Publications and source records attributed to Aydogan, Bulent.

Small Animal IMRT Using 3D-Printed Compensators

Preclinical radiation replicating clinical intensity modulated radiation therapy (IMRT) techniques can provide data translatable to clinical practice. For this work, treatment plans were created for oxygen-guided dose-painting in small animals using inverse-planned IMRT. Spatially varying beam intensities were achieved using 3-dimensional (3D)-printed compensators.

3D PRINTING↗

Technical Note: High temporal resolution characterization of gating response time

Purpose: Low temporal latency between a gating ON/OFF signal and the LINAC beam ON/OFF during respiratory gating is critical for patient safety. Here the authors describe a novel method to precisely measure gating lag times at high temporal resolutions. Methods: A respiratory gating simulator with an oscillating platform was modified to include a linear potentiometer for position measurement. A photon diode was placed at linear accelerator isocenter for beam output measurement. The output signals of the potentiometer and diode were recorded simultaneously at 2500 Hz with an analog to digital converter for four different commercial respiratory gating systems. The ON and OFF of the beam signal were located and compared to the expected gating window for both phase and position based gating and the temporal lag times extracted. Results: For phase based gating, a real-time position management (RPM) infrared marker tracking system with a single camera and a RPM system with a stereoscopic camera were measured to have mean gate ON/OFF lag times of 98/90 and 86/44 ms, respectively. For position based gating, an AlignRT 3D surface system and a Calypso magnetic fiducial tracking system were measured to have mean gate ON/OFF lag times of 356/529 and 209/60 ms, respectively. Conclusions: Temporal resolution of the method was high enough to allow characterization of individual gate cycles and was primary limited by the sampling speed of the data recording device. Significant variation of mean gate ON/OFF lag time was found between different gating systems. For certain gating devices, individual gating cycle lag times can vary significantly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-institutional study to assess adherence to lung stereotactic body radiotherapy planning goals

Purpose: A multi-institutional planning study was performed to evaluate the frequency that current guidelines established by Radiation Therapy Oncology Group (RTOG) protocols and other literature for lung stereotactic body radiotherapy (SBRT) treatments are followed. Methods: A total of 300 patients receiving lung SBRT treatments in four different institutions were retrospectively reviewed. The treatments were delivered using Linac based SBRT (160 patients) or image guided robotic radiosurgery (140). Most tumors were located peripherally (250/300). Median fractional doses and ranges were 18 Gy (8–20 Gy), 12 Gy (6–15 Gy), and 10 Gy (5–12 Gy) for three, four, and five fraction treatments, respectively. The following planning criteria derived from RTOG trials and the literature were used to evaluate the treatment plans: planning target volumes, PTV{sub V} {sub 100} ≥ 95% and PTV{sub V} {sub 95} ≥ 99%; conformality indices, CI{sub 100%} < 1.2 and CI{sub 50%} range of 2.9–5.9 dependent on PTV; total lung-ITV: V{sub 20Gy} < 10%, V{sub 12.5Gy} < 15%, and V{sub 5Gy} < 37%; contralateral lung V{sub 5Gy} < 26%; and maximum doses for spinal cord, esophagus, trachea/bronchus, and heart and great vessels. Populations were grouped by number of fractions, and dosimetric criteria satisfaction rates (CSRs) were reported. Results: Five fraction regimens were the most common lung SBRT fractionation (46%). The median PTV was 27.2 cm{sup 3} (range: 3.8–419.5 cm{sup 3}). For all plans: mean PTV{sub V} {sub 100} was 94.5% (±5.6%, planning CSR: 69.8%), mean PTV{sub V} {sub 95} was 98.1% (±4.1%, CSR: 69.5%), mean CI{sub 100%} was 1.14 (±0.21, CSR: 79.1%, and 16.5% within minor deviation), and mean CI{sub 50%} was 5.63 (±2.8, CSR: 33.0%, and 28.0% within minor deviation). When comparing plans based on location, peripherally located tumors displayed higher PTV{sub V} {sub 100} and PTV{sub V} {sub 95} CSR (71.5% and 71.9%, respectively) than centrally located tumors (61.2% and 57.1%, respectively). Overall, the planning criteria were met for all the critical structure such as lung, heart, spinal cord, esophagus, and trachea/bronchus for at least 85% of the patients. Conclusions: Among the various parameters that were used to evaluate the SBRT plans, the CI{sub 100%} and CI{sub 50%} were the most challenging criteria to meet. Although the CSRs of organs at risk were higher among all cases, their proximity to the PTV was a significant factor.

