Search NASA⌕ Search

Engineering topics

Bair, C. H.

Publications and source records attributed to Bair, C. H..

Investigation of loss processes of Tm and Tm,Ho in YAG

The loss of excitation from various manifolds of Tm and Tm,Ho in YAG as a function of temperature and concentration is studied. Two probable loss mechanisms - a Tm up-conversion and a Ho up-conversion - are identified. A 785-nm CW diode laser with 400-nW peak power was focused to a small spot on the sample. The emission from the sample observed at 90 deg was monitored through a monochromator with slits open to 3 mm. Intensity of emission was measured by varying the power of the excitation source using a set of neutral density filters. Power is reported as the percentage of the peak power, and the intensity curves were normalized below 20 percent of transmission. The fact that there is emission above the pump energy indicates an up-conversion from excited manifolds. Nonlinear changes in the intensity of the emission from the Tm 3F4 manifold with the pump power reveals a loss of excitation from this manifold. The linear dependence of the 5I7 manifold emission with pump power at low Tm and high Ho concentrations and the gain of energy in the 5I6 manifold of Ho indicate that the 5I7 manifold loss is due to the coupling of Tm and Ho ions.

Armagan, G.↗

Recent advances in efficient long-life, eye-safe solid state and CO2 lasers for laser radar applications

The key problems in the development of eye-safe solid-state lasers are discussed, taking into account the energy transfer mechanisms between the complicated energy level manifolds of the Tm, Ho, Er ion dopants in hosts with decreasing crystal fields such as YAG or YLF. Optimization of energy transfer for efficient lasing through choice of dopant concentration, power density, crystal field and temperature is addressed. The tailoring of energy transfer times to provide efficient energy extraction for short pulses used in DIAL and Doppler lidar is considered. Recent advances in Pt/SnO2 oxide catalysts and other noble metal/metal oxide combinations for CO2 lasers are discussed. Emphasis is given to the dramatic effects of small quantities of H2O vapor for increasing the activity and lifetime of Pt/SnO2 catalysts and to increased lifetime operation with rare isotope (C-12)(O-18)2 lasing mixtures.

Hess, R. V.↗

Development in tunable solid state lasers with high spectral purity, high efficiency and long lifetime for differential absorption lidar

The paper presents a review of tunable vibronic solid state lasers for DIAL measurements and provides new experimental results for tunable Ti:sapphire lasers, materials development, and spectral bandwidth narrowing through injection control. Pulsed injection control of a Ti:sapphire laser with a 2.5-pm narrow band pulsed dye laser and with another Ti:sapphire laser is demonstrated with nearly complete energy extraction, indicating homogeneous line broadening. The status of tunable solid state lasers in the 1.6-2.3 micron range for DIAL measurements of trace gases, and development trends for lasers with reduced cryogenic cooling needs, are included. The effects of laser gain on optical damage, energy extraction, and amplified spontaneous emission are indicated for several tunable lasers.

Hess, R. V.↗

CO2 DIAL sensitivity studies for measurements of atmospheric trace gases

An analysis is presented of the accuracy of infrared differential absorption lidar (DIAL) measurements of trace constituents in the atmosphere. Expressions are derived for the signal-to-noise ratios applicable in the detection of a signal from a scattering cell for the cases of single-detection heterodyne detection and direct detection. Results of computer simulations of the expectation value of the measured return for various measurement conditions are presented which illustrate the sensitivities of plume measurements for horizontal range-resolved and vertical content measurements of NH3 in heterodyne and direct detection. Advantages for long-range measurements of the use of rare isotope laser frequencies, tuning by collision broadening, and closely spaced on and off frequencies are pointed out.

Brockman, P.↗

Coherent infrared lidar mission and technology needs for measurements of transport and concentration of tropospheric trace species

The science justification and the feasibility of aircraft-based CO2 Doppler lidar measurements of transport between the free troposphere and the stratosphere (or planetary boundary layer) are discussed for a wide range of seasonal and geographic conditions. Ground-based coherent CO2 lidar aerosol scattering experiments using a stable ring resonator (about 50 mJ/pulse) CO2 laser with external injection locking are reported. Comparative studies of injection-locked CO2 laser unstable resonators and master oscillator power amplifiers are reported for future CO2 lidar missions with respect to requirements of pulse energy, duration/shape, frequency chirp, efficiency for heterodyne detection, and combined Doppler lidar and Differential Absorption Lidar missions.

