Search NASA⌕ Search

Engineering topics

Asner, D.

Publications and source records attributed to Asner, D..

Spatial and temporal evaluations of the liquid argon purity in ProtoDUNE-SP

Liquid argon time projection chambers (LArTPCs) rely on highly pure argon to ensure that ionization electrons produced by charged particles reach readout arrays. ProtoDUNE Single-Phase (ProtoDUNE-SP) was an approximately 700-ton liquid argon detector intended to prototype the Deep Underground Neutrino Experiment (DUNE) Far Detector Horizontal Drift module. It contains two drift volumes bisected by the cathode plane assembly, which is biased to create an almost uniform electric field in both volumes. The DUNE Far Detector modules must have robust cryogenic systems capable of filtering argon and supplying the TPC with clean liquid. This paper will explore comparisons of the argon purity measured by the purity monitors with those measured using muons in the TPC from October 2018 to November 2018. A new method is introduced to measure the liquid argon purity in the TPC using muons crossing both drift volumes of ProtoDUNE-SP. For extended periods on the timescale of weeks, the drift electron lifetime was measured to be above 30 ms using both systems. A particular focus will be placed on the measured purity of argon as a function of position in the detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The track-length extension fitting algorithm for energy measurement of interacting particles in liquid argon TPCs and its performance with ProtoDUNE-SP data

This paper introduces a novel track-length extension fitting algorithm for measuring the kinetic energies of inelastically interacting particles in liquid argon time projection chambers (LArTPCs). The algorithm finds the most probable offset in track length for a track-like object by comparing the measured ionization density as a function of position with a theoretical prediction of the energy loss as a function of the energy, including models of electron recombination and detector response. The algorithm can be used to measure the energies of particles that interact before they stop, such as charged pions that are absorbed by argon nuclei. The algorithm's energy measurement resolutions and fractional biases are presented as functions of particle kinetic energy and number of track hits using samples of stopping secondary charged pions in data collected by the ProtoDUNE-SP detector, and also in a detailed simulation. Additional studies describe the impact of the dE/dx model on energy measurement performance. The method described in this paper to characterize the energy measurement performance can be repeated in any LArTPC experiment using stopping secondary charged pions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First measurement of the total inelastic cross section of positively charged kaons on argon at energies between 5.0 and 7.5 GeV

ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV/𝑐 beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each beam momentum setting was measured to be 380 ± 26 mbarns for the 6 GeV/𝑐 setting and 379 ± 35 mbarns for the 7 GeV/𝑐 setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a Modular Ton-Scale Pixel-Readout Liquid Argon Time Projection Chamber

The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements and provide comparisons to detector simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DUNE Far Detector Vertical Drift Technology. Technical Design Report

DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise. In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered. This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.

47 OTHER INSTRUMENTATION↗

Measurement of branching-fraction ratios and CP asymmetries in B± → DCP±K± decays at Belle and Belle II

Abstract We report results from a study ofB ± → DK ± decays followed byDdecaying to theCP-even final stateK + K − and CP-odd final state$$ {K}_S^0{\pi}^0 $$ K S 0 π 0 , whereDis an admixture ofD 0 and$$ {\overline{D}}^0 $$ D ¯ 0 states. These decays are sensitive to the Cabibbo-Kobayashi-Maskawa unitarity-triangle angleϕ 3 . The results are based on a combined analysis of the final data set of 772×10 6 $$ B\overline{B} $$ B B ¯ pairs collected by the Belle experiment and a data set of 198×10 6 $$ B\overline{B} $$ B B ¯ pairs collected by the Belle II experiment, both in electron-positron collisions at the Υ(4S) resonance. We measure the CP asymmetries to be$$ \mathcal{A} $$ A CP+ = (+12.5±5.8±1.4)% and$$ \mathcal{A} $$ A CP− = (−16.7±5.7±0.6)%, and the ratios of branching fractions to be$$ \mathcal{R} $$ R CP+ = 1.164±0.081±0.036 and$$ \mathcal{R} $$ R CP− = 1.151±0.074±0.019. The first contribution to the uncertainties is statistical, and the second is systematic. The asymmetries$$ \mathcal{A} $$ A CP+ and$$ \mathcal{A} $$ A CP− have similar magnitudes and opposite signs; their difference corresponds to 3.5 standard deviations. From these values we calculate 68.3% confidence intervals of (8.5 ° <ϕ 3 < 16.5 ° ) or (84.5 ° <ϕ 3 < 95.5 ° ) or (163.3 ° <ϕ 3 < 171.5 ° ) and 0.321 B< 0.465.

Physics↗

Search for charged-lepton flavor violation in Υ(2S) → ℓ∓τ± (ℓ = e, μ) decays at Belle

Abstract We report a search for the charged-lepton flavor violation in Υ(2S) →ℓ ∓ τ ± (ℓ=e, μ) decays using a 25 fb −1 Υ(2S) sample collected by the Belle detector at the KEKBe + e − asymmetric-energy collider. We find no evidence for a signal and set upper limits on the branching fractions ($$ \mathcal{B} $$ B ) at 90% confidence level. We obtain the most stringent upper limits:$$ \mathcal{B} $$ B (Υ(2S)→ μ ∓ τ ± )<0.23×10 −6 and$$ \mathcal{B} $$ B (Υ(2S)→ e ∓ τ ± )<1.12×10 −6 .

Physics↗