Search NASA⌕ Search

Engineering topics

Asryan, G.

Publications and source records attributed to Asryan, G..

Photoproduction of η mesons off the proton for 1.2 < E γ < 4.7GeV using CLAS at Jefferson Laboratory

Photoproduction cross sections are reported for the reaction $\gamma p\to p\eta$ using energy-tagged photons and the CLAS spectrometer at Jefferson Laboratory. The $\eta$ mesons are detected in their dominant charged decay mode, $\eta\to \pi^+\pi^-\pi^0$, and results on differential cross sections are presented for incident photon energies between 1.2 and 4.7 GeV. These new $\eta$ photoproduction data are consistent with earlier CLAS results but extend the energy range beyond the nucleon resonance region into the Regge regime. The normalized angular distributions are also compared with the experimental results from several other experiments, and with predictions of $\eta$ MAID\,2018 and the latest solution of the Bonn-Gatchina coupled-channel analysis. Differential cross sections $d\sigma/dt$ are presented for incident photon energies $E_\gamma > 2.9$ GeV ($W > 2.5$ GeV), and compared with predictions which are based on Regge trajectories exchange in the $t$-channel (Regge models). Overall, the data confirm the expected dominance of $\rho$, $\omega$ vector-meson exchange in an analysis by the Joint Physics Analysis Center.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extraction of Beam-Spin Asymmetries from the Hard Exclusive π + Channel off Protons in a Wide Range of Kinematics

We have measured beam-spin asymmetries to extract the $\sin\phi$ moment $A_{LU}^{\sin\phi}$ from the hard exclusive $\vec{e} p \to e^\prime n \pi^+$ reaction above the resonance region, for the first time with nearly full coverage from forward to backward angles in the center-of-mass. The $A_{LU}^{\sin\phi}$ moment has been measured up to 6.6 GeV$^{2}$ in $-t$, covering the kinematic regimes of Generalized Parton Distributions (GPD) and baryon-to-meson Transition Distribution Amplitudes (TDA) at the same time. The experimental results in very forward kinematics demonstrate the sensitivity to chiral-odd and chiral-even GPDs. In very backward kinematics where the TDA framework is applicable, we found $A_{LU}^{\sin\phi}$ to be negative, while a sign change was observed near 90$^\circ$ in the center-of-mass. The unique results presented in this paper will provide critical constraints to establish reaction mechanisms that can help to further develop the GPD and TDA frameworks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The CLAS12 Central Time-of-Flight system

The Central Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system consists of a hermetic barrel of 48 scintillation counters at a radius of 25 cm from the beamline. The wedge-shaped counters are 3.4 cm wide, 3.0 cm thick, and 90 cm long, and span a range of polar angles relative to the center of the nominal target location from roughly 35° to 125°. The counters reside in the 5-T field of the CLAS12 superconducting solenoid. The bars are read out via bent light guides 1 m long on the upstream end of the counters and 1.6 m long on the downstream end. The phototubes are shielded by a multi-layer dynamical magnetic shield system to reduce the local fringe fields in the range from 400 G to 1000 G down to the level of 0.2 G at the location of the photocathodes. The average effective time resolution of the counters is 80 ps.

47 OTHER INSTRUMENTATION↗

The CLAS12 forward electromagnetic calorimeter

The CLAS12 Forward Detector includes six independent lead-scintillator electromagnetic sampling calorimeters to provide the primary electron trigger and extend the CLAS12 detection capability to photons and neutrons. Each calorimeter package consists of two modules, the legacy Electromagnetic Calorimeter (EC) previously used in the CLAS detector, and a new pre-shower calorimeter (PCAL) located in front of the EC to extend the total detector radiation length, in order to fully absorb the electromagnetic showers induced by electrons with energies up to 12 GeV. Both calorimeters use a novel triangular hodoscope geometry with stereo readout. The PCAL uses an upgraded design to provide the high spatial resolution necessary for reconstructing π 0 and η decays, and neutrons with high efficiency. Here, this paper treats the design, construction, and calibration of the PCAL and the preliminary combined performance of both detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