Search NASA⌕ Search

Engineering topics

Awida, M. H.

Publications and source records attributed to Awida, M. H..

Search for non-virialized axions with 3.3-4.2 $\mu$eV mass at selected resolving powers

The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions compose a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth's motion. We report an exclusion on the local axion dark matter density in narrow flows of $\rho_a \gtrsim 0.03\,\mathrm{GeV/cm^3}$ and $\rho_a \gtrsim 0.004\,\mathrm{GeV/cm^3}$ for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range $3.3-4.2\,\mu\text{eV}$. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonvirialized axion search sensitive to Doppler effects in the Milky Way halo

The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki- Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. Here, we report the results of a non-virialized axion search over the mass range 2.81–3.31 µeV, corresponding to the frequency range 680–800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector’s motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of $\mathscr{O}$(10 -7 )c with 95% confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low frequency, 100–600 MHz, searches with axion cavity haloscopes

We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter experiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-Virialized Axion Search Sensitive to Doppler Effects in the Milky Way Halo

The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion search over the mass range 2.81-3.31 μeV, corresponding to the frequency range 680-800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector's motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of order 10^-7 c with 95% confidence.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark matter axion search using a Josephson Traveling wave parametric amplifier

Here, we describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion–photon couplings above 10 -13 Ge V -1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7–4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.

47 OTHER INSTRUMENTATION↗

Axion Dark Matter

Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Performance Results of the PIP2IT MEBT 200 Ohm Kicker Prototype

The PIP-II project is a program to upgrade the Fermilab accelerator complex. The PIP-II linac includes a 2.1 MeV Medium Energy Beam Transport (MEBT) section that incorporates a unique chopping system to perform arbitrary, bunch-by-bunch removal of 162.5 MHz structured beam. The MEBT chopping system will consist of two identical kickers working together and a beam absorber. One design of two having been proposed has been a 200 Ohm characteristic impedance traveling wave dual-helix kicker driven with custom designed high-speed switches. This paper reports on the first performance results of one prototype kicker built, installed and tested with beam at the PIP-II Injector Test (PIP2IT) facility. The helix deflector design details are discussed. The electrical performance of the high-speed switch driver operating at 500 V bias is presented. Tests performed were chopping beam at 81.25 MHz for microseconds as well as with a truly arbitrary pattern for 550 $\mu$s bursts having a 45 MHz average switching rate and repeating at 20 Hz.

43 PARTICLE ACCELERATORS↗

Multiphysics Analysis of Frequency Detuning in Superconducting RF Cavities for Proton Particle Accelerators

Multiphysics analyses for superconducting cavities are essential in the course of cavity design to meet stringent requirements on cavity frequency detuning. Superconducting RF cavities are the core accelerating elements in modern particle accelerators whether it is proton or electron machine, as they offer extremely high quality factors thus reducing the RF losses per cavity. However, the superior quality factor comes with the challenge of controlling the resonance frequency of the cavity within few tens of hertz bandwidth. In this paper, we investigate how the multiphysics analysis plays a major role in proactively minimizing sources of frequency detuning, specifically; microphonics and Lorentz Force Detuning (LFD) in the stage of RF design of the cavity and mechanical design of the niobium shell and the helium vessel.

43 PARTICLE ACCELERATORS↗

Modeling of Electromagnetic Heating in RF Copper Accelerating Cavities

Electromagnetic heating is a critical issue in normal conducting copper RF cavities that are employed in particle accelerators. With several tens to hundreds of kilowatts dissipated RF power, there must be an effective cooling scheme whether it is water or air based or even a combination of both. In this paper we investigate the electromagnetic heating in multiple cavities that were designed at Fermilab exploring how the electromagnetic and thermal analyses are coupled together to properly design the cooling of such cavities.

43 PARTICLE ACCELERATORS↗

Multipole Effects Study for Project X Front End Cavities

Effects of RF field asymmetry along with multipoles have been studied in Project X front end cavities. One family of half wave resonators operating at 162.5 and two of spoke resonators operating at 325 MHz have been analysed. HWR and spoke res onators unlike elliptical cavities, do not have axial symmetry, hence a quadrupole perturbation to the beam is present. The purpose of this paper is to explain the approach and the calculation method used to understand and overcome the drawbacks due to th e RF field asymmetry.

43 PARTICLE ACCELERATORS↗

Effects of the RF Field Asymmetry in SC Cavities of the Project X

The low-energy SCRF section of CW SC linac of Project X starts from Half Wave Resonators (HWR) having operating frequency f=162.5 MHz, optimal beta= 0.11 and will accelerate the beam from 2 MeV up to 11 MeV. The preliminary analysis of beam dy namics shows that multipole effects caused by asymmetry of RF fields in HWR cavities aren t negligible. In this paper we present the analysis of influence of multipole effects on beam dynamics and discuss the possible solutions how to compensate these eff ects.

43 PARTICLE ACCELERATORS↗

SSR1 HOM Analysis and Measurements

Single spoke resonators (SSR1, β=0.22) are currently under development for Project X at Fermilab. In this paper, extensive Higher Order Mode (HOM) analysis carried out on SSR1 is reported including the simulated R/Q for monopoles, dipoles , and quadrupoles. HOM measurements carried out on several spoke cavities are also reported including the harmonic response and the bead pull measurements. Comparison between the measured R/Q values and the simulated ones are presented.

43 PARTICLE ACCELERATORS↗

Design of SSR1 Single Spoke Resonators for PXIE

The Project X Injector Experiment (PXIE) at Fermilab contains one cryomodule of Single Spoke Resonators operating at 325 MHz with a geometrical beta of 0.2. Two prototypes have been tested successfully at high gradients in the Fermilab Vertica l Test Stand (VTS). We have welded a Stainless Steel helium vessel on the first prototype and tested it in the spoke-dedicated Test Cryostat. With excellent results in hand, an order for ten bare resonators was placed with US industry. A new design for th e helium vessel was developed for these resonators with the main goal of reducing the sensitivity of the resonator to variations of the helium pressure to meet the requirements of PXIE. A new tuner was developed despite the good results of the first proto type. The new design was inevitable due to the different behavior of the resonator in the new helium vessel. Other aspects were improved such as the maintainability of the tuner motor and piezoelectric actuators allowing their replacement from access port s on the cryomodule's vacuum vessel.

43 PARTICLE ACCELERATORS↗

Multipole Effects Study for Project X Front End Cavities

Effects of RF field asymmetry along with multipoles have been studied in Project X front end cavities. One family of half wave resonators operating at 162.5 and two of spoke resonators operating at 325 MHz have been analysed. HWR and spoke res onators unlike elliptical cavities, do not have axial symmetry, hence a quadrupole perturbation to the beam is present. The purpose of this paper is to explain the approach and the calculation method used to understand and overcome the drawbacks due to th e RF field asymmetry.

43 PARTICLE ACCELERATORS↗