Search NASA⌕ Search

Engineering topics

Atkinson, David A.

Publications and source records attributed to Atkinson, David A..

Collection, release, and detection of analytes with polymer composite sampling materials

A unique fiber core sampler composition, related systems, and techniques for designing, making, and using the same are described. The sampler is used to interface with existing field instrumentation, such as Ion Mobility Spectrometer (IMS) equipment. Desired sampler characteristics include its: stiffness/flexibility; thermal mass and conductivity; specific heat; trace substance collection/release dependability, sensitivity and repeatability; thickness; reusability; durability; stability for thermal cleaning; and the like. In one form the sampler has a glass fiber core with a thickness less than 0.3 millimeter that is coated with a polymer including one or more of: polymeric organofluorine, polyimide, polyamide, PolyBenzlmidazole (PBI), PolyDiMethylSiloxane (PDMS), sulfonated tetrafluoroethylene (PFSA) and Poly(2,6-diphenyl-p-phenylene Oxide) (PPPO). Multiple polymer coatings with the same or different polymer types may be included, core/substrate surface functionalization utilized, and/or the core/substrate may be at partially filled with thermally conductive particles.

Addleman, Raymond S.↗

Collaborative Research and Development Program on Explosive Detection Technology

In September 2013, at the 6th Permanent Coordinating Group Meeting between the U.S Department of Energy (DOE) and the French Institut de Radioprotection et de Sureté Nucléaire (IRSN), France expressed an interest in bilateral cooperation with the United States because its newly revised regulations that require enhanced explosives detection capabilities at nuclear and radiological facilities. In the ensuing years, PNNL (DOE/NNSA) and IRSN sought to identify an area of collaboration within explosives detection that would leverage the specific technical strengths of each organization. Based upon awareness of each other’s technical acumen gleaned from the scientific literature on explosives detection, it was clear that specific organizations within each nation could provide the needed expertise to enable enhancement of explosives detection through a collaborative development effort. The French lnstitut Saint-Louis was determined to be an optimal partner for IRSN to develop a collaboration with DOE/NNSA using PNNL’s detection team in this effort. Thus, the dialog was started between the technical experts at each organization to define where complementary expertise in explosives detection could be best leveraged. The technical plans and objectives of this project were sound with promising results. In the end, the joint action sheet was not implemented. The challenge with executing the project was in the complexity of getting a signed agreement between DOE, IRSN and ISL. Most of the obstacles surrounded the ability to protect intellectual property and obtain an agreement which included all of the parties. At a high level, this report documents the interactions and attempt to develop a cooperative framework for explosives detection development from FY 2014 through FY 2020.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-Contact Vapor Detection of Illicit Drugs via Atmospheric Flow Tube-Mass Spectrometry

Real-time, non-contact detection of illicit drugs is a desirable goal for the interdiction of these controlled substances, but the relatively low vapor pressures of such species present a challenge for trace vapor detection technologies. The introduction of atmospheric flow tube-mass spectrometry (AFT-MS), which has previously been demonstrated to detect gas-phase analytes at low parts-per-quadrillion levels for explosives and organophosphorus compounds, also enables the potential for non-contact drug detection. With AFT-MS, direct vapor detection of cocaine and methamphetamine from ~5 µg residues at room temperature is demonstrated herein. Furthermore, thermal desorption of low- to sub-picogram levels of cocaine, methamphetamine, fentanyl, and heroin is observed via AFT-MS using a carrier flow rate of several L/min of air. These low levels can permit non-contact sampling through collection of vapor, effectively preconcentrating the analyte before desorption and analysis. Quantitative evaluation of the thermal desorption approach has yielded limits of detection (LODs) on order of 10 fg for cocaine and fentanyl, 100 fg for methamphetamine, and 1.6 pg for heroin. The LOD for heroin was lowered to 200 fg by using tributyl phosphate as a dopant to form a proton-bound heterodimer with heroin. When used with AFT-MS, the intentional formation of specific drug-dopant adducts has the potential to enhance detection limits and selectivity of additional drug species. Species that are prone to form adducts present a challenge to analysis, but that difficulty can be overcome by the intentional addition of a dopant. Molecules unlikely to form adducts will remain essentially unimpacted, but the adduct-forming species will interact with the dopant to compress the analyte signal into a single peak. This approach would be valuable in the application of non-contact screening for illicit substances via vapor collection followed by thermal desorption for analysis.

