Nuclear data covariances are critical input to determine upper sub-critical limits and to design experiments to increase it [Slides]

This presentation discusses how Upper Subcritical Limits (USL) are key parameters to determine operational limits in nuclear criticality safety evaluations. It also discusses an example of plutonium casting operation using tantalum at LANL PF-4. The Whisper tool at Los Alamos relies on many inputs, including covariance data, leading the presentation to ask if an existing benchmark data be used in Whisper to adjust nuclear data and covariances to justify a higher USL. If not, Whisper can be used to help design an optimal new benchmark experiment. The presentation also seeks to determine what the possible impacts are on USL and operational limits for plutonium casting. In conclusion, nuclear data covariances are used for by Whisper for: GSSL adjustment of nuclear data and covariances, identification of most similar existing benchmark experiments to application, simulation of Upper Subcritical Limit of application, and input to optimization techniques for designing most appropriate new benchmark experiment(s) to meet requirements. This requires a complete set of nuclear data covariances, benchmarks and k-effective sensitivity profiles (for both benchmarks and applications). The presentation concludes by asking if end users should trust results that depend on current covariance data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Patchy nuclear chain reactions

Stochastic fluctuations of the neutron population within a nuclear reactor are typically prevented by operating the core at a sufficient power, since a deterministic (i.e., exactly predictable) behavior of the neutron population is required by automatic safety systems to detect unwanted power excursions. In order to characterize the reactor operating conditions at which the fluctuations vanish, an experiment was designed and took place in 2017 at the Rensselaer Polytechnic Institute Reactor Critical Facility. This experiment however revealed persisting fluctuations and striking patchy spatial patterns in neutron spatial distributions. Here we report these experimental findings, interpret them by a stochastic modeling based on branching random walks, and extend them using a “numerical twin” of the reactor core. Consequences on nuclear safety will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

National Criticality Experiments Research Center (NCERC) - capabilities and recent measurements

The National Criticality Experiments Research Center (NCERC) located at the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS) and operated by Los Alamos National Laboratory (LANL) is home to four critical assemblies which are used to support of range of missions, including nuclear criticality safety and nuclear nonproliferation. Additionally, subcritical systems can also be assembled at NCERC. NCERC is providing critical and subcritical experiments valuable to the nuclear data community and experiments performed at NCERC are often published as benchmarks in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. This manuscript will give a broad overview of recent experiments performed at NCERC, upcoming experiments, and why integral measurements are important and useful to the nuclear data community. The four critical assemblies are GODIVA IV, FLATTOP, COMET, and PLANET. GODIVA IV is a cylindrical metal fast burst reactor, the fourth in the GODIVA series that dates back to the 1950’s. FLATTOP is an highly enriched uranium (HEU) or Pu core reflected by natural uranium. COMET and PLANET are vertical lift assemblies, where one half of the reactor can be lifted to the upper half of the reactor to create a critical system. Some recent experiments include various critical intermediate energy assemblies with lead, and subcritical measurements of plutonium reflected by copper, tungsten, and nickel. Work is also underway to make a better measurement of the critical mass of neptunium, using a neptunium sphere surrounded by nickel shells. Additionally, measurements will be performed next year with HEU shells from Rocky Flats. These HEU shells will be stacked together to make larger systems, allowing for a large range of criticality (from subcritical to delayed critical). Other upcoming measurements include an HEU critical assembly sensitive to intermediate energy neutrons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Patchy snapshots of nuclear chain reactions

Stochastic fluctuations of the neutron population within a nuclear reactor are typically prevented by operating the core at a sufficiently high power. This regime, where the evolution of the neutron density is essentially deterministic, is key for automatic protection and safety systems to safely detect unwanted power excursions during an accident, and to rapidly initiate a reactor trip procedure in case it is needed. Recent works, supported by numerical simulations, have however reported that, for large reactors, the branching nature of the fission reactions might induce strongly non-Poissonian patterns in the neutron spatial distribution, and that stochastic fluctuations might still persist at reactor powers close to operating conditions (startup phase). An international program conducted by LANL, IRSN and CEA was therefore setup to experimentally detect and characterize such fluctuations and correlations. An experiment took place in 2017 at the Reactor Critical Facility (RCF) of the Rensselaer Polytechnic Institute (USA). In this paper we will report the main findings of this experimental program, supported by stochastic models and by the development of a dedicated high-fidelity Monte Carlo simulation code. We will in particular describe and explain the strong patchiness in neutron power distributions measured at the RCF, as well as a peculiar ‘blinking’ behavior of the core, and discuss the consequences of these findings on nuclear safety.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Note on the Nomenclature in Neutron Multiplicity Mathematics

