Search NASA⌕ Search

Engineering topics

Bahk, Seung-Whan

Publications and source records attributed to Bahk, Seung-Whan.

Single-shot, phase-diversity phase retrieval for high-energy beam focal-spot diagnostics

A single-shot, phase-diversity phase-retrieval method is demonstrated for directly characterizing the on-target focal spot at kilojoule energy in the OMEGA 60-beam laser. A 2D holographic grating that introduces diversity focal spots is installed in an existing on-target focal-spot diagnostic to obtain a single-shot diversity focal-spot image. A nonlinear optimization phase-retrieval algorithm with four diversity focal spots is employed to determine modal coefficients for the incident wavefront. The agreement between the measured and calculated focal spots is excellent. Furthermore, this approach can be easily adapted for other high-energy focal-spot diagnostics.

47 OTHER INSTRUMENTATION↗

High average power ultrafast laser technologies for driving future advanced accelerators

Large scale laser facilities are needed to advance the energy frontier in high energy physics and accelerator physics. Laser plasma accelerators are core to advanced accelerator concepts aimed at reaching TeV electron electron colliders. In these facilities, intense laser pulses drive plasmas and are used to accelerate electrons to high energies in remarkably short distances. A laser plasma accelerator could in principle reach high energies with an accelerating length that is 1000 times shorter than in conventional RF based accelerators. Notionally, laser driven particle beam energies could scale beyond state of the art conventional accelerators. LPAs have produced multi GeV electron beams in about 20 cm with relative energy spread of about 2 percent, supported by highly developed laser technology. This validates key elements of the US DOE strategy for such accelerators to enable future colliders but extending best results to date to a TeV collider will require lasers with higher average power. While the per pulse energies envisioned for laser driven colliders are achievable with current lasers, low laser repetition rates limit potential collider luminosity. Applications will require rates of kHz to tens of kHz at Joules of energy and high efficiency, and a collider would require about 100 such stages, a leap from current Hz class LPAs. This represents a challenging 1000 fold increase in laser repetition rates beyond current state of the art. Here, this whitepaper describes current research and outlook for candidate laser systems as well as the accompanying broadband and high damage threshold optics needed for driving future advanced accelerators.

47 OTHER INSTRUMENTATION↗

Phase retrieval using Gaussian basis functions

A wavefront map of arbitrary aperture can be represented by a sum of Gaussian basis functions. Its performance is compared here to other representation methods such as orthonormal polynomials and Fourier modes. Gaussian basis functions can be applied to phase retrieval of high-frequency wavefront maps. Experiments show good agreement with direct measurements by a wavefront sensor. Finally, optimum measurement conditions are discussed based on the statistics of wavefront properties.

47 OTHER INSTRUMENTATION↗

Measurement of chromatic aberrations using phase retrieval

We explore the feasibility of measuring chromatic aberrations using a technique based on phase retrieval, primarily for the purpose of diagnostics on the OMEGA EP laser. A computational model and optimization strategy is described, issues of numerical efficiency are addressed, and the potential limitations of the method are studied using mathematical analysis and Monte Carlo simulations. As a result, the algorithm performs well in simulation and yields encouraging results in a small-scale laboratory experiment.

97 MATHEMATICS AND COMPUTING↗

Analytic phase solutions of three-wave interactions

Closed-form analytic phase solutions of three-wave interactions are presented for the first time. The cases from simple second harmonic generation to most general three wave interactions without any constraints are considered. The phase amplification or deamplification behavior in the phase-sensitive parametric process is illustrated using the results obtained here. The analytic solutions agree with the results from direct numerical integration. The validity range of an approximate phase solution is discussed.

