Engineering topics
Bacelli, Giorgio
Publications and source records attributed to Bacelli, Giorgio.
Evaluation of predictionless control for wave energy converters.
Abstract not provided.
WEC Array Networked Microgrid Control Design and Energy Storage System Requirements.
Abstract not provided.
Multi-resonant feedback control of a single degree-of-freedom wave energy converter
A multi-resonant wide band controller decomposes the wave energy converter control problem into sub-problems; an independent single-frequency controller is used for each sub-problem. Thus, each sub-problem controller can be optimized independently. The feedback control enables actual time-domain realization of multi-frequency complex conjugate control. The feedback strategy requires only measurements of the buoy position and velocity. No knowledge of excitation force, wave measurements, nor wave prediction is needed. As an example, the feedback signal processing can be carried out using Fast Fourier Transform with Hanning windows and optimization of amplitudes and phases. Given that the output signal is decomposed into individual frequencies, the implementation of the control is very simple, yet generates energy similar to the complex conjugate control.
Model predictive control of parametric excited pitch-surge modes in wave energy converters
A parametric excitation dynamic model is used for a three degrees-of-freedom (3-DOF) wave energy converter. Since the heave motion is uncoupled from the pitch and surge modes, the pitch-surge equations of motion can be treated as a linear time varying system, or a linear system with parametric excitation. In such case the parametric exciting frequency can be tuned to twice the natural frequency of the system for higher energy harvesting. A parametric excited 3-DOF wave energy converter can harvest more power, for both regular and irregular waves, compared to the linear 3-DOF. For example, in a Bretschneider wave, the harvested energy in the three modes is about 3.8 times the energy harvested in the heave mode alone; while the same device produces about 3.1 times the heave mode energy when using a linear 3-DOF model.
Characterizing the dynamic behavior and performance of a scaled prototype point absorber wave energy converter in a large wave flume.
Abstract not provided.
Pseudo-spectral method to control three-degree-of-freedom wave energy converters
The invention provides optimal control of a three-degree-of-freedom wave energy converter using a pseudo-spectral control method. The three modes are the heave, pitch and surge. A dynamic model is characterized by a coupling between the pitch and surge modes, while the heave is decoupled. The heave, however, excites the pitch motion through nonlinear parametric excitation in the pitch mode. The invention can use a Fourier series as basis functions to approximate the states and the control. For the parametric excited case, a sequential quadratic programming approach can be implemented to numerically solve for the optimal control. The numerical results show that the harvested energy from three modes is greater than three times the harvested energy from the heave mode alone. Moreover, the harvested energy using a control that accounts for the parametric excitation is significantly higher than the energy harvested when neglecting this nonlinear parametric excitation term.
WEC Optimization Tool Scoping Report
This report details the background, design, and initial results for wave energy converter design optimization tool. This tool is intended to provide researchers and developers with a means of optimizing existing wave energy converter designs by including realistic dynamics and control algorithms early in the design cycle.
Evaluation of predictionless control for wave energy converters.
Abstract not provided.
Numerical modelling of a point-absorbing WEC model using DualSPHysics coupled with a multiphysics library.
Abstract not provided.
Wave tank and bench-top control testing of a wave energy converter
An increasing number of experiments are being conducted to study the design and performance of wave energy converters. Often in these tests, a real-time realization of prospective control algorithms is applied in order to assess and optimize energy absorption as well as other factors. This paper details the design and execution of an experiment for evaluating the capability of a model-scale WEC to execute basic control algorithms. Model-scale hardware, system, and experimental design are considered, with a focus on providing an experimental setup capable of meeting the dynamic requirements of a control system. To more efficiently execute such tests, a dry bench testing method is proposed and utilized to allow for controller tuning and to give an initial assessment of controller performance; this is followed by wave tank testing. The trends from the dry bench test and wave tank test results show good agreement with theory and confirm the ability of a relatively simple feedback controller to substantially improve energy absorption. Additionally, the dry bench testing approach is shown to be an effective and efficient means of designing and testing both controllers and actuator systems for wave energy converters.
Experimental Testing of a Floating Oscillating Surge Wave Energy Converter
In order to generate a public data set that can be used to validate Wave Energy Converter (WEC) numerical codes, such as WEC-Sim, Sandia National Laboratories led an experimental testing campaign of a 1:33 scale Floating Oscillating Surge Wave Energy Converter (FOSWEC) in the Directional Wave Basin at Oregon State University's Hinsdale Wave Research Laboratory. Testing was performed in two phases; Phase 1 testing was completed in November - December 2015, and Phase 2 testing was completed in May - June 2016. This experimental testing report details the selection and design of a FOSWEC, experimental setup and tests, and overview of the resulting dataset from Phase 1 and Phase 2 testing.
Optimal control of wave energy converters
A wave energy converter and method for extracting energy from water waves maximizes the energy extraction per cycle by estimating an excitation force of heave wave motion on the buoy, computing a control force from the estimated excitation force using a dynamic model, and applying the computed control force to the buoy to extract energy from the heave wave motion. Analysis and numerical simulations demonstrate that the optimal control of a heave wave energy converter is, in general, in the form of a bang-singular-bang control; in which the optimal control at a given time can be either in the singular arc mode or in the bang-bang mode. The excitation force and its derivatives at the current time can be obtained through an estimator, for example, using measurements of pressures on the surface of the buoy in addition to measurements of the buoy position. A main advantage of this approximation method is the ease of obtaining accurate measurements for pressure on the buoy surface and for buoy position, compared to wave elevation measurements.
Structuring the Optimal Output Feedback Control Gain: A Soft Constraint Approach.
Abstract not provided.
Initial results from wave tank test of closed-loop WEC control
This report describes the set up, execution, and some initial results from a series of wave tank tests of a model-scale wave energy converter (WEC) completed in May 2018 at the Navy's Maneuvering and Sea Keeping (MASK) basin. The purpose of these tests was to investigate the implementation and performance of a series of closed-loop WEC power take-off (PTO) controllers, intended to increase energy absorption/generation.
A comparative study on wave prediction for WECs
The idea of acausality for control of a wave energy converter (WEC) is a concept that has been popular since the birth of modern wave energy research in the 1970s. This concept has led to considerable research into wave prediction and feedforward WEC control algorithms. However, the findings in this report mostly negate the need for wave prediction to improve WEC energy absorption, and favor instead feedback driven control strategies. Feedback control is shown to provide performance that rivals a prediction-based controller, which has been unrealistically assumed to have perfect prediction.