The purpose of this technical note is to consolidate the notations used for describing parameters that pertain to neutron multiplicity mathematics relevant to various applications including nonproliferation, international safeguards, and criticality safety among others. The nomenclatures used in these techniques vary widely depending on the origin of the work and their applications. We aim here to consolidate many of the previously used notations in a single document to enhance past, present, and future technical exchanges pertaining to neutron multiplicity. This will help avoid confusion in future publications and will facilitate wider application-independent advancements and utility of peer-reviewed findings. A brief introduction and history of neutron multiplicity counting is presented, followed by a summary of commonly used techniques in a variety of different applications. In each section, we present the notations used in previous publications for the reader’s reference.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of statistical uncertainties in subcritical benchmark measurements: Part II – Measured data

Part I of this work presented an uncertainty approach which incorporates the singles and doubles counting rates determined by the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. This moments-based approach utilizes time correlations between prompt neutrons detections to assess the system multiplication. Additionally, it presented a validation which utilized simulated data generated using a 0-D point-kinetics Monte Carlo code. In Part II, this same method and validation approach is applied to measured data of a subcritical benchmark experiment. These measurements were performed with a 4.5 kg sphere of alpha-phase weapons grade plutonium reflected by copper and/or polyethylene. Finally, the results of 17 configurations are shown including detailed validation for four of the configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of Statistical Uncertainties in Subcritical Benchmark Measurements: Part I - Theory and Simulations

Subcritical neutron noise measurements are often used to determine multiplication of a system with Special Nuclear Material. This work presents an uncertainty approach which incorporates the singles and doubles counting rates determined by the Hage-Cifarelli formalism. This is a moments-based approach which utilizes time correlations between prompt neutrons in order to assess the system multiplication. After the method is described, a validation is presented which utilizes simulated data generated using a 0-D point-kinetics Monte Carlo code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development Of A Novel Genetic Algorithm-based Optimization Method For Design Of Nuclear Criticality Experiments

A new evaluation of isotopic molybdenum total neutron cross section data based on measurements performed at Rensselaer Polytechnic Institute prompted researchers at Rensselaer and Los Alamos National Laboratory (LANL) to design a nuclear criticality experiment for the validation of the data. A novel approach of criticality experiment design employing a genetic algorithm-based optimization technique was developed. The method produced a critical experiment with a cross section sensitivity that exceeded target specifications by an order of magnitude.

59 BASIC BIOLOGICAL SCIENCES↗

NCSP IER 422 CED-3b Documentation

A Subcritical Copper-Reflected α-phase Plutonium (SCRαP) integral benchmark experiment has been designed and measured. In this experiment, multiplication is approximated using correlated neutron data from a detector system consisting of 3He tubes inside high density polyethylene (HDPE). Measurements were performed on various subcritical experimental configurations consisting of a weapons-grade plutonium sphere surrounded by different Cu thicknesses. In addition to the proposed base experimental configurations with Cu, additional configurations were performed with the plutonium ball nested in various thicknesses of interleaved HDPE spherical shells mixed in with the Cu shells. The HDPE is intended to provide fast neutron moderation and reflection, resulting in additional measurements with differing multiplication, spectra, and nuclear data sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pictures from Year Two CNEC and CVT Measurements

Below are all of the pictures for the CNEC and CVT measurements performed at the DAF in July 2016. In total there are 165 pictures. The photos on pages 2-105 were taken during the first week of measurements and the photos on pages 106-165 were taken during the second week of measurements. Many photos are applicable to both sets, which is why it is best to keep the entire set together. For most configurations, a description of the configuration was written on a white board; photos of the measurement setup were taken, then a photo of the white board was taken. For example, the pictures on pages 6-19 (which precede a white board picture on page 20) are of the configuration with Rocky Flats Shells 1-2 surrounded by 4 AmLi sources, which is listed on the white board picture on page 20. In some cases, the white board picture precedes the configuration pictures.

47 OTHER INSTRUMENTATION↗