60 APPLIED LIFE SCIENCES↗

Verification of dose distribution for volumetric modulated arc therapy total marrow irradiation in a humanlike phantom

Purpose: Volumetric modulated arc therapy (VMAT) treatment planning studies have been reported to provide good target coverage and organs at risk (OARs) sparing in total marrow irradiation (TMI). A comprehensive dosimetric study simulating the clinical situation as close as possible is a norm in radiotherapy before a technique can be used to treat a patient. Without such a study, it would be difficult to make a reliable and safe clinical transition especially with a technique as complicated as VMAT-TMI. To this end, the dosimetric feasibility of VMAT-TMI technique in terms of treatment planning, delivery efficiency, and the most importantly three dimensional dose distribution accuracy was investigated in this study. The VMAT-TMI dose distribution inside a humanlike Rando phantom was measured and compared to the dose calculated using RapidArc especially in the field junctions and the inhomogeneous tissues including the lungs, which is the dose-limiting organ in TMI. Methods: Three subplans with a total of nine arcs were used to treat the planning target volume (PTV), which was determined as all the bones plus the 3 mm margin. Thermoluminescent detectors (TLDs) were placed at 39 positions throughout the phantom. The measured TLD doses were compared to the calculated plan doses. Planar dose for each arc was verified using mapcheck. Results: TLD readings demonstrated accurate dose delivery, with a median dose difference of 0.5% (range: -4.3% and 6.6%) from the calculated dose in the junctions and in the inhomogeneous medium including the lungs. Conclusions: The results from this study suggest that RapidArc VMAT technique is dosimetrically accurate, safe, and efficient in delivering TMI within clinically acceptable time frame.

61 RADIATION PROTECTION AND DOSIMETRY↗

Total Marrow Irradiation With RapidArc Volumetric Arc Therapy

Purpose: To develop a volumetric arc therapy (VMAT)-total marrow irradiation (TMI) technique for patients with hematologic malignancies. Methods and Materials: VMAT planning was performed for 6 patients using RapidArc technology. The planning target volume consisted of all the bones in the body from the head to the mid-femur, excluding the extremities, except for the humerus, plus a 3.0-mm margin. The organs at risk included the lungs, heart, liver, kidneys, bowels, brain, eyes, and oral cavity. The VMAT-TMI technique consisted of three plans: the head and neck, the chest, and the pelvis, each with three 330{sup o} arcs. The plans were prescribed to ensure, at a minimum, 95% planning target volume dose coverage with the prescription dose (percentage of volume receiving dose of {>=}12 Gy was 95%). The treatments were delivered and verified using MapCheck and ion chamber measurements. Results: The VMAT-TMI technique reported in the present study provided comparable dose distributions with respect to the fixed gantry linear accelerator intensity-modulated TMI. RapidArc planning was less subjective and easier, and, most importantly, the delivery was more efficient. RapidArc reduced the treatment delivery time to approximately 18 min from 45 min with the fixed gantry linear accelerator intensity-modulated TMI. When the prescription dose coverage was reduced to 85% from 95% and the mandible and maxillary structures were not included in the planning target volume as reported in a tomotherapy study, a considerable organ at risk dose reduction of 4.2-51% was observed. The average median dose for the lungs and lenses was reduced to 5.6 Gy from 7.2 Gy and 2.4 Gy from 4.5 Gy, respectively. Conclusion: The RapidArc VMAT technique improved the treatment planning, dose conformality, and, most importantly, treatment delivery efficiency. The results from our study suggest that the RapidArc VMAT technology can be expected to facilitate the clinical transition of TMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Linear Accelerator-Based Intensity-Modulated Total Marrow Irradiation Technique for Treatment of Hematologic Malignancies: A Dosimetric Feasibility Study

Purpose: To investigate the dosimetric feasibility of linear accelerator-based intensity-modulated total marrow irradiation (IM-TMI) in patients with hematologic malignancies. Methods and Materials: Linear accelerator-based IM-TMI treatment planning was performed for 9 patients using the Eclipse treatment planning system. The planning target volume (PTV) consisted of all the bones in the body from the head to the mid-femur, except for the forearms and hands. Organs at risk (OAR) to be spared included the lungs, heart, liver, kidneys, brain, eyes, oral cavity, and bowel and were contoured by a physician on the axial computed tomography images. The three-isocenter technique previously developed by our group was used for treatment planning. We developed and used a common dose-volume objective method to reduce the planning time and planner subjectivity in the treatment planning process. Results: A 95% PTV coverage with the 99% of the prescribed dose of 12 Gy was achieved for all nine patients. The average dose reduction in OAR ranged from 19% for the lungs to 68% for the lenses. The common dose-volume objective method decreased the planning time by an average of 35% and reduced the inter- and intra- planner subjectivity. Conclusion: The results from the present study suggest that the linear accelerator-based IM-TMI technique is clinically feasible. We have demonstrated that linear accelerator-based IM-TMI plans with good PTV coverage and improved OAR sparing can be obtained within a clinically reasonable time using the common dose-volume objective method proposed in the present study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Normal Tissue Complication Probability Modeling of Acute Hematologic Toxicity in Cervical Cancer Patients Treated With Chemoradiotherapy