47 OTHER INSTRUMENTATION↗

A highly efficient, 10-J output signal amplifier for ultra-intense all-OPCPA systems

Optical parametric chirped-pulse amplification (OPCPA) using high-energy Nd:glass lasers has the potential to produce ultra-intense pulses (>10 23 W/cm 2 ). We report on the performance of the final high-efficiency amplifier in an OPCPA system based on large-aperture (63 x 63-mm 2 ) partially deuterated potassium dihydrogen phosphate (DKDP) crystals. Here, the seed beam (170 nm, 240 mJ) was provided by the preceding OPCPA stages. The maximum pump-to-signal conversion efficiency of 37% was achieved with a 52-mm-long DKDP crystal and 40-J pump energy at 527 nm due to the flattop super-Gaussian pump beam profile and flat-in-time pulse shape. The 11.8-J output signal was compressed to 19 fs.

42 ENGINEERING↗

Method and apparatus for wavefront sensing

A method for performing optical wavefront sensing includes providing an amplitude transmission mask having a light input side, a light output side, and an optical transmission axis passing from the light input side to the light output side. The amplitude transmission mask is characterized by a checkerboard pattern having a square unit cell of size Λ. The method also includes directing an incident light field having a wavelength λ to be incident on the light input side and propagating the incident light field through the amplitude transmission mask. The method further includes producing a plurality of diffracted light fields on the light output side and detecting, at a detector disposed a distance L from the amplitude transmission mask, an interferogram associated with the plurality of diffracted light fields. The relation is satisfied, where n is an integer greater than zero.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method and apparatus for wavefront sensing

A method for performing optical wavefront sensing includes providing an amplitude transmission mask having a light input side, a light output side, and an optical transmission axis passing from the light input side to the light output side. The amplitude transmission mask is characterized by a checkerboard pattern having a square unit cell of size .LAMBDA.. The method also includes directing an incident light field having a wavelength $ \lamda $ to be incident on the light input side and propagating the incident light field through the amplitude transmission mask. The method further includes producing a plurality of diffracted light fields on the light output side and detecting, at a detector disposed a distance L from the amplitude transmission mask, an interferogram associated with the plurality of diffracted light fields.

47 OTHER INSTRUMENTATION↗

Spatiotemporal control of laser intensity

The controlled coupling of a laser to a plasma has the potential to address grand scientific challenges including reaching the Schwinger limit, developing compact free electron lasers, extending linear colliders to TeV energies, and generating novel light sources for probing electron dynamics within molecules. Currently, many such applications have limited flexibility and poor control over the laser focal volume. Here we present an advanced focusing scheme called a “flying focus” where a chromatic focusing system combined with chirped laser pulses enables a small–diameter laser focus to propagate nearly 100 times its Rayleigh length, while decoupling the speed at which the peak intensity moves from its group velocity. This unprecedented spatiotemporal control over the laser focal volume allows the laser focus to co- or counter–propagate along its axis at any velocity. Experiments validating the concept measured subluminal (-0.09c) to superluminal (39c) focal spot velocities generating a nearly constant peak intensity over 4.5 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method and apparatus for wavefront sensing

A method of measuring characteristics of a wavefront of an incident beam includes obtaining an interferogram associated with the incident beam passing through a transmission mask and Fourier transforming the interferogram to provide a frequency domain interferogram. The method also includes selecting a subset of harmonics from the frequency domain interferogram, individually inverse Fourier transforming each of the subset of harmonics to provide a set of spatial domain harmonics, and extracting a phase profile from each of the set of spatial domain harmonics. The method further includes removing phase discontinuities in the phase profile, rotating the phase profile, and reconstructing a phase front of the wavefront of the incident beam.

47 OTHER INSTRUMENTATION↗

Offner radial group delay compensator for ultra-broadband laser beam transport

Conventional lens-based image relays introduce radial group delay that significantly reduces focal-spot intensity of ultra-broadband short pulses. A direct compensation scheme that can be used with conventional singlet image relays is proposed. The compensation scheme is based on using two negative lenses embedded within an Offner imaging system. The setup allows a single-pass configuration and eliminates the need for polarization switching optics. The performance of this setup is calculated using ray tracing. The compensation improves the spatiotemporal Strehl ratio from 0.02 to 0.97.

Bahk, Seung-Whan↗