Hess, R. V.↗

Ozone air broadening coefficients in the 9-micron region

Air broadening coefficients and line strengths are reported for selected ozone lines in the 8.8 to 10 micron spectral region. These parameters were obtained from a least squares fit of the Voigt line shape to experimental ozone absorption spectra obtained with a tunable diode laser. Analysis of 11 lines in the nu 1 and 18 lines in the nu 3 band suggest a transition dependent coefficient, although no definitive relationship was identified. The average air broadening coefficient for the nu 1 and nu 3 ozone lines is 0.077 and 0.083 per cm/atm, respectively. The measured line strengths are typically 10% to a factor of 2 larger than those given in the AFGL compilation.

Hoell, J. M.↗

DIAL with heterodyne detection including speckle noise: Aircraft/shuttle measurements of O3, H2O, and NH3 with pulsed tunable CO2lasers

A parametric analysis of DIAL sensitivity with heterodyne detection is presented and comparisons with direct detection are discussed. Examples are given for monitoring vertical distributions of O3, H2O, and NH3 using a ground-, aircraft-, or shuttle-based pulsed tunable CO2 laser DIAL system. Results indicate that maximum sensitivity at minimum laser energy per measurement requires multiple pulse operation with the energy per pulse selected so that the measured photon rate is approximately equal to the detector IF bandwidth. Measurement sensitivities can be maximized and interference effects minimized by fine adjustment of measurement frequencies using the tunability of high pressure lasers. The use of rare isotope lasers minimizes loss due to CO2 atmospheric absorption.

Brockman, P.↗

DIAL with heterodyne detection including speckle noise: Aircraft/shuttle measurements of O3, H2O, and NH3 with pulsed tunable CO2 lasers

Atmospheric trace constituent measurements with higher vertical resolution than attainable with passive radiometers are discussed. Infrared differential absorption lidar (DIAL), which depends on Mie scattering from aerosols, has special advantages for tropospheric and lower stratospheric applications and has great potential importance for measurements from shuttle and aircraft. Differential absorption lidar data reduction involves comparing large amplitude signals which have small differences. The accuracy of the trace constituent concentration inferred from DIAL measurements depends strongly on the errors in determining the amplitude of the signals. Thus, the commonly used SNR expression (signal divided by noise in the absence of signal) is not adequate to describe DIAL measurement accuracy and must be replaced by an expression which includes the random coherent (speckle) noise within the signal. A comprehensive DIAL computer algorithm is modified to include heterodyne detection and speckle noise. Examples for monitoring vertical distributions of O3, H2O, and NH3 using a ground-, aircraft-, or shuttle-based pulsed tunable CO2 laser DIAL system are given.

Brockman, P.↗

High-resolution spectral measurement of the HNO3 5.9-micron band using a tunable diode laser

High resolution spectra in the region of the v(2) band of nitric acid have been obtained for selected portions of the HNO3 spectrum using tunable diode laser techniques. Continuous spectra are presented from 1718.97/cm to 1729.57/cm, with a spectral resolution not greater than 0.001/cm (30 MHz). Absolute line intensities and line positions are presented. Self- and foreign-gas (N2) broadening coefficients were iteratively calculated from the experimental data and were determined to be alpha(a) = 0.74/cm atm and alpha (f) = 0.13/cm atm, respectively.

Bair, C. H.↗

High resolution absorption coefficients for Freon-12

The ultra high resolution absorption coefficients of the Q-branch of Freon-12 obtained with tunable diode laser spectroscopy are presented. Continuous spectra are presented from 1155/cm to 1163/cm, and absolute wavelength calibration was obtained using SO2 spectra as a standard and a 5 cm Ge etalon for relative calibration between SO2 lines. The Freon-12 data obtained at a pressure of 0.05 torr showed a rich and highly structured spectra, but with the exception of three isolated features, collisional broadening reduces the spectra to a structureless continuum for nitrogen pressures greater than 20 torr. The spectra at 1161/cm continue to exhibit structure at atmospheric pressure.