methamphetamine, cocaine, heroin, fentanyl, atmosp↗

Collection, release, and detection of analytes with polymer composite sampling materials

A unique fiber core sampler composition, related systems, and techniques for designing, making, and using the same are described. The sampler is used to interface with existing field instrumentation, such as Ion Mobility Spectrometer (IMS) equipment. Desired sampler characteristics include its: stiffness/flexibility; thermal mass and conductivity; specific heat; trace substance collection/release dependability, sensitivity and repeatability; thickness; reusability; durability; stability for thermal cleaning; and the like. In one form the sampler has a glass fiber core with a thickness less than 0.3 millimeter that is coated with a polymer including one or more of: polymeric organofluorine, polyimide, polyamide, PolyBenzlmidazole (PBI), PolyDiMethylSiloxane (PDMS), sulfonated tetrafluoroethylene (PFSA) and Poly(2,6-diphenyl-p-phenylene Oxide) (PPPO). Multiple polymer coatings with the same or different polymer types may be included, core/substrate surface functionalization utilized, and/or the core/substrate may be at partially filled with thermally conductive particles.

36 MATERIALS SCIENCE↗

Collection, release, and detection of analytes with polymer composite sampling materials

A unique fiber core sampler composition, related systems, and techniques for designing, making, and using the same are described. The sampler is used to interface with existing field instrumentation, such as Ion Mobility Spectrometer (IMS) equipment. Desired sampler characteristics include its: stiffness/flexibility; thermal mass and conductivity; specific heat; trace substance collection/release dependability, sensitivity and repeatability; thickness; reusability; durability; stability for thermal cleaning; and the like. In one form the sampler has a glass fiber core with a thickness less than 0.3 millimeter that is coated with a polymer including one or more of: polymeric organofluorine, polyimide, polyamide, PolyBenzlmidazole (PBI), PolyDiMethylSiloxane (PDMS), sulfonated tetrafluoroethylene (PFSA) and Poly(2,6-diphenyl-p-phenylene Oxide) (PPPO). Multiple polymer coatings with the same or different polymer types may be included, core/substrate surface functionalization utilized, and/or the core/substrate may be at partially filled with thermally conductive particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method for detecting organophosphorus compounds and illicit drugs

A method is disclosed for detecting organophosphorus compounds and illicit drugs using an ion detector. A vapor sample containing at least one analyte and at least one dopant is ionized. A proton-bound adduct ion is formed between the analyte and the dopant in a reaction region defined between the ionization source and the ion detector.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of Inorganic Salt-Based Homemade Explosives (HME) by Atmospheric Flow Tube–Mass Spectrometry

Using a commercial mass spectrometer interfaced with an atmospheric flow tube (AFT) allowed detection of a variety of inorganic compounds used as oxidizers in homemade explosives at picogram levels. The AFT provides reaction times between 3-5 seconds with flows of 6 L/min, enabling detection levels, after thermal desorption, similar to those previously demonstrated for RDX vapors in the low parts-per-quadrillion range. The thermal desorption of chlorate and perchlorate salts resulted in the production of the corresponding anions which have higher electron affinities than the nitrate reactant ions. A dielectric barrier discharge, used as the ionization source, produced the nitrate reactant ions. In some instances, the molecular salt formed adducts with the nitrate, chlorate, and/or perchlorate anions, giving insight into the original identity of the salt cation. Urea nitrate, guanidine nitrate, and potassium nitrate were also detected as adducts with the nitrate reactant ion. Direct room-temperature vapor detection of urea nitrate and hydrogen peroxide, which have relatively high vapor pressures compared to the other salts in this study, is also demonstrated. Room-temperature vapor detection of chlorate and perchlorate salts is possible by the addition of a dilute acid which converts the salt into a more volatile acidic form. A discussion of the instrumentation, methods used, and the ionization chemistry is provided.

chlorate, perchlorate, nitrate, detection, hydroge↗

Bayesian Integration and Characterization of Composition C-4 Plastic Explosives Based on Time-of-Flight Secondary Ion Mass Spectrometry and Laser Ablation-Inductively Coupled Plasma Mass Spectrometry

Key elements regarding the use of non-radioactive ionization sources will be presented as related to explosives detection by mass spectrometry and ion mobility spectrometry. Various non-radioactive ionization sources will be discussed along with associated ionization mechanisms pertaining to specific sample types.

