Measurement of the Spectral Shape of the $β$-Decay of 137 Xe to the Ground State of 137 Cs in EXO-200 and Comparison with Theory

Herein we report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden nonunique $β$-decay transition 137 Xe ( 7/2 - ) → 137 Cs ( 7/2 + ) . The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultralow background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal to background ratio of more than 99 to 1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden nonunique $β$-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reflectivity and PDE of VUV4 Hamamatsu SiPMs in liquid xenon

Considering reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE . Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 μ m micro-cells conducted with xenon scintillation light ( ~ 175 nm) in liquid xenon. The specular reflectivity at 15 o incidence of three samples of VUV4 SiPMs is found to be 30.4 ± 1.4%, 28.6 ± 1.3%, and 28.0 ± 1.3%, respectively. The PDE at normal incidence differs by ± 8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was further measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.

47 OTHER INSTRUMENTATION↗

Azimuthal asymmetries of back-to-back π ± - ( π 0 , η , π ± ) pairs in e + e - annihilation

This work reports the first observation of azimuthal asymmetries around the thrust axis in e + e – annihilation of pairs of back-to-back charged pions in one hemisphere, and π 0 and η mesons in the opposite hemisphere. These results are complemented by a new analysis of pairs of back-to-back charged pions. The π 0 and η asymmetries rise with the relative momentum z of the detected hadrons as well as with the transverse momentum with respect to the thrust axis. These asymmetries are sensitive to the Collins fragmentation function $H$ $^{1}_{⊥}$ and provide complementary information to previous measurements with charged pions and kaons in the final state. In particular, the η final states will provide additional information on the flavor structure of $H$ $^{1}_{⊥}$. This is the first measurement of the explicit transverse-momentum dependence of the Collins fragmentation function from Belle data. It uses a dataset of 980.4 fb –1 collected by the Belle experiment at or near a center- of-mass energy of 10.58 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of a new structure near 10.75 GeV in the energy dependence of the e + e – → Υ(nS)π + π – (n = 1, 2, 3) cross sections

We report a new measurement of the e + e – → Υ(nS)π + π – (n = 1, 2, 3) cross sections at energies from 10.52 to 11.02 GeV using data collected with the Belle detector at the KEKB asymmetric-energy e + e – collider. We observe a new structure in the energy dependence of the cross sections; if described by a Breit-Wigner function its mass and width are found to be M = (10752.7 ± 5.9$^{+0.7}_{–1.1}$) MeV/c 2 and Γ = (35.5$^{+17.6+3.9}_{–11.3–3.3}$) MeV, where the first error is statistical and the second is systematic. The global significance of the new structure including systematic uncertainty is 5.2 standard deviations. We also find evidence for the e + e – → Υ(1S)π + π – process at the energy 10.52 GeV, which is below the $B\overline{B}$ threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First measurement of the CKM angle Φ 3 with $B^±→ D({K}_{\mathrm{S}}^0π^+π^–π^0)K^±$ decays

We present the first model-independent measurement of the CKM unitarity triangle angle Φ 3 using B ± → D ( \( {K}_{\mathrm{S}}^0 \) π + π – π 0 ) K ± decays, where D indicates either a D 0 or \( \overline{D} \) 0 meson. Measurements of the strong-phase difference of the D → \( {K}_{\mathrm{S}}^0 \) π + π – π 0 amplitude obtained from CLEO-c data are used as input. This analysis is based on the full Belle data set of $772 × 10^6 B$ \( \overline{B} \) events collected at the Υ(4 S ) resonance. We obtain Φ 3 = ( \( {5.7}_{-8.8}^{+10.2} \) ± 3 . 5 ± 5 . 7) ° and the suppressed amplitude ratio r B = 0 . 323 ± 0 . 147 ± 0 . 023 ± 0 . 051. Here the first uncertainty is statistical, the second is the experimental systematic, and the third is due to the precision of the strong-phase parameters measured from CLEO-c data. The 95% confidence interval on Φ 3 is ( – 29 . 7 , 109 . 5) ° , which is consistent with the current world average.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of τ – → π – ν τ e + e – and search for τ – → π – ν τ μ + μ –

We present the first measurements of branching fractions of rare tau-lepton decays, τ – → π – ν τ ℓ + ℓ – (ℓ = e or μ), using a data sample corresponding to 562 fb –1 collected at a center-of-mass energy of 10.58 GeV with the Belle detector at the KEKB asymmetric-energy e + e – collider. The τ – → π – ν τ e + e – decay is observed for the first time with 7.0σ significance. The partial branching fraction determined by the structure-dependent mechanisms mediated by either a vector or an axial-vector current for the mass region M πee > 1.05 GeV/c 2 is measured to be B(τ – → π – ν τ e + e – )[M π – e + e – > 1.05 GeV/c 2 ] = (5.90 ± 0.53 ± 0.85 ± 0.11) × 10 –6 , where the first uncertainty is statistical, the second is systematic, and the third is due to model dependence. In the full phase space, due to the different detection efficiencies for the structure-dependent mechanisms mediated by axial-vector and vector currents, the branching fraction varies from B A (τ – → π – ν τ e + e – ) = (1.46 ± 0.13 ± 0.21) × 10 –5 to B V (τ – → π – ν τ e + e – ) = (3.01 ± 0.27 ± 0.43) × 10 –5 , respectively. An upper limit is set on the branching fraction of the τ – → π – ν τ μ + μ – decay, B(τ – → π – ν τ μ + μ – ) < 1.14 × 10 –5 , at the 90% confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the Hamamatsu VUV4 MPPCs for nEXO

In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range 163 K = T = 233 K. At an over voltage of 3.1 ± 0.2 V and at T = 163 K we report a number of Correlated Avalanches (CAs) per pulse in the 1µs interval following the trigger pulse of 0.161±0.005. At the same settings the Dark-Noise (DN) rate is 0.137 ± 0.002 Hz/mm2. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at T = 233 K for a mean wavelength of 189 ± 7 nm. At 3.6 ± 0.2 V and 3.5 ± 0.2 V of over voltage we report a PDE of 13.4 ± 2.6 % and 11 ± 2%, corresponding to a saturation PDE of 14.8 ± 2.8 % and 12.2±2.3%, respectively. Both values are well below the 24 % saturation PDE advertised by Hamamatsu. More generally, the second device tested at 3.5 ± 0.2 V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBKLF SiPMs for the final design of the nEXO detector.

Gallina, G↗

Simulation of charge readout with segmented tiles in nEXO

nEXO is a proposed experiment to search for the neutrino-less double beta decay (0νββ) of 136 Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neural network are developed to distinguish simulated 0νββ signals from backgrounds arising from trace levels of natural radioactivity in the detector materials. These simulations indicate that the nEXO TPC with charge-collection tiles shows promising capability to discriminate the 0νββ signal from backgrounds. Furthermore, the estimated half-life sensitivity for 0νββ decay is improved by 20 32)% with the multi-variate (deep neural network) methods considered here, e sensitivity estimated in the nEXO pre-conceptual design report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