Hoell, J. M.↗

Infrared vibration-rotation spectra of the ClO radical using tunable diode laser spectroscopy

Tunable diode laser spectroscopy is used to measure the infrared vibration-rotation spectra of the ClO radical. The radical is generated in a flow system where a Cl2-He mixture passes through a microwave discharge to dissociate the Cl2. An O3-O2 mixture from an ozone generator is injected into the system downstream of the microwave discharge where O3 combines with Cl to form ClO. By adjusting the gas flow rates to yield an excess of Cl atoms, all the ozone is combined. ClO concentration is measured with UV absorption at 2577 and 2772 A and a deuterium lamp as a continuous source. Total cell pressure is 5.5 torr. The diode laser spectrometer is calibrated with ammonia lines as a reference where possible. The frequency of vibration-rotation lines is expressed as a function of rotational quantum number, fundamental vibrational frequency, and the rotational constants of the upper and lower vibrational states.

Rogowski, R. S.↗

High resolution spectral measurement of the HNO3 11.3-micron band using tunable diode lasers

High resolution spectra in the region of the 2-nu9 band of nitric acid have been obtained for selected portions of the HNO3 spectrum using tunable diode laser techniques. Continuous spectra are presented from 891.25/cm to 898.77/cm, with a spectral resolution less than or equal to 0.001/cm (30 MHz). Absolute line intensities and line positions are presented. Absolute wavelength calibration was obtained by frequency mixing the diode laser with a C(13)O2(16) isotope laser. Self and foreign gas (N2) broadening coefficients were iteratively calculated from the experimental data and were determined.

Brockman, P.↗

Analysis of diffential absorption lidar technique for measurements of anhydrous hydrogen chloride from solid rocket motors using a deuterium fluoride laser

An active optical technique (differential absorption lidar (DIAL)) for detecting, ranging, and quantifying the concentration of anhydrous HCl contained in the ground cloud emitted by solid rocket motors (SRM) is evaluated. Results are presented of an experiment in which absorption coefficients of HCl were measured for several deuterium fluoride (DF) laser transitions demonstrating for the first time that a close overlap exists between the 2-1 P(3) vibrational transition of the DF laser and the 1-0 P(6) absorption line of HCl, with an absorption coefficient of 5.64 (atm-cm) to the -1 power. These measurements show that the DF laser can be an appropriate radiation source for detecting HCl in a DIAL technique. Development of a mathematical computer model to predict the sensitivity of DIAL for detecting anhydrous HCl in the ground cloud is outlined, and results that assume a commercially available DF laser as the radiation source are presented.

Bair, C. H.↗

Measurement of HCl absorption coefficients with a DF laser

Absorption coefficients in the fundamental P-branch of HCl at several DF laser transitions from 2439.02/cm to 2862.87/cm have been measured experimentally. The 2-1 P(3) DF laser transition has been shown to overlap the P(6) HCl-37 absorption line within the halfwidth of an atmospherically broadened line. The absorption coefficient k was measured to be 5.64 plus or minus 0.28/(atm-cm) for a 0.27% mixture of HCl in N2 at a total pressure of 760 torr. A theoretical and experimental comparison of the pressure dependence of k showed that the 2-1 P(3) DF transition lies 1.32 plus or minus 0.15 GHz from the center of the P(6) HCl absorption line. Applications of these results to differential absorption lidar and to heterodyne detection are discussed.

Bair, C. H.↗

Analysis of laser differential absorption remote sensing using diffuse reflection from the earth

A computer model analysis of an infrared laser differential absorption remote sensing technique (DARS) is presented. An infrared laser source operating at two or more wavelengths and a heterodyne detection system are considered to be mounted on either an aircraft or satellite platform to monitor the differential absorption between the laser source and the earth surface. The capability of this technique for measuring gas concentrations in the lower 5 kilometers of the atmosphere is emphasized. Numerical results are presented simulating measurements of vertical burdens of CO, NO, CH4, CO2, and O3. These results indicate that measurements of expected concentrations of these gases can be made with greater than 80% accuracy using realistic laser powers and system parameters.

Seals, R. K., Jr.↗