Bayesian integration↗

Improved explosive collection and detection with rationally assembled surface sampling materials

Sampling and detection of trace explosives is a key analytical process in modern transportation safety. In this work we have explored some of the fundamental analytical processes for collection and detection of trace level explosive on surfaces with the most widely utilized system, thermal desorption IMS. The performance of the standard muslin swipe material was compared with chemically modified fiberglass cloth. The fiberglass surface was modified to include phenyl functional groups. When compared to standard muslin, the phenyl functionalized fiberglass sampling material showed better analyte release from the sampling material as well as improved response and repeatability from multiple uses of the same swipe. The improved sample release of the functionalized fiberglass swipes resulted in a significant increase in sensitivity. Various physical and chemical properties were systematically explored to determine optimal performance. The results herein have relevance to improving the detection of other explosive compounds and potentially to a wide range of other chemical sampling and field detection challenges.

Explosive detection↗

Method for selective detection of explosives in mass spectrometer or ion mobility spectrometer at parts-per-quadrillion level

A method for selective detection of volatile and non-volatile explosives in a mass spectrometer or ion mobility spectrometer at a parts-per-quadrillion level without preconcentration is disclosed. The method comprises the steps of ionizing a carrier gas with an ionization source to form reactant ions or reactant adduct ions comprising nitrate ions (NO.sub.3.sup.-); selectively reacting the reactant ions or reactant adduct ions with at least one volatile or non-volatile explosive analyte at a carrier gas pressure of at least about 100 Ton in a reaction region disposed between the ionization source and an ion detector, the reaction region having a length which provides a residence time (tr) for reactant ions therein of at least about 0.10 seconds, wherein the selective reaction yields product ions comprising reactant ions or reactant adduct ions that are selectively bound to the at least one explosive analyte when present therein; and detecting product ions with the ion detector to determine presence or absence of the at least one explosive analyte.

47 OTHER INSTRUMENTATION↗

Atmospheric pressure ionization of chlorinated ethanes in ion mobility spectrometry and mass spectrometry

This study investigates the APCI mechanisms associated with chlorinated ethanes in an attempt to define conditions under which unique pseudo-molecular adducts, in addition to chloride ion, can be produced for analytical measurements using IMS and MS. The ionization chemistry of chlorinated compounds typically leads to the detection of only the halide ions. Using molecular modeling, which provides insights into the ion formation and relative binding energies, predictions for the formation of pseudo-molecular adducts are postulated. Predicted structures of the chloride ion with multiple hydrogens on the ethane backbone was supported by the observation of specific pseudo-molecular adducts in IMS and MS spectra. With the proper instrumental conditions, such as short reaction times and low temp.

Atmospheric Pressure Ionization↗

Direct Real-Time Detection of Vapors from Explosive Compounds

The real-time detection of vapors from low volatility explosives including PETN, tetryl, RDX and nitroglycerine along with various compositions containing these substances is demonstrated. This was accomplished with an atmospheric flow tube (AFT) using a non-radioactive ionization source and coupled to a mass spectrometer. Direct vapor detection was demonstrated in less than 5 seconds at ambient temperature without sample pre-concentration. The several seconds of residence time of analytes in the AFT provides a significant opportunity for reactant ions to interact with analyte vapors to achieve ionization. This extended reaction time, combined with the selective ionization using the nitrate reactant ions (NO3- and NO3-•HNO3), enables highly sensitive explosives detection. Observed signals from diluted explosive vapors indicate detection limits below 10 ppqv using selected ion monitoring (SIM) of the explosive-nitrate adduct at m/z 349, 378, 284 and 289 for tetryl, PETN, RDX and NG respectively. Also provided is a demonstration of the vapor detection from 10 different energetic formulations, including double base propellants, plastic explosives and commercial blasting explosives using SIM for the NG, PETN and RDX product ions.

atmospheric pressure ionization↗

Comment on "Tunable generation and adsorption of energetic compounds in the vapor phase at trace levels: A tool for testing and developing sensitive and selective substrates for explosive detection"

The evaluation of developed technologies and research on new detection approaches require the ability to generate explosive vapors in the gas phase. In this correspondence, the authors comment on a technical note describing a vaopr generator, discuss safety issues associated with explosives for vapor generators, and provide a concise review of vapor generators for explosive compounds. Approaches to measuring or monitoring the output of a vapor generators are also discussed.

2,4-DNT↗