20% (relative RMS) and shows no dependence on drain voltage. Due to the open-source nature of SKY130, we have made our models publicly available on Github. We hope this work will continue the trend for democratizing circuit design at cryogenic temperatures in high-energy physics by enabling open access to accurate cryogenic CMOS device models at 77 K.

Beall, F. [Texas U., Arlington]↗

Scintillation light calibrations, systematic uncertainties, and triggering efficiency in the MicroBooNE detector

Scintillation light, produced alongside ionisation charge from particle interactions, plays a critical role in liquid argon time projection chamber (LArTPC) detectors. A detailed understanding of its production and detection mechanisms is essential for robust calibration, systematic uncertainty evaluation, and physics analysis. This article describes the MicroBooNE light simulation, light-based triggering schemes, photomultiplier tube gain calibration, light response stability, and light-based systematic uncertainties over the course of five years of data collection. In addition, we present a measurement of scintillation light triggering efficiency, focusing on the lowest-light regime relevant to rare-event searches and low-energy neutrino interactions. Finally, we discuss two notable observations in MicroBooNE's data, both reported here for the first time: an approximately 50% decline in MicroBooNE's light yield over time, concentrated in the first two years of running; and a higher than expected O(200 kHz) rate of single photoelectron noise. The results presented provide an important benchmark of long-term light detection performance in LArTPC neutrino detectors.

Abratenko, P. [Tufts U.]↗

First search for sterile neutrino oscillation leading to $ν_μ$ disappearance in the Booster Neutrino Beam at ICARUS

We present a search for muon neutrino disappearance in the Booster Neutrino Beam (BNB) at Fermilab using the ICARUS detector. Neutrino interactions identified as muon neutrinos interacting with argon nuclei via the charged current interaction and having only a muon and at least one proton in the final state (1$μ$Np) have been selected from data collected in 2022-2023 (ICARUS Run 2) and compared with a simulation-based expectation. In the context of a fit to a two-neutrino approximation of the sterile 3+1 model, including the impact of systematic uncertainty from the flux, neutrino interaction, and detector models, we find no statistically significant muon neutrino disappearance at the ICARUS baseline of 600 meters from the BNB target. Corresponding 90% C.L. exclusion contours in $Δm^2_{41}$ - sin$^22θ_{μμ}$ space are presented. This is the first oscillation analysis produced by ICARUS exposed to the BNB. We note that the analysis is systematics limited due to large unconstrained uncertainties from the flux and interaction models. In future joint analyses, data from ICARUS and the SBND detector, exposed to the BNB at 110 meters from target, will be combined to provide significant constraint of these uncertainties, enabling a robust, world-leading two-detector analysis.

Alrahman, F. Abd [Houston U.]↗

Measurement of three-dimensional inclusive muon-neutrino charged-current cross sections on argon with the MicroBooNE detector

We report the measurement of the triple-differential cross section d 3 σ/dE vis d cos(θ μ )dP μ for inclusive muon-neutrino charged-current scattering on argon. This measurement utilizes data from 6.4 x 10 20 protons on target of exposure collected using the MicroBooNE liquid argon time projection chamber located along the Fermilab Booster Neutrino Beam with a mean neutrino energy of approximately 0.8 GeV. The mapping from reconstructed kinematics to truth quantities is validated within uncertainties by comparing the distribution of reconstructed hadronic energy in data to that of the model prediction in different muon scattering angle bins after applying a conditional constraint from the muon momentum distribution in data. The success of this validation provides confidence that the energy transfer in the MicroBooNE detector is well-modeled within simulation uncertainties, enabling a reliable unfolding to a triple-differential cross section defined at the nominal neutrino flux over muon momentum, muon scattering angle, and visible neutrino energy. This validation not only supports accurate cross-section extraction, but also establishes a critical foundation for tuning interaction models used in future neutrino oscillation measurements. The unfolded measurement covers an extensive phase space, providing a wealth of information useful for future liquid argon time projection chamber experiments measuring neutrino oscillations. Comparisons against a number of commonly used model predictions are included and their performance in different parts of the available phase-space is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data-driven model validation for neutrino-nucleus cross section measurements

Neutrino-nucleus cross section measurements are needed to improve interaction modeling to meet the precision needs of neutrino experiments in efforts to measure oscillation parameters and search for physics beyond the Standard Model. We review the difficulties associated with modeling neutrino-nucleus interactions that lead to a dependence on event generators in oscillation analyses and cross section measurements alike. We then describe data-driven model validation techniques intended to address this model dependence. The method relies on utilizing various goodness-of-fit tests and the correlations between different observables and channels to probe the model for defects in the phase space relevant for the desired analysis. These techniques shed light on relevant mismodeling, allowing it to be detected before it begins to bias the cross section results. We compare more commonly used model validation methods which directly validate the model against alternative ones to these data-driven techniques and show their efficacy with fake data studies. These studies demonstrate that employing data-driven model validation in cross section measurements represents a reliable strategy to produce robust results that will stimulate the desired improvements to interaction modeling.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