Purpose: To test the hypothesis that increased pelvic bone marrow (BM) irradiation is associated with increased hematologic toxicity (HT) in cervical cancer patients undergoing chemoradiotherapy and to develop a normal tissue complication probability (NTCP) model for HT. Methods and Materials: We tested associations between hematologic nadirs during chemoradiotherapy and the volume of BM receiving {>=}10 and 20 Gy (V{sub 10} and V{sub 20}) using a previously developed linear regression model. The validation cohort consisted of 44 cervical cancer patients treated with concurrent cisplatin and pelvic radiotherapy. Subsequently, these data were pooled with data from 37 identically treated patients from a previous study, forming a cohort of 81 patients for normal tissue complication probability analysis. Generalized linear modeling was used to test associations between hematologic nadirs and dosimetric parameters, adjusting for body mass index. Receiver operating characteristic curves were used to derive optimal dosimetric planning constraints. Results: In the validation cohort, significant negative correlations were observed between white blood cell count nadir and V{sub 10} (regression coefficient ({beta}) = -0.060, p = 0.009) and V{sub 20} ({beta} = -0.044, p = 0.010). In the combined cohort, the (adjusted) {beta} estimates for log (white blood cell) vs. V{sub 10} and V{sub 20} were as follows: -0.022 (p = 0.025) and -0.021 (p = 0.002), respectively. Patients with V{sub 10} {>=} 95% were more likely to experience Grade {>=}3 leukopenia (68.8% vs. 24.6%, p < 0.001) than were patients with V{sub 20} > 76% (57.7% vs. 21.8%, p = 0.001). Conclusions: These findings support the hypothesis that HT increases with increasing pelvic BM volume irradiated. Efforts to maintain V{sub 10} < 95% and V{sub 20} < 76% may reduce HT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of Temporal Optimization Effects for a Single Fraction of Radiation In Vitro

Purpose: To experimentally validate how temporal modification of the applied dose pattern within a single fraction of radiation therapy affects cell survival. Method and Materials: Using the linear-quadratic model, we have previously demonstrated that the greatest difference in cell survival results from comparing a temporal dose pattern delivering the highest doses during the middle of a fraction and the lowest at the beginning and end ('Triangle') to one with the lowest doses at the middle and the highest at the beginning and end ('V-shaped'). Also, these differences would be greatest in situations with low alpha/beta and large dose/fraction and fraction length. Two low (WiDr, PC-3) and one high (SQ-20B) alpha/beta cell lines were irradiated in six-well plates with 900 cGy over 20 min (900 cGy/20 min), one each with a Triangle and V-shaped dose pattern. WiDr cells were subjected to the same experiments with first 180 cGy/20 min, then 900 cGy/5 min. Cell survival was assessed using the clonogenic assay. Results: At 900 cGy/20 min, irradiation with a V-shaped pattern resulted in an increased survival compared with use of a Triangle pattern of 21.2% for WiDr (p < 0.01), 18.6% for PC-3 (p < 0.025), and 4.7% for SQ-20B cells (p > 0.05). For WiDr cells at 180 cGy/20 min, this increase reduced to 2.7% (p > 0.05) and to -0.8% (p > 0.05) at 900 cGy/5 min. Conclusions: These results verify the assertions of the modeling study in vitro, and imply that the temporal pattern of applied dose should be considered in treatment planning and delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Comparison of Bone Marrow-Sparing Intensity-Modulated Radiotherapy Versus Conventional Techniques for Treatment of Cervical Cancer

Purpose: To compare bone marrow-sparing intensity-modulated pelvic radiotherapy (BMS-IMRT) with conventional (four-field box and anteroposterior-posteroanterior [AP-PA]) techniques in the treatment of cervical cancer. Methods and Materials: The data from 7 cervical cancer patients treated with concurrent chemotherapy and IMRT without BMS were analyzed and compared with data using four-field box and AP-PA techniques. All plans were normalized to cover the planning target volume with the 99% isodose line. The clinical target volume consisted of the pelvic and presacral lymph nodes, uterus and cervix, upper vagina, and parametrial tissue. Normal tissues included bowel, bladder, and pelvic bone marrow (PBM), which comprised the lumbosacral spine and ilium and the ischium, pubis, and proximal femora (lower pelvis bone marrow). Dose-volume histograms for the planning target volume and normal tissues were compared for BMS-IMRT vs. four-field box and AP-PA plans. Results: BMS-IMRT was superior to the four-field box technique in reducing the dose to the PBM, small bowel, rectum, and bladder. Compared with AP-PA plans, BMS-IMRT reduced the PBM volume receiving a dose >16.4 Gy. BMS-IMRT reduced the volume of ilium, lower pelvis bone marrow, and bowel receiving a dose >27.7, >18.7, and >21.1 Gy, respectively, but increased dose below these thresholds compared with the AP-PA plans. BMS-IMRT reduced the volume of lumbosacral spine bone marrow, rectum, small bowel, and bladder at all dose levels in all 7 patients. Conclusion: BMS-IMRT reduced irradiation of PBM compared with the four-field box technique. Compared with the AP-PA technique, BMS-IMRT reduced lumbosacral spine bone marrow irradiation and reduced the volume of PBM irradiated to high doses. Therefore BMS-IMRT might reduce acute hematologic toxicity compared with conventional techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